• 제목/요약/키워드: Push-out Test

검색결과 207건 처리시간 0.023초

CLT-콘크리트 합성 거동을 위한 전단 연결재 부재 실험과 해석 연구 (Experimental and Analytical Study of Shear Connectors for the CLT-Concrete Composite Floor System)

  • 박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.65-73
    • /
    • 2019
  • This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is $90^{\circ}$ and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.

Perfobond rib 전단연결재가 설치된 강.콘크리트 합성보의 정적거동 (Static Behavior of Steel-Concrete Composite Beam with Perfobond Rib Shear Connector)

  • 안진희;정하민;김상효
    • 한국강구조학회 논문집
    • /
    • 제21권4호
    • /
    • pp.421-432
    • /
    • 2009
  • 본 연구는 perfobond rib 전단연결재를 사용한 합성보의 정적거동 특성을 파악하기 위하여 perfobond rib 전단연결재의 push-out 실험과 perfobond rib 전단연결재를 설치한 합성보의 하중재하 실험을 실시하였다. Perfobond rib의 전단저항성능은 콘크리트 강도 증가에 의한 콘크리트 선단지지력 및 콘크리트 다웰의 전단저항 성능 증가로 콘크리트 강도에 비례하며 횡방향 철근의 휨변형 성능에 대한 제한으로 연성효과를 나타내는 상대슬립은 일정 콘크리트 강도이상에서는 증가하지 않았다. 합성보의 하중재하 실험결과, 합성보에 휨 하중과 휨 전단하중이 동시에 작용하게 되므로 rib 홀에 배치된 횡방향 철근과 콘크리트 다웰부의 전단저항에 따라 합성보 콘크리트 슬래브의 rib 홀의 위치에서 횡방향 균열이 발생하였으며, perfobond rib 배치방법에 따라 합성단면 경계에서의 상대변위로 강성전단연결재의 전단거동 특성을 확인하였다. Perfobond rib와 같이 합성보에 대한 전단저항 성능이 큰 강성 전단연결재의 경우 전단연결재에 의한 합성보의 거동이 변화하므로 합성보 단면설계시 이에 대한 고려가 필요하다.

Study on bond behavior of steel reinforced high strength concrete after high temperatures

  • Chen, Zongping;Zhou, Ji;Wang, Xinyue
    • Advances in concrete construction
    • /
    • 제10권2호
    • /
    • pp.113-125
    • /
    • 2020
  • This paper presents experimental results on bond-slip behavior of steel reinforced high-strength concrete (SRHC) after exposure to elevated temperatures. Three parameters were considered in this test: (a) high temperatures (i.e., 20℃, 200℃, 400℃, 600℃, 800℃); (b) concrete strength (i.e., C60, C70, C80); (c) anchorage length (i.e., 250 mm, 400 mm). A total of 17 SRHC specimens subjected to high temperatures were designed for push out test. The load-slip curves at the loading end and free end were obtained, the influence of various variation parameters on the ultimate bond strength and residual bond strength was analyzed, in addition, the influence of elevated temperatures on the invalidation mechanism was researched in details. Test results show that the shapes of load-slip curves at loading ends and free ends are similar. The ultimate bond strength and residual bond strength of SRHC decrease first and then recover partly with the temperature increasing. The bond strength is proportional to the concrete strength, and the bond strength is proportional to the anchoring length when the temperature is low, while the opposite situation occurs when the temperature is high. What's more, the bond damage of specimens with lower temperature develops earlier and faster than the specimens with higher temperature. From these experimental findings, the bond-slip constitutive formula of SRHC subjected to elevated temperatures is proposed, which fills well with test data.

