• Title/Summary/Keyword: Qualitative inspection

Search Result 88, Processing Time 0.028 seconds

Introduction to the Rationalized Environmental Monitoring Systems (환경영향평가 협의내용의 사후관리 합리화방안 연구)

  • Han, Sang-Wook;Choi, Jae-Yong;Lee, Chun-Won;Kim, Im-Soon;Jeon, Sook-Jin;Han, Jung-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.2
    • /
    • pp.119-126
    • /
    • 2000
  • Environmental monitoring system has been adopted and supplemented as inspection measures for the quantitative and qualitative changes of environmental impact assessment (EIA). Meanwhile it has been continuously pointed out that there is insufficient connection between environmental monitoring system and EIA. Often the agreed environmental impact assessment has not been fulfilled due to the argument of the cost, timing and situations of construction sites. Thus the purpose of this study is in search of the rationalized environmental monitoring system in order to harmonize the development and environmental conservation through the improvement of unreasonable aspects of the current EIA execution process. As to comply with the purpose, this research was carried out with three different but complimentary sources: environmental laws and regulations, foreign case studies of Japan, U.S.A. and Canada, and interviews with 73 experts. Finally, improved environmental monitoring system has been introduced reflecting the present process of EIA.

  • PDF

Edge Detection using Morphological Amoebas Noisy Images (잡음영상에서 아메바를 이용한 형태학적 에지검출)

  • Lee, Won-Yeol;Kim, Se-Yun;Kim, Young-Woo;Lim, Jae-Young;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.569-584
    • /
    • 2009
  • Edge detection in images has been widely used in image processing system and computer vision. Morphological edge detection has used structuring elements with fixed shapes. This paper presents morphological operators with non-fixed shape kernels, or amoebas, which take into account the image contour variations to adapt their shape. Experimental results are analyzed in both qualitative analysis through visual inspection and quantitative analysis with PFOM and ROC curves. The Experiments demonstrate that these novel operators outperform classical morphological operations with a fixed, space-invariant structuring elements for edge detection applications.

A Reliability Model of Process Systems with Multiple Dependent Failure States (다중 종속 고장상태를 갖는 공정시스템의 신뢰성 모델)

  • Choi, Soo Hyoung
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.37-41
    • /
    • 2018
  • Process safety technology has developed from qualitative methods such as HAZOP (hazard and operability study) to semi-quantitative methods such as LOPA (layer of protection analysis), and quantitative methods are actively studied these days. Quantitative risk assessment (QRA) is often based on fault tree analysis (FTA). FTA is efficient, but difficult to apply when failure events are not independent of each other. This problem can be avoided using a Markov process (MP). MP requires definition of all possible states, and thus, generally, is more complicated than FTA. A method is proposed in this work that uses an MP model and a Weibull distribution model in order to construct a reliability model for multiple dependent failures. As a case study, a pressure safety valve (PSV) is considered, for which there are three kinds of failure, i.e. open failure, close failure, and gas tight failure. According to recently reported inspection results, open failure and close failure are dependent on each other. A reliability model for a PSV group is proposed in this work that is to reproduce these results. It is expected that the application of the proposed method can be expanded to QRA of various systems that have partially dependent multiple failure states.

The Historical Paradigm of Corporate Social Responsibility (CSR) in Korea

  • Hyein WOO
    • Journal of Koreanology Reviews
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • This study will provide an overview of the development of 'Corporate Social Responsibility' (CSR) in South Korea throughout time, as well as its sources of inspiration and recommendations. The study will also rely on the body of existing research to provide insights into the present condition of CSR in the nation and the measures launched to promote socially responsible practices in the corporate environment. As a result, it will act as a crucial dedication to comprehending corporate social responsibility within the Korean environment. According to the searching results in the literature content dataset, there has been total four historical paradigm of CSR in South Korea, such as (1) Adoption of the CSR principles, (2) Introduction of the Korean Association of Social Responsibility, (3) The Seoul Environmental Charter, (4) The Board of Audit and Inspection Intervention. Based on the results of the current study, the present author could conclude that ingrained corporate social responsibility (CSR) is in Korean business culture, which has been promoted since the 1920s. Businesses can benefit by using the guidelines offered by the CSR Promotion Act and related activities to uphold their responsibilities towards society and the environment, overviewing comprehensively CSR advancement in South Korea from the 1920s to the display day.

Contemporary Safety Management of Virtual Golf in South Korea

  • MOON, Bo Ra;LEE, Seung Min;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.6 no.1
    • /
    • pp.1-4
    • /
    • 2022
  • Purpose: The purpose of this study is to provide implications for virtual golf safety management in Korea through the literature review of current safety issues of virtual golf industry. Research design, data, and methodology: This study employed a qualitative approach to review prior studies and related documents presenting current safety perspectives of virtual sports facility management. First, the study reviewed the experiences of virtual golf players and safety criteria suggested from previous literatures. Second, two experts in sport facility management reviewed the manuscript including implications and provided their opinions including major implications and insights for virtual sport industry. Views of experts were added to the final manuscript. Results: This study found that installation standards and safety and hygiene standards by industry are enacted for the safety management of sports facilities, however, there is a need for standards to be adjusted because the contents are general, abstract, and lack detail, thus causing difficultly to secure effectiveness. Conclusions: For virtual golf courses, it is necessary to develop a safety inspection checklist that suits the characteristics of indoor virtual golf. In this line, safety criteria need to be developed with the consideration of characteristics of screen golf to establish an efficient safety management system and create a safe use environment.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

