• 제목/요약/키워드: Quality Control(QC)

검색결과 179건 처리시간 0.03초

해양과학기지 시계열 관측 자료 품질관리 시스템 구축: 국제 관측자료 품질관리 방안 수온 관측 자료 시범적용과 문제점 (Quality Control of Observed Temperature Time Series from the Korea Ocean Research Stations: Preliminary Application of Ocean Observation Initiative's Approach and Its Limitation)

  • 민용침;정진용;장찬주;이재익;정종민;민인기;심재설;김용선
    • Ocean and Polar Research
    • /
    • 제42권3호
    • /
    • pp.195-210
    • /
    • 2020
  • The observed time series from the Korea Ocean Research Stations (KORS) in the Yellow and East China Seas (YECS) have various sources of noise, including bio-fouling on the underwater sensors, intermittent depletion of power, cable leakage, and interference between the sensors' signals. Besides these technical issues, intricate waves associated with background tidal currents tend to result in substantial oscillations in oceanic time series. Such technical and environmental issues require a regionally optimized automatic quality control (QC) procedure. Before the achievement of this ultimate goal, we examined the approach of the Ocean Observatories Initiative (OOI)'s standard QC to investigate whether this procedure is pertinent to the KORS. The OOI QC consists of three categorized tests of global/local range of data, temporal variation including spike and gradient, and sensor-related issues associated with its stuck and drift. These OOI QC algorithms have been applied to the water temperature time series from the Ieodo station, one of the KORS. Obvious outliers are flagged successfully by the global/local range checks and the spike check. Both stuck and drift checks barely detected sensor-related errors, owing to frequent sensor cleaning and maintenance. The gradient check, however, fails to flag the remained outliers that tend to stick together closely, as well as often tend to mark probably good data as wrong data, especially data characterized by considerable fluctuations near the thermocline. These results suggest that the gradient check might not be relevant to observations involving considerable natural fluctuations as well as technical issues. Our study highlights the necessity of a new algorithm such as a standard deviation-based outlier check using multiple moving windows to replace the gradient check and an additional algorithm of an inter-consistency check with a related variable to build a standard QC procedure for the KORS.

XN-9000장비에서 Low Level QC물질에서의 혈소판 수 관리와 용혈에 따른 P-LCR의 변화 (Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000)

  • 심문정;이현아
    • 대한임상검사과학회지
    • /
    • 제50권4호
    • /
    • pp.399-405
    • /
    • 2018
  • 임상검사실에서의 혈소판 수 계산은 지혈이상의 진단과 치료에 필수적이며, 혈소판 수가 적은 경우 혈소판 수혈이 필요하고 항암치료 후 혈소판 수 경과를 모니터링하는데 매우 중요하다. 정도관리는 환자결과를 내보내기 전에 검사실에서 오류를 줄이고 교정하는 과정이며 분절된 적혈구는 혈소판과 크기가 비슷하여 혈소판 수 계산에 영향을 미친다. 검사실에서 내부정도관리low QC물질이 2SD를 벗어난 것을 경험하였고, 지금까지 용혈과 혈소판 지표들과의 관계에 대해 밝혀진 것이 충분하지 않아 연구를 시작하였다. 이에 본 연구에서는 XN CHECK low level QC물질을 이용해 PLT-I, PLT-O, PLT-F 방법간의 혈소판 수치를 비교하였으며, 용혈검체를 만들어 5가지 혈소판지표들에 대해 비교분석 하였다. 그 결과PLT-F방법에서 CV값이 가장 적게 나타났으며, 용혈검체에서 P-LCR 수치가 18.4%에서 31.9%로 증가함을 보였다. 이 연구를 통해 혈소판 수치가 낮은 경우는 PLT-F방법으로 하는 것이 더 정확하며, 검체가 용혈이나 변질이 의심되는 경우 이를 평가할 때 P-LCR을 새로운 지표로 제시하고 있으며, 사람 혈액검체를 이용한 추후 연구가 더 필요할 것이라고 사료된다.

Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC) (Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method)

  • 전준민;허당;김동술
    • 한국대기환경학회지
    • /
    • 제18권6호
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1947-1954
    • /
    • 2021
  • In the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine.

EPS 공법의 파괴사례 및 품질관리 개선방안 (Case Studies of EPS Failure and Quality Control by Site Monitoring)

  • 김호비;주태성;류기정;한태곤;김태경;정종권
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.401-408
    • /
    • 2003
  • EPS(Expanded Polystyrene) has been used in a variety of applications as a solution of difficult soil conditions encountered in construction activities. Although there has been significant worldwide growth in the use of EPS as a lightweight fill material, it has a few failure cases before and after the construction. This paper described the observed failures of EPS structures up In date around the world. Also, method of quality control was proposed for site monitoring.

  • PDF

'프로그램학습성과 및 평가'실천을 위한 모형 개발 및 전략에 대한 연구 (Model Development and Strategy plan for Implementing Program Outcomes and Assessment)

  • 김명랑;윤우영;김동환;정진택
    • 공학교육연구
    • /
    • 제10권4호
    • /
    • pp.29-42
    • /
    • 2007
  • 공학교육인증에 있어서 프로그램학습성과는 공학교육의 질적 향상 정도를 판가름하는 중요한 기준이며 가장 핵심이 되는 부분이다. 한국공학교육인증원은 프로그램학습성과를 공과대학 졸업생들이 졸업과 동시에 반드시 지녀야 하는 핵심 역량 12가지로 규정하고 있으며 인증을 받고자 하는 모든 공학교육프로그램은 전공 관련 지식을 포함하여 이를 달성하기 위한 교육과정을 구축하고 달성 및 지속적인 개선을 하고 있는지의 여부를 보이기를 요구하고 있다. 여기서 프로그램학습성과는 크게 두 가지를 만족시켜야만 하는데첫째, 공학프로그램은 졸업생이 12가지 능력과 자질에 대해 달성하고 졸업함을 보장할 것에 대한 요구와 둘째, 12가지 능력 및 자질을 교육시키는 프로그램의 교육 수준의 지속적인 개선이다. 따라서 본 연구의 목적은 이러한 한국공학교육인증원의 취지에 맞는 평가를 실시하기 위해 프로그램학습성과 평가의 CQI와 QC를 실현을 위해 갖추어야 할 체계인 구축 모형을 소개하고 한국공학교육인증원의 기준에 알맞은 실천전략을 제시하고자 한다.

