• Title/Summary/Keyword: Q-switch

Search Result 80, Processing Time 0.044 seconds

Effect of NiO spin switching on the Fe film magnetic anisotropy in epitaxially grown Fe/NiO/Ag(001) and Fe/NiO/MgO(001) systems

  • Kim, Won-Dong;Park, Ju-Sang;Hwang, Chan-Yong;Wu, J.;Qiu, Z.Q.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.366-366
    • /
    • 2010
  • Single crystalline Fe/NiO bilayers were epitaxially grown on Ag(001) and on MgO(001), and investigated by Low Energy Electron Diffraction (LEED), Magneto-Optic Kerr Effect (MOKE), and X-ray Magnetic Linear Dichorism (XMLD). We find that while the Fe film has an in-plane magnetization in both Fe/NiO/Ag(001) and Fe/NiO/MgO(001) systems, the NiO spins switch from out-of-plane direction in Fe/NiO/MgO(001) to in-plane direction in Fe/NiO/Ag(001). These two different NiO spin orientations generate remarkable different effects that the NiO induced magnetic anisotropy in the Fe film is much greater in Fe/NiO/Ag(001) than in Fe/NiO/MgO(001). XMLD measurement shows that the much greater magnetic anisotropy in Fe/NiO/Ag(001) is due to a 90o-coupling between the in-plane NiO spins and the in-plane Fe spins which causes a switching of the NiO spins during the Fe magnetization reversal.

  • PDF

High Repetition Wavelength-locked 878.6 nm LD Dual-end-pumped Nd:YVO4 1064 nm Laser

  • Li, Yue;Yu, Yong-Ji;Wang, Yu-Heng;Liu, Hang;Liu, He-Yan;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.582-588
    • /
    • 2018
  • A $Nd:YVO_4$ laser dual-end-pumped by a wavelength-locked 878.6 nm laser diode is presented. At the repetition rate of 500 KHz, the absorbed pump power of 58 W, an output power of 26.1 W at 1064 nm is obtained, corresponding to an optical-optical efficiency of 45%. The pulse width is 44.2 ns. Meanwhile, the effects of traditional 808 nm pumping and 878.6 nm dual-end-pumping on the output laser beam quality and pulse width are compared and analyzed in an experiment.

Development of Minimally Invasive Mid-infrared Lipolysis Laser System for Effective Fat Reduction

  • Lee, Ji-Young;Ryu, Han Young;Seo, Young-Seok
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.82-89
    • /
    • 2021
  • Background and Objectives Due to changes in diet and lifestyle, the number of obese people worldwide is steadily increasing. Obesity has an adverse effect on a healthy life, so it needs treatment and improvement. Research related to this is continuously being conducted. Materials and Methods The laser system to compact designed using 808 nm laser diode and Neodymium Yttrium orthovanadate generates a 1064 nm wavelength, the periodically polarized nonlinear crystal pumping laser beam. The pulsed 1064 nm wavelength beam passing through the AO Q-switch is used as the pumping light of the nonlinear optical crystal and is irradiated to the periodic polarized nonlinear optical crystal with a quasi-phase matching period. Nonlinear optical crystals use an oven to control the temperature to generate the desired 1980 nm and 2300 nm wavelengths. Results The 1980 nm and 2300 nm wavelengths generated by temperature control of nonlinear optical crystals are effective for lipolysis. A fiber catheter was used so that the laser could be directly irradiated to the fat cells. In particular, the new wavelength (1980 nm, 2300 nm) can increase the fat reduction effect with low energy (1.3 W). When a laser with a combination wavelength of 1980 nm and 2300 nm was used, an average lipolysis effect of 20% was obtained. Conclusion A mid-infrared lipolysis laser system with excellent absorption of fat and water has been developed. We conducted a princlinical study to confirm the efficacy and safety of the lipolysis laser system, and obtained good results for lipolysis with low energy.

