• Title/Summary/Keyword: QGS

Search Result 20, Processing Time 0.024 seconds

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

Effects of Perfusion Defect on the Measurement of Left Ventricular Mass, Ventricular Volume and Post-stress Left Ventricular Ejection Fraction in Gated Myocardial Perfusion SPECT (정량적 게이트 심근관류 스펙트 검사에서 관류결손이 좌심근질량 측정과 부하 후 좌심실 용적 및 구혈률에 미치는 영향)

  • Ahn, Byeong-Cheol;Bae, Sun-Keun;Lee, Sang-Woo;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.381-391
    • /
    • 2002
  • Purpose: The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluate the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Subjects and Methods: Forty-six patients (male/female=34:12, mean age=64years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by AutoQUANT program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. Results: LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS un patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between EDVs, ESVs, EFs than patients with reversible defect. Conclusion: These results suggest that perfusion defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

Meat Tenderness Characteristics of Ten Major Muscles from Hanwoo Steers according to Quality Grades of Carcasses

  • Lee, Kyu-Won;Hwang, Young-Hwa;Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.37 no.4
    • /
    • pp.593-598
    • /
    • 2017
  • The objective of this study was to determine the influence of quality grade (QG) on meat tenderness characteristics of ten major muscles from Hanwoo steers. A total of 25 Hanwoo carcasses ($5\;carcasses{\times}5\;QGs$) were selected. Intramuscular fat content, collagen content, sarcomere length, and Warner-Bratzler shear force (WBSF) of Longissimus thoracis (LT), Longissimus lumborum (LL), Psoas major (PM), Semisponals (SS), Triceps brachii (TB), Semimembranosus (SM), Gluteus medius (GM), Rectus Abdominis (RA), Superficialis flexor (SF), and Internal and external intercostal (IC) were determined. IC had the highest fat content, followed by LT, RA, LL, PM, GM, SS, SF, TB, and SM. High-fat muscles such as LT, LL, IC, RA, and PM had significantly (p<0.05) different fat contents among QGs. Collagen contents were significantly (p<0.05) different among QGs. With decreasing QG, increasing collagen content was found in muscles. There were significant (p<0.05) differences in sarcomere length among QGs of several muscles. However, no significant (p>0.05) difference in sarcomere length was found among QGs for LL, PM, or RA muscle. PM had the lowest WBSF, followed by LL, LT, RA, IC, GM, SM, SF, SS, and TB. WBSF of QG $1^{{+}{+}}$ was lower than that of QG 1 for SS, TB, and SM. All muscles of QG 1 showed lower WBSF than QG 3 except TB or IC. Results of this study suggested that differences in WBSF among these 10 muscles by QG were due to differences in collagen content and sarcomere length.

Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program (게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교)

  • Jeong, Young-Jin;Park, Tae-Ho;Cha, Kwang-Soo;Kim, Moo-Hyun;Kim, Young-Dae;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.430-437
    • /
    • 2005
  • Purpose: The objectives of this study were - First, to determine the normal range of left ventricular end diastolic volume (EDV), end systolic volume (ESV) and election fraction (EF) from gated myocardial perfusion SPECT for Quantitative Gated SPECT (QGS) and 4D-MSPECT (4DM), respectively. Second, to evaluate the relationships between values produced by both software packages. Materials & Methods: Tc-99m MIBI gated myocardial perfusion SPECT were performed for 77 patients (mean age: $49.6{\pm}13.7y$, n=37(M), 40(F)) with a low likelihood (<10%) of coronary artery disease (CAD) using dual head gamma camera (E.CAM, Siemens, USA). Left ventricular EDV, ESV and EF were automatically measured by means of QGS and 4DM, respectively. Results: in QGS, the mean EDV, ESV and EF for all patients were $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml\;and\;66.6{\pm}8.0%$ at stress test respectively, not different from rest test (p>0.05). In 4DM, the mean EDV, ESV and EF for all patients were $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml\;and\;68.5{\pm}6.7%$ at stress test. Most cases in 4DM, there was no significant difference statistically between stress and rest test (p>0.05). But statistically significant difference was found in EF ($68.5{\pm}6.7%$ at stress vs $70.9{\pm}8.0%$ at rest, p<0.05). Correlation coefficients between the methods for EDV, ESV and EF were comparatively high (0.95, 0.93, 0.71 at stress test and 0.95, 0.90, 0.69 at rest test, respectively). However, Bland-Altman plots showed a large range of the limit value of agreement for EDV, ESV and EF between both methods ($-30ml{\sim}10ml,\;-12ml{\sim}8ml,\;-14%{\sim}11%$ at stress test and $-32ml{\sim}5ml,\;-13ml{\sim}13ml,\;-18%{\sim}12%$ at rest test). Conclusion: We found the normal ranges of EDV, ESV and EF for patients with a low likelihood of CAD in both methods. We expect these values will be a good reference to interpret gated myocardial perfusion SPECT. Although good correlation was observed between both methods, they should not be used interchangeably. Therefore, when both programs are used at the same site, it will be important to apply normal limits specific to each method.

