• Title/Summary/Keyword: Pure tone audiometry

Search Result 60, Processing Time 0.025 seconds

Assessment of Noise Exposure and Hearing Loss Among Workers in Textile Mill (Thamine), Myanmar: A Cross-Sectional Study

  • Zaw, Aung K.;Myat, Aung M.;Thandar, Mya;Htun, Ye M.;Aung, Than H.;Tun, Kyaw M.;Han, Zaw M.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.199-206
    • /
    • 2020
  • Background: In a wide range of industries, noise-induced hearing loss remains one of the most prevalent occupational problems. This study aimed to assess the noise exposure level and associated factors of hearing loss among textile workers in Yangon Region, Myanmar. Methods: A cross-sectional study was conducted at a Textile mill (Thamine), Yangon Region, from April to December 2018. In total, 226 workers who were randomly selected from 3 weaving sections participated in face-to-face interviews using a structured questionnaire. A digital sound level meter and pure-tone audiometer were used for the assessment of noise exposure level and hearing loss, respectively. Logistic regression analysis was performed to assess the associated factors of hearing loss. Results: In total workers, 66.4% were exposed to ≥85 dB(A) of noise exposure, and the prevalence of hearing loss was 25.7%. Age ≥35 years, below high school education, hearing difficulty, tinnitus, hypertension, > 9 years of service duration in a textile mill were positively associated with hearing loss. After adjusting confounding factors, age ≥35 years (adjusted odds ratio = 6.90, 95% confidence interval = 3.45-13.82) and tinnitus (adjusted odds ratio = 2.88, 95% confidence interval = 1.13-7.37) were persistently associated with hearing loss. Conclusion: Providing occupational hazard education and enforcement of occupational safety regulations should be taken to decrease the noise exposure level. The regular audiometry test should be conducted for assessment of hearing threshold shift. The employer needs to implement a hearing conservation program in workplace when noise exposure reaches or exceeds 85 dB(A) for 8 hours.

Three Cases of Sudden Sensorineural Hearing Loss with Complete Recovery by Korean Medical Treatment (한방치료로 완전 청력회복을 보인 돌발성 난청 환자 치험 3례)

  • Kim, Su-Yeong;Kim, Kyung-Han;Ahn, Jae-Hyun;Hwang, Mi-Lee;Jea, Ha-Kyung;Jung, Hyun-A
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.32 no.3
    • /
    • pp.212-223
    • /
    • 2019
  • Objectives : The purpose of this study is to report three cases of Korean medical treatment for sudden sensorineural hearing loss(SSHL). Methods : This study conducted with three sensorineural hearing loss patients who hospitalized in Ophthalmology, Otolaryngology & Dermatology Clinic of Korean Medical Hospital. Three patients were treated with herbal medicine(Sunkihwalhyeol-tang, Ikgibohyeol-tang, Gongjindan) and acupuncture. After treatment, we evaluated Siegel's Criteria with pure tone audiometry and subjective symptoms alteration. Results : All three patients were completely recovery about Siegel's Criteria and improved subjective symptoms after treatment. Conclusions : This study suggests that Korean medical treatment may be effective about SSHL.

A preliminary study of sound quality evaluation of cochlear implant users (인공와우 사용자의 심리음향적 음질평가 예비연구)

  • Bahng, Junghwa;Oh, Soo Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • Sound quality evaluation is one of the psychoacoustic methods to measure subjective judgements for sound color. The purpose of this study is to investigate sound quality benefits of bimodal users by comparing sound quality scores between bimodal hearing condition and unilateral cochlear implant(CI) condition as a preliminary study. Thirteen bimodal users and seven unilateral CI users were participated in this study. Audiologists performed pure tone and speech audiometry and measured functional gain and real-ear insertion gain. Subjective assessment of sound quality was followed with four sounds including violin sound, male and female voices, and refrigerator noise. Participants judged the sound quality with six sound quality index. Bimodal users showed mean 0.8 points more sound quality improvements in bimodal condition than unilateral CI condition. Group comparison between bimodal and unilateral CI users showed no differences. A follow-up study of sound quality tools and methods should be considered to evaluate subjective bimodal benefits of cochlear implant users.