Development and Performance Compensation of the Extremely Stable Transceiver System for High Resolution Wideband Active Phased Array Synthetic Aperture Radar (고해상도 능동 위상 배열 영상 레이더를 위한 고안정 송수신 시스템 개발 및 성능 보정 연구)

  • Sung, Jin-Bong;Kim, Se-Young;Lee, Jong-Hwan;Jeon, Byeong-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.573-582
    • /
    • 2010
  • In this paper, X-band transceiver for high resolution wideband SAR systems is designed and fabricated. Also as a technique for enhancing the performance, error compensation algorithm is presented. The transceiver for SAR system is composed of transmitter, receiver, switch matrix and frequency generator. The receiver especially has 2 channel mono-pulse structure for ground moving target indication. The transceiver is able to provide the deramping signal for high resolution mode and select the receive bandwidth for receiving according to the operation mode. The transceiver had over 300 MHz bandwidth in X-band and 13.3 dBm output power which is appropriate to drive the T/R module. The receiver gain and noise figure was 39 dB and 3.96 dB respectively. The receive dynamic range was 30 dB and amplitude imbalance and phase imbalance of I/Q channel was ${\pm}$0.38 dBm and ${\pm}$3.47 degree respectively. The transceiver meets the required electrical performances through the individual tests. This paper shows the pulse error term depending on SAR performance was analyzed and range IRF was enhanced by applying the compensation technique.

Development of Candida albicans Biofilms Is Diminished by Paeonia lactiflora via Obstruction of Cell Adhesion and Cell Lysis

  • Lee, Heung-Shick;Kim, Younhee
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.3
    • /
    • pp.482-490
    • /
    • 2018
  • Candida albicans infections are often problematic to treat owing to antifungal resistance, as such infections are mostly associated with biofilms. The ability of C. albicans to switch from a budding yeast to filamentous hyphae and to adhere to host cells or various surfaces supports biofilm formation. Previously, the ethanol extract from Paeonia lactiflora was reported to inhibit cell wall synthesis and cause depolarization and permeabilization of the cell membrane in C. albicans. In this study, the P. lactiflora extract was found to significantly reduce the initial stage of C. albicans biofilms from 12 clinical isolates by 38.4%. Thus, to assess the action mechanism, the effect of the P. lactiflora extract on the adhesion of C. albicans cells to polystyrene and germ tube formation was investigated using a microscopic analysis. The density of the adherent cells was diminished following incubation with the P. lactiflora extract in an acidic medium. Additionally, the P. lactiflora-treated C. albicans cells were mostly composed of less virulent pseudohyphae, and ruptured debris was found in the serum-containing medium. A quantitative real-time PCR analysis indicated that P. lactiflora downregulated the expression of C. albicans hypha-specific genes: ALS3 by 65% (p = 0.004), ECE1 by 34.9% (p = 0.001), HWP1 by 29.2% (p = 0.002), and SAP1 by 37.5% (p = 0.001), matching the microscopic analysis of the P. lactiflora action on biofilm formation. Therefore, the current findings demonstrate that the P. lactiflora ethanol extract is effective in inhibiting C. albicans biofilms in vitro, suggesting its therapeutic potential for the treatment of biofilm-associated infections.

Thereshold Switching into Conductance Quantized Sttes in V/vamorphous- $V_{2}$ $O_{5}$/V Thin Film Devices (V/비정질- $V_{2}$ $O_{5}$ /lV 박막소자에서의 양자화된 컨덕턴스 상태로의 문턱 스위칭)

  • 윤의중
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.12
    • /
    • pp.89-100
    • /
    • 1997
  • This paper investigated a new type of low voltage threshold switch (LVTS). As distinguished from the many other types of electronic threshold switches, the LvTS is ; voltage controlled, occurs at low voltages ($V_{2}$ $O_{5}$lV devices. The average low threshold voltage < $V_{LVT}$>=218 mV (standard deviation =24mV~kT/q, where T=300K), and was independent of the device area (x100) and amorphous oxide occurred in an ~22.angs. thick interphase of the V/amorphous- $V_{2}$ $O_{5}$ contacts. At $V_{LVT}$ there was a transition from an initially low conductance (OFF) state into a succession of quantized states of higher conductance (ON). The OFF state was spatically homogeneous and dominated by tunneling into the interphase. The ON state conductances were consistent with the quantized conductances of ballistic transport through a one dimensional, quantum point contact. The temeprature dependence of $V_{LVT}$, and fit of the material parameters (dielectric function, barrier energy, conductivity) to the data, showed that transport in the OFF and ON states occurred in an interphase with the characteristics of, respectively, semiconducting and metallic V $O_{2}$. The experimental results suggest that the LVTS is likely to be observed in interphases produced by a critical event associated with an inelastic transfer of energy.rgy.y.rgy.