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

Comparison of Carcass and Sensory Traits and Free Amino Acid Contents among Quality Grades in Loin and Rump of Korean Cattle Steer

  • Piao, Min Yu;Jo, Cheorun;Kim, Hyun Joo;Lee, Hyun Jung;Kim, Hyun Jin;Ko, Jong-Youl;Baik, Myunggi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.11
    • /
    • pp.1629-1640
    • /
    • 2015
  • This study was performed to compare carcass traits, sensory characteristics, physiochemical composition, and contents of nucleotides, collagen, and free amino acids among quality grades (QG) and to understand the association between QG and above parameters in loin and rump of Korean cattle steer. Loin and rump samples were obtained from 48 Korean cattle steers with each of four QG (QG 1++, 1+, 1, and 2; average 32 months of age). Carcass weight and marbling score (MS) were highest in QG 1++, whereas texture score measured by a meat grader was highest in QG 2. A correlation analysis revealed that MS (r = 0.98; p<0.01) and fat content (r = 0.73; p<0.01) had strong positive correlations with QG and that texture had a strong negative correlation (r = -0.78) with QG. Fat content in loin was highest but protein and moisture contents were lowest in QG 1++. Our results confirmed that a major determinant of QG is the MS; thus, intramuscular fat content. The International Commission on Illumination $L^*$, $a^*$, and $b^*$ values in loin were highest in QG 1++. Numeric values of shear force in loin were lowest in QG 1++, whereas those of tenderness, juiciness, and overall acceptability tended to be highest in QG 1++ without statistical significance. QG was strongly correlated with juiciness (r = 0.81; p<0.01) and overall acceptability (r = 0.87; p<0.001). All sensory characteristics were higher (p<0.05) in loin than those in rump. Adenosine-5'-monophosphate (AMP) and inosine-5'-monophosphate (IMP) contents in both loin and rump did not differ among QGs. No nucleotide (AMP, IMP, inosine, hypoxanthine) was correlated with any of the sensory traits. Total, soluble, and insoluble collagen contents in loin were higher in QG 1++ than those in QG 1. All three collagens had lower content in loin than that in rump. All three collagens were positively correlated with tenderness, juiciness, and overall acceptability. Glutamic acid content did not significantly differ among the four QGs in either loin or rump. In conclusion, it is confirmed that QG is associated with sensory traits but nucleotide contents in beef may not be a major factor determining meat palatability in the present study.

Development of nutrigenomic based precision management model for Hanwoo steers

  • Chandima Gajaweera;Dong Hun Kang;Doo Ho Lee;Yeong-Kuk Kim;Bo Hye Park;Sun Sik Chang;Ui Hyung Kim;Seung Hwan Lee;Ki Yong Chung
    • Journal of Animal Science and Technology
    • /
    • v.65 no.3
    • /
    • pp.596-610
    • /
    • 2023
  • Focusing high marble deposition, Hanwoo feedlot system uses high-energy diet over the prolonged fattening period. However, due to the individual genetic variation, around 40% of them are graded into inferior quality grades (QG), despite they utilized the same resources. Therefore, focusing on development of a nutrigenomic based precision management model, this study was to evaluated the response to the divergent selection on genetic merit for marbling score (MS), under different dietary total digestible nutrient (TDN) levels. Total of 111 calves were genotyped and initially grouped according to estimated breeding value (high and low) for marbling score (MS-EBV). Subsequently, managed under two levels of feed TDN%, over the calf period, early, middle, and final fattening periods following 2 × 2 factorial arrangement. Carcasses were evaluated for MS, Back fat thickness (BFT) and Korean beef quality grading standard. As the direct response to the selection was significant, the results confirmed the importance of initial genetic grouping of Hanwoo steers for MS-EBV. However, dietary TDN level did not show an effect (p > 0.05) on the MS. Furthermore, no genetic-by-nutrition interaction for MS (p > 0.05) was also observed. The present results showed no correlation response on BFT (p > 0.05), which indicates that the selection based on MS-EBV can be used to enhance the MS without undesirable effect on BFT. Ultimate turnover of the Hanwoo feedlot operation is primarily determined by the QGs. The present model shows that the initial grouping for MS-EBV increased the proportion of carcasses graded for higher QGs (QG1++ and QG1+) by approximately 20%. Moreover, there appear to be a potential to increase the proportion of QG 1++ animals among the high-genetic group by further increasing the dietary energy content. Overall, this precision management strategy suggests the importance of adopting an MS based initial genetic grouping system for Hanwoo steers with a subsequent divergent management based on dietary energy level.