이중합성 교량의 복합스터드 전단연결부의 정적강도 평가 (Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges)

  • 김현호;심창수;윤광중;이필구
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.549-559
    • /
    • 2005
  • 철도교는 강성이 주요한 설계인자이기 때문에 기존의 2거더 교량의 구조적 효율성을 높이기 위해서 이중합성 구조를 가진 철도교를 제안하였다. 일반적으로 강합성 연속교를 설계할 경우, 부모멘트 구간에 존재하는 콘크리트 바닥판은 인장에 저항하지 못한다고 가정하고 바닥판 단면을 무시하게 된다. 부모멘트 구간에서는 합성단면의 강성이 감소하게 되므로 이를 보완하기 위해 강재단면이 커지게 되는데, 이러할 경우 변단면의 적용이 불가피하게 되고 강합성형으로서의 장점이 반감된다고 할 수 있다. 이와 같은 문제점을 해결하기 위한 다양한 접근법이 존재하지만 그 중에서도 경간을 확대하고 강성이 중요한 설계인자가 되는 경우에 적절하게 사용될 수 있도록 제안된 교량의 형태가 이중합성구조이다. 따라서 본 연구에서는 이중합성 전단연결부의 거동을 파악하기 위하여 수평스터드, 수평스터드와 수직스터드가 함께 배치된 복합스터드 부재에 대한 push-out 실험을 수행하였다. 실험결과의 분석을 통하여 기존의 설계식과의 비교를 수행하고 정적 거동을 평가하였다.

Mechanically fastened shear connectors in prefabricated concrete slabs - experimental analysis

  • Gluhovic, Nina;Markovic, Zlatko;Spremic, Milan;Pavlovic, Marko
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.369-381
    • /
    • 2020
  • Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen's layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.

레이저 표면처리에 의한 수산화아파타이트 코팅된 타이타니움합금 경계면의 결합에너지 (Interfacial bonding Energy between Laser Surface Treated HA layer and Ti alloy)

  • 문덕수;김영곤;남상용;조현설;허은정;김석영;이준희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.35-38
    • /
    • 1997
  • The interfacial bonding energy between laser surface treated HA layer and Ti alloy substrate was investigated using a mechanical push-out tester. The initial slope of shear-stress and reduced displacement curves, maximum interfacial bond strength and bonding energy were calculated from results of the push-out test. The calculated initial slpoes are 38 MPa for the Ti alloy(A), 65 MPa for the sandblast finished specimen(B), 95 MPa for the HA plasma spray coated specimen and 49 MPa for the laser surface treated specimen(D). The maximum interfacial bonding strength are 3 MPa for the A, 19 MPa for the B, 20 MPa for the C, 10 MPa for the D. The interfacial bonding energies are $3.3\times10^{-9}J/mm^2$ for the A, $15.5\times10^{-9}J/mm^2$ for the B, $15.6\times10^{-9}J/mm^2$ for the C and $18.3\times10^{-9}J/mm^2$ for the D. Microscopic observation shows that the breaking of the laser treated specimen had been occured through the boundary between HA layer and polymer resin, but the untreated specimen had been occured through the inside of HA coating layer.

  • PDF

새로운 FRP-콘크리트 전단부착성능 평가법을 활용한 최적 FRP 규사코팅 조건에 관한 연구 (A study on the optimum condition of FRP coarse-sand coating by using a new testing method for shear bearing capacity of FRP-concrete interface)

  • 이규필;신휴성;김승한
    • 한국터널지하공간학회 논문집
    • /
    • 제13권3호
    • /
    • pp.277-289
    • /
    • 2011
  • 본 연구에서는 압축력을 받는 터널 라이닝 부재 특성에 보다 부합된 조건에서 FRP-콘크리트 접촉면의 전단 저항력을 평가할 수 있는 새로운 시험법을 제안하였으며, 제안 시험법은 기존 시험방법에 비해 시험체 제작과 시험방법이 매우 용이하다. 제안된 시험법을 기반으로 FRP와 콘크리트 복합소재의 전단저항성능을 좌우하는 규사코팅의 최적조건을 도출하기 위한 매개변수 연구를 실시하였다. 다양한 시료에 대한 시험결과를 기존 연구결과와의 비교분석을 통하여 제안 시험법의 타당성을 보였으며, FRP부재와 콘크리트 접촉면의 전단저항을 극대화 시킬 수 있는 효과적인 규사입경 및 밀도에 대한 최적 조건을 제시하였다.

