• Title/Summary/Keyword: Quality(0) factor

Search Result 2,412, Processing Time 0.032 seconds

A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters (단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

A Study of Domestic Construction Quality Management Factor Analysis - (using Covariance Structure Model) (국내건설현장 품질경영 요인 분석에 관한 연구(공분산구조모델을 이용))

  • Kim Tae Sung;Koo Il Seob;Lim Nam Gyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.3
    • /
    • pp.29-36
    • /
    • 2005
  • This research has been conducted in order to assess the effects on quality management factor of the construction sites. 30 companies abiding by the 'construction industry law' and 32 companies abiding by the 'housing construction promotion law' have been researched in areas of quality-management environment, quality-management understanding, quality-management education on construction field, quality-system and quality-improvement. This construction quality factors are to realized the anticipated results not only quality level's increasing, but also company's confidence, competitiveness. We were able to obtain participations of 62 questionnaire, and derived statistics by means of SPSS/PC version 10.0. In this study, we find the bottleneck factor for promotion and upgrade quality management factor of the construction sites and suggest a way out of difficulties.

Strain Analysis for Quality Factor oft he Layered Mg0.93Ca0.07TiO3-(Ca0.3Li0.14Sm0.42)TiO3 Ceramics at Microwave Frequencies

  • Cho, Joon-Yeob;Yoon, Ki-Hyun;Kim, Eung-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.3
    • /
    • pp.222-225
    • /
    • 2002
  • Microwave dielectric properties of the layered and functionally graded materials (FGMs) of $Mg_{0.93}Ca_{0.07}TiO_3$ (MCT) and $(Ca_{0.3}Li_{0.14}Sm_{0.42})TiO_3$(CLST) were investigated as a function of the volume ratio of two components. Dielectric constant was decreased with an increase of the volume ratio of MCT which had a lower dielectric constant thant CLST. For the layered FGMs specimens, the difference of thermal expansion coefficients between two components induced thermal strain to dielectric layers, which was confirmed by the plot of ${\Delta}$k (X-ray diffraction peak width0 versus k (scattering vector) using the double-peak Lorentzian function, f(x). Quality factor of the specimens was affected by the thermal strain of dielectric layer, especially MCT layer. For the specimen with the volume ratio of MCT/CLST = 2, the qulaity factor of the specimen showed a minimum value due to the maximum thermal strain fo MCT layer.

Dielectric and Piezoelectric Properties of Low Temperature Sintering PSN-PZI Ceramics with BiFe3 Substitution (BiFe3첨가에 따른 저온소결 PSN-PZT세라믹스의 유전 및 압전 특성)

  • 류주현;정광현;정영호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.492-496
    • /
    • 2004
  • In this study, (0.96 -x)(PSN-PZT)-xBF-0.04 PNW+0.3wt%MnO$_2$+0.6wt%CuO ceramics were fabricated with the variations of the amount of BiFeO$_3$substitution and sintering temperature for the development of modified ceramics which can be sintered in the low temperature($\leq$100$0^{\circ}C$ ), and their microstructural, dielectric and piezoelectric characteristics were investigated. As the amount of BiFeO$_3$ substitution was increased, the density, mechanical quality factor(Q$_{m}$) and electromechanical coupling factor(k$_{p}$) showed the maximum value at each of sintering temperature. At sintering temperature of 98$0^{\circ}C$ and BiFeO$_3$substitution of 2 mol%, the density, dielectric constant and electromechanical coupling factor(k$_{p}$) showed the maximum value of 7.84 g/㎤, 1415 and 0.49, respectively. And at sintering temperature of 95$0^{\circ}C$ and BiFeO$_3$substitution of 3mol%, mechanical quality factor showed the maximum value of 1062. 1062.

