• 제목/요약/키워드: QRS-complex

검색결과 132건 처리시간 0.026초

Cardioprotective effect of Argyreia speciosa (Burm. f) Boj. extracts against Isoproterenol- induced myocardial infarction in rats

  • Thakker, Shalin;Biradar, S.M.;Habbu, P.V.;Mahadevan, K.M.;Thippeswamy, B.S.;Veerapur, V.P.
    • Advances in Traditional Medicine
    • /
    • 제10권4호
    • /
    • pp.278-287
    • /
    • 2010
  • The present study was undertaken to evaluate the protective effect of ethanol (EtAS), ethyl acetate (EAAS) and aqueous (AQAS) extracts of Argyreia speciosa (AS) roots against Isoproterenol (ISO)-induced myocardial infarction in rats. The animals were exposed to isoproterenol (200 mg/kg. s.c) twice at an interval of 24 hrs. Cardioprotective effect was assessed by observing ECG parameters, serum marker enzymes and histopathology of the heart. Pretreatment of EAAS, and EtAS (200 mg/kg) resulted in a significant (P < 0.001) increase in P wave, QRS complex and R-R interval, whereas heart rate, QT interval and cardiac cycle were maintained near to normal values. EtAS and EAAS showed significant (P < 0.05; P < 0.001) reduction in all the tested diagnostic markers compared to ISO treated group. Histological studies on the structural changes of heart tissue supported the protective activity of AS. The result suggest that treatment of AS prior to ISO has a significant role in protecting the animals from ISO induced myocardial infarction.

A Method of Analyzing ECG to Diagnose Heart Abnormality utilizing SVM and DWT

  • Shdefat, Ahmed;Joo, Moonil;Kim, Heecheol
    • Journal of Multimedia Information System
    • /
    • 제3권2호
    • /
    • pp.35-42
    • /
    • 2016
  • Electrocardiogram (ECG) signal gives a clear indication whether the heart is at a healthy status or not as the early notification of a cardiac problem in the heart could save the patient's life. Several methods were launched to clarify how to diagnose the abnormality over the ECG signal waves. However, some of them face the problem of lack of accuracy at diagnosis phase of their work. In this research, we present an accurate and successive method for the diagnosis of abnormality through Discrete Wavelet Transform (DWT), QRS complex detection and Support Vector Machines (SVM) classification with overall accuracy rate 95.26%. DWT Refers to sampling any kind of discrete wavelet transform, while SVM is known as a model with related learning algorithm, which is based on supervised learning that perform regression analysis and classification over the data sample. We have tested the ECG signals for 10 patients from different file formats collected from PhysioNet database to observe accuracy level for each patient who needs ECG data to be processed. The results will be presented, in terms of accuracy that ranged from 92.1% to 97.6% and diagnosis status that is classified as either normal or abnormal factors.

심전도 자동 진단 알고리즘 및 장치 구현(I) - YECGA 개요 (An implementation of automated ECG interpretation algorithm and system(I) - Introduction of YECGA)

  • 권혁제;정기삼;정성진;최석준;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.175-178
    • /
    • 1996
  • The purpose of this thesis is the propose of various signal processing algorithm for the ECG(electrocardiogram) and the design of realtime automated ECG analyzer feasible with these algorithms. The algorithms are composed of (1)filtering procedure fer the estimation and removal of baseline drift, 60Hz power line interference, and muscle artifacts (2)detection procedure of QRS complex and P wave (3)typification procedure for the pattern classification according to the morphologies (4) selection of representative beat, significant point and wave boundary decision procedure and (5) parameter extraction and diagnosis procedure. All verifications are carried out between the algorithms proposed in this paper and other algorithms already proposed by many researchers, for the objective comparison in each procedure. The efficiency of proposed algorithms are demonstrated with the aid of internationally validated CSE database and the performances of filtering procedure are compared on artificial noise signal as well as actual ECG signals with appropriate noise components. for the comparison on the performance of designed automated ECG analyzer, the diagnosis results were compared with ECG analyzer manufactered by Fukuda denshi in Japan.

