• Title/Summary/Keyword: Pyrex glass

Search Result 104, Processing Time 0.019 seconds

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater (Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징)

  • 심영대;신규호;좌성훈;김용준
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • In this project, the efficiency of localized heating for micro systems packaging is developed by using a forced potential scheme microheater. Less than 0.2 Mpa contact pressure was used for bonding with a 200 mA current input for $50{\mu}m$ width, $2{\mu}m$ height and $8mm{\times}8mm$, $5mm{\times}5mm$, $3mm{\times}3mm$ sized phosphorus-doped poly-silicon microheater. The temperature can be raised at the bonding region to $800^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3 minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional microheaters. For performing the gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for conducting a gross leak check. The pass ratio of bonded dies was 67%, for conventional localized heating, and 85% for our newly developed FP scheme. The bonding strength was more than 25Mpa for FP scheme packaging, which shows that FP scheme can be a good candidate for micro-scale hermetic packaging.

  • PDF

Water Repellent Finishes of Polyester Fiber Using Glow Discharge (글로우방전을 이용한 폴리에스테르섬유의 발수가공)

  • Mo, Sang Young;Kim, Gi Lyong;Kim, Tae Nyun;Chun, Tae Il
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.29-41
    • /
    • 1993
  • In order to surface Hydrophobilization of Poly(ethylene terephthalate) (PET) fiber samples were treated in the atmosphere of CF$_{4}$ or $C_{2}$F$_{6}$glow discharge. The sample used in this study was PET film which is 75$\mu$m thick made by Teijin, O-Type(Japan). The cleaned samples were placed in plasma reactor made of pyrex glass cylinder, and plasma processing was carried out by glow discharge of CF$_{4}$ or $C_{2}$F$_{6}$ gas, being continuously fed by gas flow and continuously pumped out by a vacuum system. Electric power source for generate plasma state was sustained alternating current(60Hz) and voltage was sustained 600 volt. The duration of plasma treatment varied from 15 to 120 seconds except special case, the monomer gase pressure varied from 0.02 to 0.3 Torr and power range was 10 to 90 watts. The hydrophobic features of changed PET surface were evaluated by contact angle measurement and surface chemical characteristics were analyzed by ESCA. Results can be summerized as follows. 1. The most favorable setting position of substrate was the center area between the two electrodes. 2. $C_{2}$F$_{6}$ discharge current was lower than that of CF$_{4}$ when same voltage was sustained. Treated efficiency between CF$_{4}$ and $C_{2}$F$_{6}$ did not revealed significant differences under same electric power(wattage). 3. When monomer pressure is very low below 0.02 torr, as though substrate is exposed to CF$_{4}$ or $C_{2}$F$_{6}$ plasma, it tend to be hydrophilic through a little of fluorine bond and a great deal of oxidizing reaction. 4. There brought good hydrophobilization when monomer pressure was more 0.1 torr and duration of glow discharge treatment was over 45 seconds. When monomer pressure was too high, discharge current became low. Although prolong the duration, there was no more high hydrophobilization. 5. According to ESCA analysis, there were a little CF bond and a prevailing CF$_{2}$ bond in CF$_{4}$-treated substrate. There were CF$_{3}$, a little CF and a prevailing CF$_{2}$ bond in $C_{2}$F$_{6}$-treated substrate.d substrate.

  • PDF

Analysis of C-V Characteristics of MIS Structure Based on OTFT Technology for Flexible AM-OLED (Flexible AM-OLED를 위한 OTFT 기술 기반의 MIS 구조 C-V 특성 분석)

  • Kim, Jung-Seok;Kim, Byoung-Min;Chang, Jong-Hyeon;Ju, Byeong-Kwon;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.77-78
    • /
    • 2006
  • 최근 flexible OLED의 구동에 사용하기 위한 유기박막트랜지스터(Organic Thin Film Transistor, OTFT)의 연구에서는 용매에 용해되어 spin coating이 가능한 재료의 개발에 관심을 두고 있다. 현재 pentacene으로는 아직 spin coating으로 제작할 수 있는 상용화된 제품이 없고 spin coating이 가능한 활성층 물질(active material)로 P3HT가 쓰이고 있다. 본 연구에서는 용해 가능한 P3HT 활성층 물질과 여러 종류의 용해 가능한 게이트 절연물(gate insulator, Gl)을 사용하여 안정된 소자를 구현할 수 있는 공정을 개발하는 목적으로 metal-insulator-semironductor(MIS) 소자를 제작하여 C-V 특성을 측정하고 분석하였다. 먼저 7mm${\times}$7mm 크기의 pyrex glass 시편 위에 바닥 전극으로 $1600{\AA}$ Au을 증착하고 spin coating 방식을 이용하여 PVP, PVA, PVK, BCB, Pl의 5종류의 게이트 절연층을 각각 형성하였고 그 위에 같은 방법으로 P3HT를 코팅하였다. P3HT 코팅 시 bake 공정의 유무와 spin rpm의 변화에 따른 P3HT의 두께를 측정하였다. Gl의 종류별로 주파수에 따른 capatltancc를 측정하여 비교, 분석하였다. C-V 측정 결과 PVP, PVA, PVK, BCB, Pl의 단위 면적당 capacitance 값은 각각 1.06, 2.73, 2.94, 3.43, $2.78nF/cm^2$로 측정되었다. Threshold voltage, $V_{th}$는 각각 -0.4, -0.7, -1.6, -0.1, -0.2V를 나타냈다. 주파수에 따른 capacitance 변화율을 측정한 결과 Gl 물질 모두 주파수가 높을수록 capacitance가 점점 감소하는 경향을 보였으나 1${\sim}$2nF 이내의 범위에서 작은 변화율만 나타냈다. P3HT의 두께와 bake 온도를 변화시켜 C-V 값을 측정한 결과 차이는 없었다. FE-SEM으로 관찰한 결과에서도 두께나 온도에 따른 P3HT의 표면 morphology 차이를 확인할 수 없었다. 본 연구에서 PVK와 P3HT의 조합이 수율(yield)면에서 가장 안정적이면서 $3.43\;nF/cm^2$의 가장 높은 capacitance 값을 나타내고 $V_{th}$ 값 또한 -1.6V로 가장 낮은 값을 보였다.

  • PDF