• Title/Summary/Keyword: QPM

Search Result 35, Processing Time 0.024 seconds

High Resolution Rainfall Prediction Using Distributed Computing Technology (분산 컴퓨팅 기술을 이용한 고해상도 강수량 예측)

  • Yoon, JunWeon;Song, Ui-Sung
    • Journal of Digital Contents Society
    • /
    • v.17 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Distributed Computing attempts to harness a massive computing power using a great numbers of idle PCs resource distributed linked to the internet and processes a variety of applications parallel way such as bio, climate, cryptology, and astronomy. In this paper, we develop internet-distributed computing environment, so that we can analyze High Resolution Rainfall Prediction application in meteorological field. For analyze the rainfall forecast in Korea peninsula, we used QPM(Quantitative Precipitation Model) that is a mesoscale forecasting model. It needs to a lot of time to construct model which consisted of 27KM grid spacing, also the efficiency is degraded. On the other hand, based on this model it is easy to understand the distribution of rainfall calculated in accordance with the detailed topography of the area represented by a small terrain model reflecting the effects 3km radius of detail and terrain can improve the computational efficiency. The model is broken down into detailed area greater the required parallelism and increases the number of compute nodes that efficiency is increased linearly.. This model is distributed divided in two sub-grid distributed units of work to be done in the domain of $20{\times}20$ is networked computing resources.

Fluoride single crystals for UV/VUV nonlinear optical applications

  • Shimamura Kiyoshi;Villora Encarnacion G.;Muramatsu Kenichi;Kitamura Kenji;Ichinose Noboru
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.4
    • /
    • pp.133-140
    • /
    • 2006
  • The growth characteristics and properties of large size $SrAlF_5$ single crystals are described and compared with those of $BaMgF_4$. Transmission spectra in the vacuum ultraviolet wavelength region indicate a high transparency of $SrAlF_5$ (about 90% without considering surface reflection loses) down to 150 nm, on contrast to the optical loses observed for $BaMgF_4$. The ferroelectric character of $SrAlF_5$ is evidenced by the reversal of the spontaneous polarization in a hysteresis loop. The higher potential of $SrAlF_5$ in comparison with $BaMgF_4$ for the realization of all-solid-state lasers in the ultraviolet wavelength region by the quasi-phase matching (QPM) technique is pointed out. $SrAlF_5$, besides a higher grade of transparency, shows a nonlinear effective coefficient similar to that of quartz and uniaxial nature, on contrast to the one order smaller nonlinear coefficient and biaxial character of $BaMgF_4$. The refractive index of $SrAlF_5$ from the ultraviolet to the near-infrared wavelength region is measured by the minimum deviation method. The Sellmeier and Cauchy coefficients are obtained from the fits to the curves of the ordinary and extraordinary refractive indices, and the grating period for the first order QPM is estimated as a function of the wavelength. The poling periodicity for 193 nm SHG from 386 nm is $4{\mu}m$.

Fabrication of periodically poled lithium niobate and quasi-phase matched second harmonic generation (주기적 분극반전된 LiN$bO_3$ 결정의 제작과 유사위상정합 2차조화파 발생)

  • 노정훈;김홍기;전옥엽;차명식;김봉기;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.306-307
    • /
    • 2000
  • 1962년 Armstrong 등에 의해 second harmonic generation(SHG) 의 이론이 완성된 후 SHG 효율을 높이기 위한 방법으로 비선형성이 큰 물질의 개발과 더불어 위상정합(phase matching)을 만족시키는 여러가지 방법이 연구 되었다. 특히 위상정합의 경우 지금까지는 복굴절을 이용하는 방법이 널리 사용되었으나 이 경우 입사광의 파장이 제한적이고, 많은 무기물 결정에서 비선형광학계수의 가장 큰 텐서 성분인 $d_{zzz}$를 사용할 수 없다는 단점을 가지고 있다. 반면 유사위상정합(Quasi-phase matching:QPM) 은 비선형광학계수( $d_{zzz}$)의 방향을 결맞음 길이(coherence length)마다 분극반전 시켜주어 2차 조화파의 진폭을 길이방향으로 계속 증가시키는 방법으로 구역반전된 길이를 조절하면 거의 모든 파장에 대해 비임계 위상정합( $d_{zzz}$ 사용)이 가능하고, 2차 조화파가 기본파의 전파경로에서 벗어나는 walk-off 현상이 없어 SHG 전환효율을 극대화할 수 있다. (중략). (중략)