  • PDF

HRV의 전력스펙트럼 분석에 관한 연구 (A Study on the Power Spectral Analysis of Heart Rate Variability)

  • 정성진;정기삼;신건수;이병채;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.217-220
    • /
    • 1996
  • In this paper, we compare three mehods to obtain PSD of HRV - FFT, AR modeling, and residual integration. Using these methods we speculate the balances of the LP and HF powers of HRV at $0^{\circ}$, $45^{\circ}$, $90^{\circ}$ tilt levels of head-up tilt table for young and healthy 24 men. R peaks are located at the highest point of QRS complex detected from modified spacial velocity algorithm. In general FFT is the most fast way to obtain PSD but PSD from FFT has too many peaks and valleies. AR PSD can show frequency of ANS activity effectively but LF component of PSD is often invisible due to interference of VLF power. The residual integration method that decomposes the AR PSD is very efficient way to extract LF component. Applying the above three methods to HRV we can visualize the trend of PSD variations along tilt levels.

  • PDF

심전도 측정을 이용한 모바일 헬스케어 시스템 개발 (Development of Mobile Healthcare System Using ECG Measurement)

  • 김성우;신승철
    • 한국정보통신학회논문지
    • /
    • 제18권8호
    • /
    • pp.2008-2016
    • /
    • 2014
  • 최근 건강관리 및 심장질환 관리 등에 대한 관심이 증가하면서 유비쿼터스 헬스케어 서비스와 관련 기기에 대한 개발이 활발히 이루어지고 있다. 본 논문에서는 패치형 심전도 측정기기와 연동된 스마트폰으로 구성된 모바일 헬스케어 시스템을 개발하였다. 본 시스템은 실시간으로 심전도, 맥박, 스트레스 지수를 모니터링하고 저장 및 전송하는 기능과 심박 수에 따른 건강관리 기능 등을 제공한다. 이처럼 웨어러블 생체신호 측정 장치와 연동된 모바일 헬스케어 시스템을 통해 생체 신호를 지속적으로 모니터링함으로써 사용자는 만성질환을 예방하고 꾸준히 건강을 유지할 수 있다. 본 논문에서는 실제 플랫폼에 탑재되어 구현된 결과를 보여준다.

단일 채널 두피 뇌전도에서의 심전도 잡음 추정 및 제거 (Estimation and Elimination of ECG Artifacts from Single Channel Scalp EEG)

  • 조성필;송미혜;박호동;이경중;박영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1910-1911
    • /
    • 2007
  • A new method for estimating and eliminating electrocardiogram (ECG) artifacts from single channel scalp electroencephalogram (EEG) is proposed. The proposed method consists of emphasis of QRS complex from EEG using least squares acceleration (LSA) filter, generation of synchronized pulse with R-peak and ECG artifacts estimation and elimination using adaptive filter. The performance of the proposed method was evaluated using simulated and real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, which are independent component analysis (ICA) and ensemble average (EA) method. In conclusion, we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifacts from single channel EEG and simple to use for ambulatory/portable EEG monitoring system.

  • PDF

웨어러블 디바이스를 위한 실시간 부정맥 검출 및 BLE기반 데이터 통신 알고리즘 개발과 적용 (Development of Real-Time Arrhythmia Detection and BLE-based Data Communication Algorithm for Wearable Devices)