Behavior of grouped stud shear connectors between precast high-strength concrete slabs and steel beams

  • Fang, Zhuangcheng;Jiang, Haibo;Chen, Gongfa;Dong, Xiaotong;Shao, Tengfei
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.837-851
    • /
    • 2020
  • This study aims to examine the interface shear behavior between precast high-strength concrete slabs with pockets and steel beam to achieve accelerated bridge construction (ABC). Twenty-six push-out specimens, with different stud height, stud diameter, stud arrangement, deck thickness, the infilling concrete strength in shear pocket (different types of concrete), steel fiber volume of the infilling concrete in shear pocket concrete and casting method, were tested in this investigation. Based on the experimental results, this study suggests that the larger stud diameter and higher strength concrete promoted the shear capacity and stiffness but with the losing of ductility. The addition of steel fiber in pocket concrete would promote the ductility effectively, but without apparent improvement of bearing capacity or even declining the initial stiffness of specimens. It can also be confirmed that the precast steel-concrete composite structure can be adopted in practice engineering, with an acceptable ductility (6.74 mm) and minor decline of stiffness (4.93%) and shear capacity (0.98%). Due to the inapplicability of current design provision, a more accurate model was proposed, which can be used for predicting the interface shear capacity well for specimens with wide ranges of the stud diameters (from13 mm to 30 mm) and the concrete strength (from 26 MPa to 200 MPa).

모형실험을 통한 모래지반에서 석션버켓기초의 관입저항력 평가 (Investigation on the Penetration Resistance of Suction Bucket Foundation in Sand using Model Test)

  • 김근수;권오순;오명학;장인성
    • 한국지반환경공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.75-83
    • /
    • 2014
  • 석션버켓기초는 펌프로 버켓 내부의 물을 외부로 배출할 때 발생한 압력차로 지반에 설치되는 기초이다. 버켓기초는 외해의 플랫폼이나 석유 가스 시추시설을 계류시키기 위한 앵커로 주로 사용되었으나, 최근 유럽을 중심으로 해상풍력발전의 기초로 적용되기 시작하면서 국내에서도 큰 관심을 받고 있다. 석션버켓기초의 관입저항력 산정은 석션버켓기초를 성공적으로 시공하기위해 고려해야 할 주요 사항 중의 하나이다. 본 연구는 석션버켓기초를 관입시킬 때 필요한 관입력을 평가하기 위해 실내모형실험을 수행하였다. 실내모형실험은 압입설치 및 석션설치에서 측정한 관입저항력을 관입성능평가에서 많이 사용되는 기존의 이론식과 비교하여 강도감소계수의 적절한 범위를 검토하였다.

Effect of ultrasonic cleaning on the bond strength of fiber posts in oval canals filled with a premixed bioceramic root canal sealer

  • Bengoa, Fernando Pena;Arze, Maria Consuelo Magasich;Noguera, Cristobal Macchiavello;Moreira, Luiz Felipe Nunes;Kato, Augusto Shoji;Da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.19.1-19.8
    • /
    • 2020
  • Objective: This study aimed to evaluate the effect of ultrasonic cleaning of the intracanal post space on the bond strength of fiber posts in oval canals filled with a premixed bioceramic (Bio-C Sealer [BIOC]) root canal sealer. Materials and Methods: Fifty premolars were endodontically prepared and divided into 5 groups (n = 10), based on the type of root canal filling material used and the post space cleaning protocol. A1: gutta-percha + AH Plus (AHP) and post space preparation with ultrasonic cleaning, A2: gutta-percha + BIOC and post space preparation with ultrasonic cleaning, B1: gutta-percha + AHP and post space preparation, B2: gutta-percha + BIOC and post space preparation, C: control group. Fiber posts were cemented with a self-adhesive luting material, and 1 mm thick slices were sectioned from the middle and cervical third to evaluate the remaining filling material microscopically. The samples were subjected to a push-out test to analyze the bond strength of the fiber post, and the results were analyzed with the Shapiro-Wilk, Bonferroni, Kruskal-Wallis, and Mann-Whitney tests (p < 0.05). Failure modes were evaluated using optical microscopy. Results: The results showed that the fiber posts cemented in canals sealed with BIOC had lower bond strength than those sealed with AHP. The ultrasonic cleaning of the post space improved the bond strength of fiber posts in canals sealed with AHP, but not with BIOC. Conclusions: BIOC decreased the bond strength of fiber posts in oval canals, regardless of ultrasonic cleaning.