  • PDF

Quasi-phase matched optical parametric oscillators using periodically poled $KNbO_3$ crystals (주기적으로 분극 반전된 $KNbO_3$를 이용한 준위상 정합 광 매개 진동자)

  • Lee Gwang Jo;Kim Jung Hyeon;Im Min Ho;O Hyeon Ho;Lee Don Hui;Yun Chun Seop
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.230-231
    • /
    • 2003
  • $KNbO_3$is one of the best materials for efficient nonlinear frequency conversion, due to its large nonlinear optical coefficient ($d_{33}$ = 20.6 pm/V), wide transparency range (0.4 ~ 5 $\mu$m) and freedom from photorefractive effects. Quasi-phase-matched second harmonic generation using periodically poled $KNbO_3$ (PPKN) crystals has been reported. Here we report on fabrication of PPKN and demonstration of a pulsed optical param etric oscillator (QPM OPO) pumped by an Nd:YAG laser. (omitted)

  • PDF

A study on the periodical domain obtained in Nd : $LiNbO_3$ sinlgle crystals grown by czochralski method (Czochralski법에 의해 성장시킨 Nd : $LiNbO_3$ 단결정의 주기적인 domain제어에 관한 연구)

  • 최종건
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.1
    • /
    • pp.50-55
    • /
    • 2002
  • $Nd_2O_3$0.2~0.5 wt.% doped $LiNbO_3$single crystals were grown by the Czochralski method. The ZnO doping by 2~8 mole% can improve the resistance of optical damage. In this study, Nd : LiNbO$_3$ single crystals with the periodical domain structure were obtained by CZ method.

Power Characteristics of cw Second-harmonic Generation in Periodically Poled LiNbO3

  • Kang, Bong-Hoon;Joo, Gi-Tae;Rhee, Bum-Ku
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.5
    • /
    • pp.430-432
    • /
    • 2010
  • We verified through a noncritical phase-matched second-harmonic generation experiment that the periodically-poled $LiNbO_3$ (PPLN) had a large effective nonlinear optical coefficient, demonstrating that the QPM grating was uniform throughout the entire length of PPLN. The quasi-phase matching temperature was $193.4^{\circ}C$. The maximum SHG output power at the fundamental power of 2.0 W was found to be 18.0 mW; generated second-harmonic beam was found to have no photorefractive effect.

Characteristics of output for optical parametric oscillation in periodically poled $LiNbO_3$ pumped by dioded-pumped Nd:YAG laser (다이오드 펌프 Nd:YAG 레이저로 펌프된 주기적 분극 반전된 $LiNbO_3$ OPO의 출력 특성)

  • 조기호;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.68-69
    • /
    • 2003
  • Quasi-Phase-Matching(QPM)을 이용한 Optical Parametric Oscillation(OPO)은 높은 효율과 작은 Walk-off 효과를 보인다는 장점을 가지고 있다. 그러나 작은 펌프빛의 크기로 인한 빛세기의 증가는 optical damage와 photorefractive effect 야기하고, 이러한 요인으로 안정적인 고출력 연속발진에 있어서는 그 한계가 있으리라고 생각되어진다. 본 연구에서는 주기가 27.7 $mu extrm{m}$인 Periodically poled LiNbO$_3$(PPLN)을 비선형매질로 이용하여 10 kHz의 고반복률을 갖는 다이오드 펌프 Nd:YAG 레이저에서의 Quasi-Phase-Matched Optical Parametric Oscillation의 Signal파의 출력특성 및 안정화에 대하여 조사를 하였다. (중략)

  • PDF

Poling Quality Enhancement of PPLN Devices Using Negative Multiple Pulse Poling Method

  • Choi, Ju-Won;Ro, Jung-Hoon;Ko, Do-Kyeong;Yu, Nan-Ei
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.182-186
    • /
    • 2011
  • A poling method using multiple negative voltage was introduced to fabricate periodically poled lithium niobate (PPLN) devices with quasi-phase matching (QPM) period of $12.9\;{\mu}m$ by utilizing an real-time visualization system. We also performed variation of the electric field during the poling. Two different conventionally used poling method, negative and positive single pulses, were used and the poling quality compared through microscopic images and far-field diffraction pattern analysis. Etched images on the +z and -z surfaces of PPLN showed that negative multiple pulse poling presented the highest periodicity in domain structures among the three methods. Duty ratio and its standard deviation were measured by analyzing far-field diffraction patterns. The newly introduced method of negative multiple pulse poling had duty ratio of 0.42 which was close to the ideal value of 0.50 and standard deviation of 0.020 that was about 3 times smaller than that of the other conventional methods.