• Title/Summary/Keyword: Qualify assurance program

Search Result 5, Processing Time 0.03 seconds

Recent Progress of the DUPIC Fuel Fabrication in Korea

  • Lee, J.W.;Kim, W.K.;Lee, Jae-W.;Park, G.I.;YANG, M.S.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.170-181
    • /
    • 2004
  • DUPIC powder and pellets were successfully fabricated in accordance with the quality assurance program described in the Quality Assurance Manual for DUPIC fuel fabrication, which was developed on the basis of the CAN3-Z299.2-85 standard. This manual describes the quality management system applicable to the activities performed for DUPIC fuel fabrication. It covers the work processes, policies and procedures used for planning, executing, and verifying the work carried out for DUPIC fuel fabrication. It is important that a Quality Program is in place before the fabrication of the fuel for irradiation testing. In order to qualify the DUPIC pellet manufacturing processes, 3 series of experiments for the pre-qualification and 3 series for the qualification were performed. In these experiments, the optimum process conditions were established. Then, under the control of the QA program, 8 series of production runs were performed to make the qualified DUPIC pellets in a batch size of 1 kg. In these production runs, DUPIC fuel pellets satisfying the standard CANDU fuel pellet specifications could be successfully produced.

  • PDF

A Study on the Quality Assurance of Zipper Manufacturing Firms in Korea (한국 지퍼 제조업체의 품질보증 연구)

  • 장대성;이강언;신충섭
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.3
    • /
    • pp.152-161
    • /
    • 2001
  • Zipper manufacturing belongs to the small and medium industry. And it requires very accurate process and perfect quality control. In addition it is necessary to assure customers zipper qualify to explore new market. TQC as well as integration of existing quality control techniques for accurate and perfect processing should be implemented to assure product quality. To implement TQC zipper firms should invest in education programs for employees. Y zipper firm has succeeded in implementing the education program for TQC and Quality Circle and achieved the perfect quality control and quality assurance of products.

  • PDF

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

The Quality Assurance and Accuracy Improvement of National Basemap Digital Mapping Database (국가기본도 수치지도제작 데이터베이스의 품질유지 및 정확도 향상)

  • Lee, Hyun-Jik
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.2 s.12
    • /
    • pp.91-103
    • /
    • 1998
  • The digital map data of national basemap which will be basic data of the information age is accomplished to produce and are ready to distribute to public. Generally, the quality of digital map is affected to data history, position accuracy, attribute accuracy, logical consistency and completeness. The quality of digital map Is assured to use basic data for the field of various appication. The purpose of this study is to develop automated qualify control program of digital map through analysis type of errors in digital mapping, to determine method of high quality digital mapping. As a results of this study, The automated quality control program of digital map is developed to assure logical consistency and completeness of digital map which is used to principal data in the field of GIS and is determined the process of high quality digital mapping. Also, the results of this study is contributed to quality assrence and accuracy improvement of national basemap digital mapping database.

  • PDF

Comparison Study of Conventional Film-based and CT-reconstruction method in HDR Brachytherapy (고선량률 근접 방사선 치료에서 기존의 필름 방법과 CT 재구성 방법의 비교 연구)

  • 장지나;이형구;윤세철;서태석
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.63-69
    • /
    • 2004
  • HDR brachytherapy administers a large dose of radiation in a short time compare with LDR, and its optimization for treatment is related to several complex factors, such as physical, radiation and optimization algorithms, so there is a need for these to be verified for accurate dose delivery. In our approach, a previous study concerning the phantom for dose verification has been modified, and a new pelvic phantom fabricated for the purpose of localization, including a structure enabling the use of a CT or MRI system. In addition, a comparison study was performed to verify an orthogonal method that is commonly used for brachytherapy localization by comparing target coordinates from a CT system. Since the developed phantom was designed to simulate the clinical setups of cervix cancer, it included an air-filled bladder and a rectum structure shaped sphere and cylinder An N-shaped localizer was used to obtain precision coordinates from both CT and films. Moreover, the IDL 5.5 software program for Windows was used to perform coordinates analysis based on an orthogonal algorithm. The film results showed differences within 1.0 mm of the selected target points compare with the CT coordinates. For these results, a Plato planning system (Nucletron, Netherlands) could be independently verified using this phantom and software. Furthermore, the new phantom and software will be efficient and powerful qualify assurance (QA) tools in the field of brachytherapy QA.

  • PDF