• Title/Summary/Keyword: Quadrupole

Search Result 380, Processing Time 0.027 seconds

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

Analysis of Acoustic Characteristics of Muffler including Flow effects (유체유동을 포함한 소음기의 음향 특성 해석)

  • Kim, Hyung-Tae;Jeong, Weu-Bong;Kim, Heui-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.861-864
    • /
    • 2006
  • In general, 4-pole parameter and three-point method are used for predicting transmission loss which is one of characteristics of Muffler using CAE tools. However, these mehtods show different results from experiment when the flow effects are presented in practical model. In this parer, to overcome these problems, both Fluent and.Sysnoise are used to analyze the performance of extended inlet/outlet muffler including flow effects with varying flow velocity at inlet of duct. Flow fields and quadrupole source is calculated by Fluent. And Sysnoise is used to analyze acoustic performances of muffler with quadrupole source data extracted from Fluent. Finally, the variation of transmission loss is estimated according to various inlet flow velocity.

  • PDF

Deuterium NMR Studies of $({\mu}_3-C^2H)[Co(CO)_3]_3$

  • Woo, Ae-Ja;Maria I. Altbach;Leslie G. Butler
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.2
    • /
    • pp.95-102
    • /
    • 1997
  • Deuterium quadrupole coupling constant (e2qzzQ/h) of ($\mu$3-C2H)[Co(CO)3]3 was determined by using solid-state deuterium MAS NMR spectroscopy. The small quadrupole coupling constant of bridging methyne unit relative to sp-acethylene in propyne is discussed in terms of the C-H bond length and the negative charge on the carbon.

  • PDF

Chemical Shift and Quadrupolar Interactions in Solids

  • Kim Jin-Eun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.1-37
    • /
    • 2006
  • General expressions for solid state NMR lines are described for transitions under static, magic angle spinning, and variable angle spinning conditions in the case where the principal axis system for the anisotropic chemical shift tensor is noncoincident with that of the quadrupole coupling tensor. It is demonstrated that solid state NMR powder pattern simulation program VMAS based on the conventional grid point method of integrating over the Euler angle space is fast enough in comparison with the POWDER simulation package and Gauss-point method.

  • PDF

ZORA DFT Calculation of $^{11}$B Electric Field Gradient Tensor for Lithium Borates

  • Woo, Ae-Ja;Wasylishen, Roderick E.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.8 no.2
    • /
    • pp.70-76
    • /
    • 2004
  • ZORA-DFT calculations of $^{11}$B EFG (electric field gradient) tensors for lithium borates, LiB$_3O_5$ (LBO) and Li$_2B_4O_7$ (LTB), were performed. The calculated values of 11B quadrupole coupling constant and asymmetry parameter are in good agreement with the experimental values. The sign of the quadrupole coupling constant for the tetrahedral boron site was deduced from the distortion from the ideal tetrahedral symmetry.

  • PDF

Electric Quadrupole Interaction in Copper-Iron-Chromium Oxide (구리-철-크롬 산화물에서의 전기사중극자 상호작용)

  • Shu, Seung-Wook;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.3
    • /
    • pp.89-93
    • /
    • 2008
  • Ferrimagnetic Copper-Iron-Chromium Oxide $CuFe_{0.9}Cr_{1.1}O_4$ has been investigated over a temperature range from liquid nitrogen temperature upto $N{\acute{e}}el$ temperature using the Mossbauer technique. Its $N{\acute{e}}el$ temperature is found to be 355 K. Above the $N{\acute{e}}el$ temperature the quadrupole splitting is found to be 0.50 mm/s. On the other hand, all the electric quadrupole shift values are zero below the $N{\acute{e}}el$ temperature within experimental error. These seemingly contradictory phenomena have been explained by the model that the magnetic hyperfine field is randomly oriented with respect to the principal axes of the electric-field-gradient tensor.

