• 제목/요약/키워드: Purification network

검색결과 60건 처리시간 0.026초

상수처리시스템의 응집제 주입공정 모델링에 관한 연구 (A study on coagulant dosing process in water purification system)

  • 남의석;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.317-320
    • /
    • 1997
  • In the water purification plant, chemicals are injected for quick purification of raw water. It is clear that the amount of chemicals intrinsically depends on the water quality such as turbidity, temperature, pH and alkalinity etc. However, the process of chemical reaction to improve water quality by the chemicals is not yet fully clarified nor quantified. The feedback signal in the process of coagulant dosage, which should be measured (through the sensor of the plant) to compute the appropriate amount of chemicals, is also not available. Most traditional methods focus on judging the conditions of purifying reaction and determine the amounts of chemicals through manual operation of field experts or jar-test results. This paper presents the method of deriving the optimum dosing rate of coagulant, PAC(Polymerized Aluminium Chloride) for coagulant dosing process in water purification system. A neural network model is developed for coagulant dosing and purifying process. The optimum coagulant dosing rate can be derived the neural network model. Conventionally, four input variables (turbidity, temperature, pH, alkalinity of raw water) are known to be related to the process, while considering the relationships to the reaction of coagulation and flocculation. Also, the turbidity in flocculator is regarded as a new input variable. And the genetic algorithm is utilized to identify the neural network structure. The ability of the proposed scheme validated through the field test is proved to be of considerable practical value.

  • PDF

정수장 감시제어망의 관리와 보안개선을 위한 산업용 보안 L2스위치 개발 및 적용사례 (The development of industrial secure L2 switch and introduction example for management and security improvement of supervisory control network in purification plant)

  • 김윤하;유철;오은;김찬문;박익동;김용성;최현주
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.329-339
    • /
    • 2019
  • Recently, the advancement of information and communication technology(ICT) is expanding the connectivity through Internet of Things(IoT), and the media of connection is also expanding from wire/cable transmission to broadband wireless communication, which has significantly improved mobility. This hyperconnectivity has become a key element of the fourth industrial revolution, whereas the supervisory control network of purification plants in korea is operated as a communication network separated from the outside, thereby lagging in terms of connectivity. This is considered the best way to ensure security, and thus there is hardly any consideration of establishing alternatives to operate an efficient and stable communication network. Moreover, security for management of a commercialized communication network and network management solution may be accompanied by immense costs, making it more difficult to make new attempts. Therefore, to improve the conditions for the current supervisory control network of purification plants, this study developed a industrial security L2 switch that supports modbus TCP(Transmission Control Protocol) communication and encryption function of the transmission section. As a result, the communication security performance improved significantly, and the cost for implementing the network management system using Historical Trend and information of HMI(Human Machine Interface) could be reduced by approximately KRW 200 million. The results of this study may be applied to systems for gas, electricity and social safety nets that are infrastructure communication networks that are similar to purification plants.

A STUDY OF SIMULATION AND CONTROL OF PAC COSING PROCESS IN WATER PURIFICATION SYSTEM

  • Nahm, Euisuck;Lee, Subum;Woo, Kwangbang;Han, Taehan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.75-78
    • /
    • 1995
  • In this paper it is concerned to develop control method using jar-test results in order to predict the optimum dosage of coaglant, PAC(PoliAluminum Chloride). Considering the relations with the reactions with the reaction of coagulation and flocculation, the five independent variables ( e, g, turbidity of raw water, water turbidity in flocculators, temperature, pH, and alkalynity) are selected out of parameters and they are put into calculation to develop a neural network model for PAC dosing process in water purification system. This model is utilized to predict optimum dosage of PAC. That is, the optimum dosage of PAC is searched in neural network model for PAC dosing process to minimize the water turbidity in flocculators. This searching is implemented by means of expert heuristics. The efficacy of the proposed contorl schemem and feasibility of acquired neural network model for PAC dosing contorl in water purification system is evaluated by means of computer simulation.

  • PDF

네트워크 통합관리시스템과 보안스위치를 이용한 반송정수장 무선랜 구축사례 (The case study on wireless lan design technique for Bansong purification plant using network integrated management system and security switch)

  • 박은철;최현주
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.309-315
    • /
    • 2018
  • Currently, the commercialization of the $5^{th}$ Generation (5G) service is becoming more prevalent in domestic communication network technology. This has reduced communication delay time and enabled large-capacity data transmission and video streaming services in real-time. In order to keep pace with these developments, K-water has introduced a smart process control system in water purification plants to monitor the status of the water purification process. However, since wireless networks are based on the public Long Term Evolution (LTE) network, communication delay time remains high, and high-resolution video services are limited. This is because communication networks still have a closed structure due to expense and security issues. Therefore, with 5G in its current form, it is very difficult to accommodate future services without improving the infrastructure of its communication networks. In recognition of these problems, this study implemented the authentication and management function of wireless networks on a wired network management system in the K-water Bansong water purification plant. The results confirmed that wired Local Area Network (LAN) services give a higher security performance than an expensive commercial wireless LAN system. This was achieved by using an Internet Protocol (IP) address management system of wired networks and the packet filtering function of the Layer2 (L2) switch. This study also confirmed that it is possible to create a wireless LAN service that is 3.7 times faster than the existing LTE communication network.