  • PDF

The Absorption Saturation and Diffraction Efficiency of the Permanent Gratings Due to the Photodarkening in Semiconductor Doped Glasses (반도체가 첨가된 유리의 암색화에 따른 포화흡수 변화와 영구 회절격자의 회절효율 연구)

  • Baek, Sung-Hyun;Shin, Sang-Hoon;Kim, Sang-Cheon;Choi, Moon-Goo;Park, seung-Han;Kim, Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.331-336
    • /
    • 1995
  • The steady-state absorption saturation of the photodarkend SDG was investigated. The absorption saturation intensity was observed to increase for the photodarkened sample. The diffraction efficiency of the permanent grating due to photodarkening was also measured using the backward DFWM technique. For the low backward pump intensity, the diffraction efficiency was proportional to the intensity of the pump beam. The origin of increasing diffraction efficiency is attributed to the difference in absorption between the permanent gratings created by photodarkening. ening.

  • PDF

Corrosion visualization under organic coating using laser ultrasonic propagation imaging

  • Shi, Anseob;Park, Jinhwan;Lee, Heesoo;Choi, Yunshil;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.301-309
    • /
    • 2022
  • Protective coatings are most widely used anticorrosive structures for steel structures. The corrosion under the coating damages the host material, but this damage is completely hidden. Therefore, a field-applicable under-coating-corrosion visualization method has been desired for a long time. Laser ultrasonic technology has been studied in various fields as an in situ nondestructive inspection method. In this study, a comparative analysis was carried out between a guided-wave ultrasonic propagation imager (UPI) and pulse-echo UPI, which have the potential to be used in the field of under-coating-corrosion management. Both guided-wave UPI and pulse-echo UPI were able to successfully visualize the corrosion. Regarding the field application, the guided-wave UPI performing Q-switch laser scanning and piezoelectric sensing by magnetic attachment exhibited advantages owing to the larger distance and incident angle in the laser measurement than those of the pulse-echo UPI. Regarding the corrosion visualization methods, the combination of adjacent wave subtraction and variable time window amplitude mapping (VTWAM) provided acceptable results for the guided-wave UPI, while VTWAM was sufficient for the pule-echo UPI. In addition, the capability of multiple sensing in a single channel of the guided-wave UPI could improve the field applicability as well as the relatively smaller size of the system. Thus, we propose a guided-wave UPI as a tool for under-coating-corrosion management.

Effectiveness of CO2 Fractional Laser on Linear Scars in Children

  • Ji, So young;Lee, Wu Seop;Yang, Wan Suk;Kim, Yong-Min;Baik, Bong Soo
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Background and Objectives A facial laceration is a commonly occurring trauma of children. In addition, appropriate treatment and scar management are very important because the psychosocial impact of facial scars is much greater in children than in adults. Materials and Methods In the authors' hospital, primary closure was conducted targeting a total of 8,924 patients from January 2015 to December 2017. Of these, scar management was conducted on 808 people using a CO2 fractional laser and Q-Switch Nd:YAG laser. To prove the effectiveness of the laser treatment on the linear scar, the patients were divided retrospectively into children and adults and sub-divided into those who received the treatment and those who did not. The subjective satisfaction of patients was evaluated using the Numeric Rating System (NRS). The objective scar scoring was evaluated using the image panel assessment based on the Vancouver Scar Scale (VSS), and the scoring was made by averaging the evaluations of three plastic surgeons. Results Evaluated NRS showed 8.50 ± 1.83 for adults without a laser, 8.51 ± 1.47 for adults with a laser, 7.93 ± 2.10 for children without a laser, and 8.9 ± 1.24 for children with a laser. The image panel assessment revealed 7.06 ± 1.31 for adults without a laser, 6.40 ± 2.37 for adults with a laser, 6.86 ± 1.45 for children without a laser, and 5.93 ± 1.21 for children with a laser. Conclusion When the linear scar is managed using a CO2 Fractional laser, it can be managed in children better than adults, which is believed to be useful because it leads to better satisfaction and prognosis.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.