A study on the model of homebound senior's meal satisfaction related to the quality of life

  • Lee, Sun-Mee;Joo, Na-Mi
    • Nutrition Research and Practice
    • /
    • v.6 no.4
    • /
    • pp.357-365
    • /
    • 2012
  • This study was conducted to develop a construct model regarding the daily activities, emotional security provided by food, enjoyment of food, level of satisfaction with delivered food, and the quality of life of homebound seniors who benefitted from meal delivery programs. The data were analyzed by SAS 9.2 and the Structural Equation Model (SEM), which was created by Analysis of Moment Structure (AMOS) 5.0 packages. The reliability of the data was confirmed by an exploratory factor analysis and through a Cronbach's alpha coefficient, and the measurement model proved to be appropriate by a confirmatory factor analysis of the measurement model in conjunction with AMOS. The results of the correlations between all the variables showed significant positive correlations (P < 0.05). The path analysis demonstrated that the daily activities (P < 0.01) and the emotional security created by food (P < 0.05) had positive correlations with the foodservice satisfaction (P < 0.05), while the daily activities (P < 0.05), the sense of emotional security made by food (P < 0.05), and food enjoyment (P < 0.05) also presented significant positive correlations with the quality of life. However, the food service satisfaction was shown to directly, but not significantly, affect the quality of life. This revealed that the current meal delivery programs needed to be improved in several directions.

Fear of dentist care and quality of life in dental health in male high school students (일부 남자 고등학생의 치과치료 공포감과 구강건강 삶의 질에 관한 연구)

  • Lee, Jung-Hwa;Lee, Yeong-Ae;Kim, Young-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.6
    • /
    • pp.951-959
    • /
    • 2014
  • Objectives: The purpose of this study was to find out the fear of dentist care, subjective recognition of dental health, and quality of life in the male high school students and to analyze the influencing factors on dental health care. Methods: A self-reported questionnaire was filled out by 243 special high-school in Deagu province from March 3 to March 14, 2014. The questionnaire consisted of general characteristics of the subjects(5 questions), subjective recognition of health and activities to improve health(6 questions), dental fear(20 questions), oral health related quality of life(16 questions). The instrument for dental fear was adapted from measured by Berggren Dental Fear Survey(DFS). A total of 20 DFS questions included treatment avoidance(8 questions), stimulus reaction(6 questions), and physiological reaction(5 questions) and score by Likert 5 scale. Cronbach alpha was 0.974 in the study. Oral health related quality of life was measured by 16 questions of CPQ11-14 for the adolescents by Lau. CPQ11-14 consisted of oral symptoms(4 questions), functional restriction(4 questions), and emotional wellbeing(4 questions). The instrument was score by Likert 5 scale and Cronbach alpha was 0.9354 in the study. Data were analyzed using SPSS 18.0 program for ANOVA and multiple regression analysis. Results: Fear of dentist care showed significant differences in treatment avoidance factor(p<0.001), stimulus reaction factor (p<0.05), and physiological reaction factor(p<0.001). The factors depended on subjective recognition of health and health-improving activities and differences in treatment avoidance factor(p<0.05) and physiological reaction factor(p<0.01). The dental symptoms factors showed significant differences in health recognition(p<0.001), interest in health(p<0.001), alcohol drinking status(p<0.001) and regular meal(p<0.001). While function limit factors showed differences in health recognition (p<0.001), interest in health(p<0.001), smoking(p<0.001), alcohol drinking(p<0.001) and regular meal(p<0.001). Mental and social stabilities factors showed significant differences in health recognition(p<0.001), interest in health(p<0.001) and alcohol drinking status(p<0.001). Among the factors influencing on the quality of life in dental health, interest in health(p<0.005), alcohol drinking(p<0.005) and physiological reaction in the midst of fear of dentist care(p<0.001) were the significant impact factor. Conclusions: It is necessary to develop a continuous and systematical program of dental health and dental care by experts so that the students can reduce the fear of dentist care by regular dental checkup and preventive treatment and care.

Piezoelectric Properties of (K,Na)$NbO_3$ ceramics with the amount of KCN addition (KCN 첨가에 따른 (K,Na)$NbO_3$ 세라믹스의 압전특성)

  • Seo, Byeong-Ho;Sung, Kum-Hyun;Lee, Sang-Ho;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.188-189
    • /
    • 2009
  • In this study, in order to develop excellent lead-free composition ceramics for piezoelectric transformer, $(K_4CuNb_8O_{23})$ added $(K_{0.5}Na_{0.5})(Nb_{0.96}Sb_{0.04})O_3$ ceramics were fabricated using conventional mixed oxide method and their piezoelectric and dielectric properties were investigated as a function of the amount of KCN addition. With increasing the amount of KCN addition, density and mechanical quality factor(Qm), electromechanical coupling factor (Kp) were increased up to 1.2mol% and then decreased. At the 1.2mol% KCN added specimen, mechanical quality factor (Qm), electromechanical coupling factor (Kp), density and dielectric constant (${\varepsilon}r$) showed the optimal values of 781, 0.445, $4.42g/cm^3$ and 443, respectively, for piezoelectric transformer application.