신경회로망을 이용한 상수처리시스템의 응집제 주입공정 최적화 (Optimization of coagulant dosing process in water purification system using neural network)

  • 남의석;박종진;장석호;차상엽;우광방;이봉국;한태환;고택범
    • 제어로봇시스템학회논문지
    • /
    • 제3권6호
    • /
    • pp.644-651
    • /
    • 1997
  • In the water purification plant, chemicals are injected for quick purification of raw water. It is clear that the amount of chemicals intrinsically depends on water quality such as turbidity, temperature, pH and alkalinity. However, the process of chemical reaction to improve water quality (e.g., turbidity) by chemicals is not yet fully clarified nor quantified. The feedback signal in the process of coagulant dosage, which should be measured (through the sensor of the plant) to compute the appropriate amount of chemicals, is also not available. Most traditional methods focus on judging the conditions of purifying reaction and determine the amounts of chemicals through manual operation of field experts using Jar-test data. In this paper, a systematic control strategy is proposed to derive the optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride), using Jar-test results. A neural network model is developed for coagulant dosing and purifying process by means of six input variables (turbidity, temperature, pH, alkalinity of raw water, PAC feed rate, turbidity in flocculation) and one output variable, while considering the relationships to the reaction of coagulation and flocculation. The model is utilized to derive the optimum coagulant dosage (in the sense of minimizing turbidity of water in flocculator). The ability of the proposed control scheme validated through the field test has proved to be of considerable practical value.

  • PDF

원자로 냉각재 정화필터 및 밀봉수 주입필터 국산화 설계 (Design of Reactor Coolant Purification Filter and Seal Injection Filter)

  • 박종범;김동수;이주형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.476-478
    • /
    • 2000
  • Objective is to design a high performance purification filter system of reactor coolant and seal injection system at nuclear power station. The purification filter systems play an important role in the stability of the nuclear and volume control system which consist the primary network systems of the nuclear power station. But the users of the purification filter systems frequently suffer from high maintenance cost which comes from lack of understanding of the system technology and domestic suppliers. It is time to establish a high performance domestic filter system manufacturing technology and optimum design for wide use in industrial applications.

  • PDF

적대적 공격을 방어하기 위한 StarGAN 기반의 탐지 및 정화 연구 (StarGAN-Based Detection and Purification Studies to Defend against Adversarial Attacks)

  • 박성준;류권상;최대선
    • 정보보호학회논문지
    • /
    • 제33권3호
    • /
    • pp.449-458
    • /
    • 2023
  • 인공지능은 빅데이터와 딥러닝 기술을 이용해 다양한 분야에서 삶의 편리함을 주고 있다. 하지만, 딥러닝 기술은 적대적 예제에 매우 취약하여 적대적 예제가 분류 모델의 오분류를 유도한다. 본 연구는 StarGAN을 활용해 다양한 적대적 공격을 탐지 및 정화하는 방법을 제안한다. 제안 방법은 Categorical Entropy loss를 추가한 StarGAN 모델에 다양한 공격 방법으로 생성된 적대적 예제를 학습시켜 판별자는 적대적 예제를 탐지하고, 생성자는 적대적 예제를 정화한다. CIFAR-10 데이터셋을 통해 실험한 결과 평균 탐지 성능은 약 68.77%, 평균정화성능은 약 72.20%를 보였으며 정화 및 탐지 성능으로 도출되는 평균 방어 성능은 약 93.11%를 보였다.

상수처리시스템 응집제 주입공정 퍼지 모델링과 제어 (Fuzzy modeling and control for coagulant dosing process in water purification system)

  • 이수범;남의석;이봉국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.282-285
    • /
    • 1996
  • In the water purification plant, the raw water is promptly purified by injecting chemicals. The amount of chemicals is directly related to water quality such as turbidity, temperature, pH and alkalinity. At present, however, the process of chemical reaction to the turbidity has not been clarified as yet. Since the process of coagulant dosage has no feedback signal, the amount of chemical can not be calculated from water quality data which were sensed from the plant. Accordingly, it has to be judged and determined by Jar-Test data which were made by skilled operators. In this paper, it is concerned to model and control the coagulant dosing process using jar-test results in order to predict optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride). The considering relations to the reaction of coagulation and flocculation, the five independent variables(turbidity, temperature, pH, Alkalinity of the raw water, PAC feed rate) are selected out and they are put into calculation to develope a neural network model and a fuzzy model for coagulant dosing process in water purification system. These model are utilized to predict optimum coagulant dosage which can minimize the water turbidity in flocculator. The efficacy of the proposed control schemes was examined by the field test.

  • PDF

고도정수처리에 따른 상수도 공급과정에서의 소독부산물 농도 예측모델 개발 (Development of a Concentration Prediction Model for Disinfection By-product according to Introduce the Advanced Water Treatment Process in Water Supply Network)

  • 서지원;김기범;김기범;구자용
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.421-430
    • /
    • 2017
  • In this study, a model was developed to predict for Disinfection By-Products (DBPs) generated in water supply networks and consumer premises, before and after the introduction of advanced water purification facilities. Based on two-way ANOVA, which was carried out to statistically verify the water quality difference in the water supply network according to introduce the advanced water treatment process. The water quality before and after advanced water purification was shown to have a statistically significant difference. A multiple regression model was developed to predict the concentration of DBPs in consumer premises before and after the introduction of advanced water purification facilities. The prediction model developed for the concentration of DBPs accurately simulated the actual measurements, as its coefficients of correlation with the actual measurements were all 0.88 or higher. In addition, the prediction for the period not used in the model development to verify the developed model also showed coefficients of correlation with the actual measurements of 0.96 or higher. As the prediction model developed in this study has an advantage in that the variables that compose the model are relatively simple when compared with those of models developed in previous studies, it is considered highly usable for further study and field application. The methodology proposed in this study and the study findings can be used to meet the level of consumer requirement related to DBPs and to analyze and set the service level when establishing a master plan for development of water supply, and a water supply facility asset management plan.