A Study on Improvement of Image Quality Decrease due to Tooth Restoration in Facial CT (안면부 CT 검사 시 치아 충전물에 의한 화질 저하 개선 방안에 관한 연구)

  • Kim, Hyeon ju;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.497-503
    • /
    • 2018
  • The purpose of this study was to investigate the degree of image degradation and the improvement of image quality caused by the density difference between the orthodontic filling material and the surrounding anatomical structure during the examination of the facial CT by quantitative and qualitative analysis. The teeth were scanned using 64-MDCT (Discovery 750 HD, GE HEALTH CARE, Milwaukee, USA). The teeth were scanned and compared according to tube voltage, silicone application, and MAR application. As a result, 10.36% CT value decreased at 140 kVp and 5.81% decrease at the application of silicon material. As a result of the qualitative evaluation, it was evaluated that 7 of the 10 observers and 3 of the acceptors were applied to the MAR algorithm. Therefore, it is possible to reduce the unnecessary burden on the radiation exposure dose as well as to reduce the loss of image data by reducing the high density artifacts, as well as the inspection parameters used in the current clinical application and various algorithms that can reduce the high density artifacts. It can be expected to provide a lot of image information.

The Study on the Appropriate Workforce Estimation of Clinical Technologists for Job Creation in the Field of Ultrasonic Inspection

  • Bae, Hyung-Joon;Kim, Dae-Sik;Lee, Og kyoung;Kim, Chul-Seung;Choi, Sun Young;An, Young-Hoi;Kim, Eun-Young;Kang, Kun-Woo;Jang, Jin-Yong
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.381-389
    • /
    • 2019
  • The physiological function test is the only patient contact area in the field of clinical laboratory. We need to recruit and encourage the experts due to requiring the expertise and long time for examination. However, there is currently no rule for estimating optimal workforce in the field of physiological function tests. The purpose of this study is to establish the basis of the studies for mid- to long-long term job creation in the field of ultrasound by evaluating the number of appropriate tests and appropriate workforce. We calculated the quantitative and qualitative workload for the number of appropriate tests and appropriate workforce using online questionnaire. All statistical analyses were performed using SPSS version 18.0 (SPSS Inc., Chicago, IL, USA). A total of 216 respondents were 48 (22.2%) male and 168 (77.8%) female. A total of 157 laboratories were 62 (39.5%) for echocardiography, 91 (58.0%) for the transcranial Doppler (TCD) and 4 (5.7%) for the carotid ultrasound. The mean number of appropriate tests was 10 ± 2 in the echocardiography, 9 ± 2 in TCD and 11 ± 2 in the carotid ultrasound. In addition, the number of laboratories required to recruit employees for appropriate workforce was 19 in echocardiography, 18 in TCD, and 0 in carotid ultrasound. The number of hospital required to recruit workforce were 7 primary hospitals, 22 secondary hospitals, 7 third hospitals. This study can be used as an important data as the first study at present time when the data on the workforce status and work environment of the ultrasonic laboratories is insufficient. Based on the quantitative and qualitative workloads, the number of appropriate tests and appropriate workforce can support mid- to long-long term job creation in the field of ultrasound.

A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection (머리부 전후방향촬영 시 방사선피폭선량 저감을 위한 부가여과판에 대한 연구)

  • Lee, Cho-Hee;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3117-3122
    • /
    • 2011
  • Skull A-P projections are the bi-product where the ESD (Entrance Surface Dose) for digital radiography is much higher than that conventional screen-film radiography. Therefore, the aim of this study was to reduce radiation doses to patients by using an added filter. This research focuses on the identification of the reduction of exposure to radiation based on the thickness of an added filter when applying the 'Skull A-P Projection' by using the 'Skull Phantom'. Also, an experiment was conducted to evaluate the qualitative decline of images through filtration. The measurement of one's exposed dose to radiation was executed by locating the 'Skull Phantom' on the position of the 'Skull AP,' while changing 16 kinds of added filters from 0.1 mmAl to 0.5 mmCu + 2.0 mmAl in terms of incident and penetrating doses. For the qualitative evaluation of images, a total number of 17 images have been acquired in the 'Skull Phantom' under the same conditions as those for the measurement of one's exposed dose. The acquired images have been evaluated by a radiological specialist. As a result, the images with a diagnostic value have been obtained by using such added filters as the compound filter of 0.2 mmCu +1.0 mmAl. The exposed dose absorbed on the 'Skull Phantom' is about 0.6 mGy. The value is only 12% of 5 mGy, the ESD value acquired on the 'Skull P-A Projection', which is recommended by the International Atomic Energy Agency (IAEA). As a result, depending on the parts of inspection, it is possible to reduce the patient's exposed dosage of radiation considerably by using an appropriate added filter.