The Relationships between Muscle Fiber Characteristics, Intramuscular Fat Content, and Fatty Acid Compositions in M. longissimus lumborum of Hanwoo Steers

  • Joo, Seon-Tea;Joo, Sung-Hyun;Hwang, Young-Hwa
    • Food Science of Animal Resources
    • /
    • v.37 no.5
    • /
    • pp.780-786
    • /
    • 2017
  • The objective of this study was to investigate the relationship between muscle fiber characteristics, intramuscular fat (IMF) content, and fatty acids composition in longissimus lumborum (LL) muscle from Hanwoo steers. The LL muscles were obtained from four quality grades (QG) carcasses and subjected to histochemical analysis. There were significant (p<0.05) differences in fiber number percentage (FNP) and fiber area percentage (FAP) of muscle fiber types among muscles from four QGs. Both FNP and FAP of type I increased while those of type IIB decreased with increasing QG from QG 2 to QG $1^{{+}{+}}$ (p<0.05). Also, with increasing QG, the saturated fatty acid (SFA) proportion decreased while monounsaturated fatty acid (MUFA) increased significantly (p<0.05). IMF content was positively correlated with both FNP and FAP of type I, but negatively correlated with those of type IIB. The proportions of SFA and MUFA were significantly (p<0.001) correlated with both type I and IIB composition. These results implied that muscle fiber type composition is an important factor influencing fatty acid composition in LL muscle of Hanwoo steer.

Seasonal Variation in Carcass Characteristics of Korean Cattle Steers

  • Piao, M.Y.;Baik, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.3
    • /
    • pp.442-450
    • /
    • 2015
  • Climate temperature affects animal production. This study was conducted to evaluate whether climatic conditions affect beef carcass characteristics of Korean cattle steers. The monthly carcass characteristics of Korean cattle steers (n = 2,182,415) for 8 yr (2006 through 2013) were collected from the Korean Institute for Animal Products Quality Evaluation. Daily climate temperature (CT) and relative humidity (RH) data were collected from the Korean Meteorological Administration. Weather conditions in South Korea during summer were hot and humid, with a maximum temperature of $28.4^{\circ}C$ and a maximum RH of 91.4%. The temperature-humidity index (THI), calculated based on CT and RH, ranges from 73 to 80 during summer. Winter in South Korea was cold, with a minimum temperature of $-4.0^{\circ}C$ and a wind-chill temperature of $-6.2^{\circ}C$. Both marbling score (MS) and quality grade (QG) of Korean cattle steer carcasses were generally best (p<0.05) in autumn and worst in spring. A correlation analysis showed that MS and QG frequencies were not associated (p>0.05) with CT. Yield grade (YG) of Korean cattle steer carcasses was lowest (p<0.05) in winter (November to January) and highest in spring and summer (May to September). A correlation analysis revealed that YG frequency was strongly correlated ($r{\geq}0.71$; p<0.01) with CT and THI values. The rib eye area, a positive YG parameter, was not associated with CT. Backfat thickness (BT), a negative YG factor, was highest in winter (November and December). The BT was strongly negatively correlated ($r{\leq}-0.74$; p<0.01) with CTs. Therefore, the poor YG during winter is likely due in part to the high BT. In conclusion, YG in Korean cattle steer carcasses was worst in winter. QGs were not associated with winter or summer climatic conditions.