  • PDF

Piezoelectric and dielectric Properties for Multilayer Piezoelectric Transformer Of Modified $PbTiO_3$ system ceramics (적층 압전 변압기용 변성 $PbTiO_3$ 세라믹스의 압전 및 유전 특성)

  • Yoo, Kyung-Jin;Yoo, Ju-Hyun;Jeong, Yeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.344-345
    • /
    • 2006
  • In this study, in order to develop low temperature sintering piezoelectric transformer, $(Pb_{0.99-x}Ca_xSr_{0.01})Ti_{0.96}(Mn_{1/3}Sb_{2/3})_{0.04}O_3$ ceramic systems were fabricated using $Na_2CO_3-Li_2CO_3$ as sintering aids and investigated with the amount of Ca substitution. The piezoelectric transformer requires high electromechanical coupling factor $k_t$ and high mechanical quality factor $Q_{mt}$ for generating high output power At the ($PbCaSr)Ti(MnSb)O_3$ ceramics with 24mol% Ca substitution sintered at $900^{\circ}C$, electromechanical coupling factor $k_t$ and mechanical quality factor $Q_{mt}$ showed the optimal values of 0.504 and 1655 respectively, for thickness vibration mode multilayer piezoelectric transformer application.

  • PDF

Microwave dielectric properties of the BSST ceramics with BaO compositional ratio (BSST계 세라믹스의 BaO 조성비에 따른 마이크로파 유전특성)

  • 박인길;정장호;이성갑;이영희
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.81-85
    • /
    • 1996
  • Microwave dielectric properties of 0.15(B $a_{x}$S $r_{0.05}$)O-0.15(S $m_{2}$(1-y)N $d_{2y}$) $O_{3}$-0.7Ti $o_{2}$(x=o.9~0.1[mol.], y=6[m/o]) ceramics were investigated with BaO compositional ratio. Sintered density and resistivity of specimens were independent on the BaO compositional ratio. In the specimen with x=0.975[mol.], dielectric constant, quality factor and temperature coefficient of resonant frequency had good values of 76.52, 3001(at 3[GHz]) and +0.71[ppm/.ceg. C], respectively. By comparing with the stoichiometric compositions of 78.14, 2938(at 3[GHz])+14.19[ppm/.ceg. C], dielectric constant and quality factor showed similar properties, but the temperature coefficient of resonant frequency was highly improved. (author). refs., figs., tabs.s.s.

  • PDF

Frequency Dependance of Inductance of FeCoB Amorphous Magnetic Films (FeCoB계 아몰퍼스 자성박막의 인덕턴스의 주파수 의존성)

  • 신용진;소대화;김현욱;서강수;임재근
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.5
    • /
    • pp.413-417
    • /
    • 1998
  • In this paper, we investigate frequency dependance of inductance of FeCoB amorphous magnetic films. $(Fe_{1-x}Co_x)_{79}Si_2B_{19}$ was used as the basic composition of amorphous magnetic film having near zero magnetostriction. The amorphous magnetic films were fabricated with x=0.94 and x=0.95 by using sputtering method at high frequency. The films were anneald under non-magnetic field and near crystallization temperatures(30min at $280^{\circ}C$, 30min and 1hr at $400^{\circ}C$, respectively). As the results of the experiments with the fabricated films, the lowest coercive force was 0.084[Oe] at 400[W] of the input power and the crystallization temperature was $360^{\circ}C$ . In the case 30min at 40$0^{\circ}C$ the inductance value in the low frequency with x=0.95 was higher by 488% than that with x=0.94. The quality factor Q was below 0.7 for all samples. We obtained the highest quality value at 400[KHz] with 30min at $280^{\circ}C$ and x=0.94. The value was about 0.62. Also, the quality factor value was about 0.35 at 1[MHz] with 30min at $280^{\circ}C$ and x=0.95.

  • PDF