Determination of ginsenosides in Asian and American ginsengs by liquid chromatography-quadrupole/time-of-flight MS: assessing variations based on morphological characteristics

  • Chen, Yujie;Zhao, Zhongzhen;Chen, Hubiao;Brand, Eric;Yi, Tao;Qin, Minjian;Liang, Zhitao
    • Journal of Ginseng Research
    • /
    • v.41 no.1
    • /
    • pp.10-22
    • /
    • 2017
  • Background: Asian ginseng and American ginseng are functional foods that share a close genetic relationship and are well-known worldwide. This article aims to investigate the correlation between morphological characteristics and the inherent quality of Asian and American ginsengs. Methods: In this study, an ultra-HPLC-quadrupole/time-of-flight MS (UHPLC-Q/TOF-MS) method was established for the quantitative analysis of 45 ginseng samples. The method developed for determination was precise and accurate. Results: The results showed that Asian ginseng samples with the same growing time (with the same or similar number of stem scars) that had a thinner main root, a longer rhizome and more branch roots contained greater amounts of ginsenosides. For American ginseng, two tendencies were observed in the relationship between the diameter of the main root and contents of ginsenosides. One tendency was that samples with thinner main roots tended to contain higher levels of ginsenosides, which was observed in the samples sold under the commercial name pao-shen. Another tendency was that samples with thicker main roots contained higher contents of ginsenosides, which was observed in the samples sold under the commercial name pao-mian, as well as in samples of American ginseng cultivated in Jilin, China. Conclusion: An approach using ultra-HPLC-quadrupole/time-of-flight MS was successfully established to link morphology and active components for evaluating the quality of Asian and American ginsengs. Clear correlation between visible morphological features and quality of Asian and American ginsengs was found. People can see the difference; this means consumers and vendors can evaluate ginseng by themselves.

Tentative identification of 20(S)-protopanaxadiol metabolites in human plasma and urine using ultra-performance liquid chromatography coupled with triple quadrupole time-of-flight mass spectrometry

  • Ling, Jin;Yu, Yingjia;Long, Jiakun;Li, Yan;Jiang, Jiebing;Wang, Liping;Xu, Changjiang;Duan, Gengli
    • Journal of Ginseng Research
    • /
    • v.43 no.4
    • /
    • pp.539-549
    • /
    • 2019
  • Background: 20(S)-Protopanaxadiol (PPD), the aglycone part of 20(S)-protopanaxadiol ginsenosides, possesses antidepressant activity among many other pharmacological activities. It is currently undergoing clinical trial in China as an antidepressant. Methods: In this study, an ultra-performance liquid chromatography coupled with triple quadrupole time-of-flight mass tandem mass spectrometry method was established to identify the metabolites of PPD in human plasma and urine following oral administration in phase IIa clinical trial. Results: A total of 40 metabolites in human plasma and urine were identified using this method. Four metabolites identified were isolated from rat feces, and two of them were analyzed by NMR to elucidate the exact structures. The structures of isolated compounds were confirmed as (20S,24S)-epoxydammarane-12,23,25-triol-3-one and (20S,24S)-epoxydammarane-3,12,23,25-tetrol. Both compounds were found as metabolites in human for the first time. Upon comparing our findings with the findings of the in vitro study of PPD metabolism in human liver microsomes and human hepatocytes, metabolites with m/z 475.3783 and phase II metabolites were not found in our study whereas metabolites with m/z 505.3530, 523.3641, and 525.3788 were exclusively detected in our experiments. Conclusion: The metabolites identified using ultra-performance liquid chromatography coupled with triple quadrupole time-of-flight mass spectrometry in our study were mostly hydroxylated metabolites. This indicated that PPD was metabolized in human body mainly through phase I hepatic metabolism. The main metabolites are in 20,24-oxide form with multiple hydroxylation sites. Finally, the metabolic pathways of PPD in vivo (human) were proposed based on structural analysis.

Development of High Current Shunt Regulator for Beam Based Alignment in PLS 2GeV Storage Ring (포항방사광가속기 빔위치 정렬 용 정밀전원장치 개발)

  • Nam, S.H.;Suh, J.H.;Ha, K.M.;Huang, J.Y.;Ko, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2249-2251
    • /
    • 1997
  • Total 144 quadrupole magnets are installed in PLS. The magnets are connected in series with groups of two or 24. Each group is powered by a high-precision constant-current DC power supply. For the purpose of the beam based alignment of beam position monitors in the PLS, it is necessary to adjust the current of each quadrupole independently. To achieve this, a high current shunt regulator is designed. It can shunt a maximum 50 A of the quadrupole magnet current. The shunt regulator is programmable and the current amplitude can be varied linearly with a 12-bit resolution. Power transistors are used in the current shunt regulator. The operation of transistors is in linear region. The RS232C protocol is used for remote control and status report of the shunt regulator to the main control centre of the PLS. Preliminary result indicates that the calibration accuracy of the beam position monitor can be achievable in less than $10{\mu}m$.

  • PDF