  • 맹수훈;김대관;이현석;문효정
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.399-408
    • /
    • 2022
  • Because arrhythmia occurs irregularly, it should be examined for at least 24 hours for accurate diagnosis. For this reason, this paper developed firmware software for arrhythmia detection and prevented consumption of temporal and human resources and enabled continuous management and early diagnosis. Prior to the experiment, the interval between the R peaks of the QRS Complex was calculated using the Pan-Tompkins algorithm. The developed firmware software designed and implemented an algorithm to detect arrhythmia such as tachycardia, bradycardia, ventricular tachycardia, persistent tachycardia, and non-persistent tachycardia, and a data transmission format to monitor the collected data based on BLE. As a result of the experiment, arrhythmia was found in real time according to the change in BPM as designed in this paper. And the data quality for BLE communication was verified by comparing the sensor's serial communication value with the Android application reception value. In the future, wearable devices for real-time arrhythmia detection will be lightweight and developed firmware software will be applied.

Ginseng total saponin attenuates myocardial injury via anti-oxidative and anti-inflammatory properties

  • Aravinthan, Adithan;Kim, Jong Han;Antonisamy, Paulrayer;Kang, Chang-Won;Choi, Jonghee;Kim, Nam Soo;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • 제39권3호
    • /
    • pp.206-212
    • /
    • 2015
  • Background: Ginseng total saponin (GTS) contains various ginsenosides. These ginsenosides are widely used for treating cardiovascular diseases in Asian communities. The aim of this study was to study the effects of GTS on cardiac injury after global ischemia and reperfusion (I/R) in isolated guinea pig hearts. Methods: Animals were subjected to normothermic ischemia for 60 minutes, followed by 120 minutes of reperfusion. GTS significantly increased aortic flow, coronary flow, and cardiac output. Moreover, GTS significantly increased left ventricular systolic pressure and the maximal rate of contraction ($+dP/dt_{max}$) and relaxation ($-dP/dt_{max}$). In addition, GTS has been shown to ameliorate electrocardiographic changes such as the QRS complex, QT interval, and RR interval. Results: GTS significantly suppressed the biochemical parameters (i.e., lactate dehydrogenase, creatine kinase-MB fraction, and cardiac troponin I levels) and normalized the oxidative stress markers (i.e., malondialdehyde, glutathione, and nitrite). In addition, GTS also markedly inhibits the expression of interleukin-$1{\beta}$ (IL-$1{\beta}$), IL-6, and nuclear factor-${\kappa}B$, and improves the expression of IL-10 in cardiac tissue. Conclusion: These data indicate that GTS mitigates myocardial damage by modulating the biochemical and oxidative stress related to cardiac I/R injury.

광전용적맥파 센서를 이용한 맥파전달시간의 측정 (Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor)

  • 최병철;정동근;정도운;노정훈;전계록
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

남녀 및 나이에 따른 심자도 변수 차이 분석 (Analysis of the Parameters of Magnetocardiography Depending on the Age and Gender)

  • 임현균;정남식;이용호;권혁찬;정보영;박용기
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.530-538
    • /
    • 2007
  • Magnetocardiography (MCG) is a device to measure the magnetic field from the heart. It is a noninvasive device and takes only few minutes to record magnetocardiogram from a subject. In this study, we compared the difference of MCG data recorded from 56 normal subjects in early twenties (28 males and 28 females, mean $age=21.0{\pm}1.6$ years) and 36 elderly subjects (20 males and 16 females, mean $age=61.9{\pm}6.9$ years) for the analysis of the age and gender difference. A total of 24 parameters used in the analysis were derived from QRS complex, R-wave, T-wave, and ST-T period. As a result, seven parameters including maximum current angle and map angle showed the significant difference (p<0.01 and p<0.05, respectively) between young males and young females. Significant difference (p<0.05) between elderly males and elderly females was found from a parameter, pole distance at T-wave peak. In the comparison of age difference, seven parameters regarding current moment, pole distance, and dynamics showed the significant difference between young and elderly males. Eight parameters also showed significant difference (p<0.05) between two younger and elderly female groups. Results showed that parameters regarding current moment, pole distance, and dynamics might be changed when people get older. In conclusion, gender and age difference should be considered when MCG data are analyzed for certain parameters.