기후변화 시나리오 자료의 통계적 상세화를 위한 결측자료 보정 기법 개발 (Development of gap filling technique for statistical downscaling of cimate change scenario data)

  • 조재필;김광형;박지훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.16-16
    • /
    • 2019
  • 기후변화 시나리오 및 계절예측 자료를 포함한 기후정보를 수자원 분야에 활용하기 위해서는 기후정보의 시 공간적인 상세화(donwscaling)을 필요로 한다. 상세화의 경우 역학적 상세화와 통계학적 상세화로 구분될 수 있으며, 통계학적 상세화를 위해서는 대상 지역의 기후특성을 대표할 수 있는 장기 관측 자료의 확보가 중요하다. 국내의 경우에는 자동기상관측장비(Automatic Weather System, AWS)와 종관기상관측장비(Automatic Synoptic Observation System, ASOS)로 부터 수집된 기상관측자료를 사용할 수 있으나 기후변화 시나리오의 통계적 상세화를 위해서는 30년 이상의 자료 기간을 포함하는 ASOS 자료가 적합하다. 하지만 개발도상국과 같이 기상관측기반이 열악한 지역에서는 잦은 결측 등으로 인하여 품질이 좋은 관측자료의 획득이 어려운 상황이다. 따라서 본 연구에서는 측이 포함된 장기 기상관측 자료로부터 대상 지역의 기후특성을 재현할 수 있도록 기본적인 QC(Quality Control)을 거쳐 결측 자료를 보완할 수 있는 기법 및 R 기반패키지를 개발하여 적용성을 평가하였다. 개발된 기법의 적용성 평가를 위해서 기상청에서 QC를 통해 제공하고 있는 60개 ASOS 지점의 관측자료 중 강수량과 기온 변수를 사용하였다. 최대 50%까지의 현실적인 결측 패턴을 임의로 생성하기 위해 실제 개발도상국 관측자료의 일단위 결측 패턴을 이용하였다. 자료의 QC는 관측일 누락/중복 및 문자형 관측값 등 기본적인 오류 검사, 기온의 경우 물리적 허용 범위에 대한 검사, 최고기온과 최저기온의 비교 및 계측기 오작동에 의한 동일한 값의 반복 등을 포함한 내적 일치성 검사를 우선적으로 수행한다. 이후 결측값에 대해서 인근 기상관측소와의 상관성 분석 결과를 기반으로 결측값을 채우고, 최종적으로는 다양한 위성자료 및 재분석 자료 중에서 일단위 기후특성의 재현성 평가를 통해 선정된 격자형 자료와의 상관성 분석 결과를 기반으로 결측값을 보정하였다. 기온의 경우는 결측률이 높더라도 월평균 기후특성에 큰 영향을 미치지 않았지만 강수의 경우에는 5% 이상의 결측이 발생하는 경우 월평균 강수량에 영향을 미쳐 지역의 강수량을 과소 추정하는 결과를 보였다. 개발된 QC 기법을 강수 자료에 적용한 결과 월평균 기후특성을 잘 복원하는 결과를 보였지만, 일단위 강우 사상의 재현에 있어서는 미흡한 결과를 보였다.

  • PDF

제조산업 생산성 향상을 위한 QMS 설계 및 구현 (The Design and Implementation of Quality Management System for Manufacturing Industry Productivity)

  • 최성;최우영;정정민;최종진;김택민
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.229-232
    • /
    • 2003
  • 점점 취약해지고 있는 우리의 산업 경쟁력은 WTO 체제의 새로운 무역 질서와 치열해진 품질 및 생산성 경쟁으로 더욱 심한 어려움에 직면하고 있다. 품질 우위를 통한 산업 경쟁력 향상 노력은 기업마다 가지고 있는 공통적인 경영 과제가 되고 있지만 정부와 관련 단체 등의 의욕적인 품질관리(QC : Quality Control)시책과 노력에도 불구하고 이를 통한 가시적 경영 성과는 극히 일부 기업에서만 확인되고 있는 실정이다. 본 연구에서는 이와 같은 QC 적용상의 이론적 과제 해결에 보다 접근하기 위하여 품질관리시스템(QMS : Quality Management System) 을 조직에 적용하는 방법을 제시하였다. 즉 조직에 대한 품질관리가 QMS 체제 구축을 위해서 유용한 수단이 될 수 있음을 보이고, 어떠한 단계로 전개하는가를 단계별로 연구하였다.

  • PDF

Study on the Embedded SPC System Bused on LAN

  • Yin, Jianjun;Yu, Zhonghua;Wu, Zhaotong
    • International Journal of Quality Innovation
    • /
    • 제4권1호
    • /
    • pp.205-212
    • /
    • 2003
  • Statistical Process Control (SPC) is recognized as one of the most important tool of quality control (QC), and is one research focus in order to implement SPC quickly and effectively using computer technology and network environments. This paper proposes the principle and topology of embedded SPC based on the Internet/lntranet, emphatically discusses the embedded data sampling block, embedded network interface and SPC strategy. An example of application is given.