Clinical Factors Influencing the Trial and Purchase of Bilateral Microphones with Contralateral Routing of Signal in Patients with Asymmetric Sensorineural Hearing Loss

  • Seong, Jeon;Yang, Seung Koo;Jang, Pilkeun;Lee, Sang-Yeon;Carandang, Marge;Choi, Byung-Yoon
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2020
  • Background and Objectives: Bilateral microphones with contralateral routing of signal (BiCROS) hearing aid is an option for hearing rehabilitation in individuals with asymmetric sensorineural hearing loss (ASNHL). The clinical factors influencing the trial and purchase of BiCROS were investigated. Subjects and Methods: We reviewed the medical records of 78 patients with ASNHL who were recommended to use BiCROS and analyzed the demographic and audiological factors influencing the trial and purchase of BiCROS. Results: Among the 78 patients, 52 (66.7%) availed of the free BiCROS trial and 21 (26.9%) purchased BiCROS. The mean pure tone audiometry (PTA) air conduction (AC) threshold of the better- and worse-hearing ears were 44.2±12.8 dB and 90.7±22.5 dB HL, respectively. The decision for trial or purchase of BiCROS was not influenced by age, sex, duration of hearing loss of the worse-hearing ear, or PTA AC threshold or speech discrimination score of both ears. The first and third quartiles of the PTA AC thresholds for the better-hearing ear of BiCROS buyers were 38.75 dB and 53.75 dB HL, respectively. The counterpart values for the worse-hearing ear were 72.50 dB and 118.75 dB HL, respectively. Conclusions: The clinical factors analyzed in this study were found to be irrelevant to the trial and purchase of BiCROS in patients with ASNHL. Nevertheless, the distribution range of the auditory thresholds of the subjects using BiCROS can be a useful basis for the counseling of patients with ASNHL and selection of candidates for BiCROS use.

A Study for the Norms of Audiometric Tests in Koreans (정상한국인의 청력검사치에 관한 연구)

  • 오혜경;서장수;이근해;김희남;김영명;권영화;서옥기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.1-38
    • /
    • 1981
  • Currently in the otologic field, there are various methods of special audiometric examinations, such as, tone decay, SISI, and impedance audiometry and only a few studies has been done in these fields sporadically in Korea. The purpose of this paper is to establish norms of various special audiometric tests, so we have performed the special audiometric tests on 100 male medical students in good physical condition and the follow results were obtained. 1. All cases showed over 90% of PB scores. The mean and its 2 S.D. were 98$\pm$4.9% in the right ear and 97$\pm$5.6% in the left ear. 2. The mean and its 2 S.D. of MCL(most comfortable level) were 45$\pm$15.4 dB in the right ear and 46$\pm$17.9 dB in the left ear, and its range was 12$\pm$12.2 dB in the right ear and 13$\pm$12.6 dB in the left ear. 3. The mean and its 2 S.D. of UCL (uncomfortable level) were 102$\pm$7.9 dB in the right ear and 102$\pm$7.9 dB in the left ear and about an half in cases showed over 106 dB of UCL. 4. In 95% of cases, SISIs(short increment sensitivity index) at 1, 000 Hz and 4000 Hz was below 45% in the right ear in both frequencies and below 55% and 75% in the left ear, respectively. 5. In 95% of cases, tone decays at 2, 000 Hz and 4, 000 Hz was below 10 dB in both ears. 6. The difference between SRT and PTA (speech reception threshold minus pure tone average) was 4$\pm$9.2 dB in the right ear and 4$\pm$10.0 dB in the left ear. 7. The dynamic range(uncomfortable level minus speech reception threshold) was 98$\pm$13.5 dB in the right ear and 99$\pm$13.5 dB in the left ear. We had trouble in estimating the dynamic range in about an half in cases, in which we couldn't estimate the UCL with our conventional audiometry. 8. The results of impedance audiometric tests were as follow: A. In the tympanogram, all cases were of A type with one exception of B type in the left ear. The mean and its 2 S.D. of its peak level were 22.8$\pm$32.94mm $H_2O$ in the right ear and 23.9$\pm$29. 81mm $H_2O$ in the left ear. B. The mean and its 2 S.D. of the compliance were 0.6$\pm$0.54cc in the right ear and 0.6$\pm$0.53cc in the left ear. C. The results of stapedial reflex: a. The mean and its 2 S.D. of the controlateral stapedial reflex at 500Hz, 1, 000Hz, 2, 000Hz, 4, 000Hz were 99$\pm$17.7 dB, 87$\pm$14.4 dB, 79$\pm$13.7 dB, 77$\pm$20.0 dB in the right ear and 99$\pm$15.9 dB, 88$\pm$13.9 dB, 79$\pm$13.7 dB, 77$\pm$21.3 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wasn't generated in 6 cases in the right ear and 11 cases in the left ear. b. The mean and its 2 S.D. of the ipsilateral stapedial reflex at 1, 000Hz, and 2, 000Hz were 89$\pm$16.3 dB, 82$\pm$15.9 dB in the right ear and 89$\pm$18.0 dB, 83$\pm$18.9 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wans't generated in 1 case in the right ear and 2 cases in the left ear. 9. Eustachian tube function using with impedance audiometry was malfunctioned in21 cases depending on the tested pressure and the range of peak level of tympanogram was 14$\pm$26.9mm $H_2O$(tested pressure:+250mm $H_2O$), 8$\pm$21.9mm $H_2O$ (tested pressure:-250mm $H_2O$) in the right ear and 11 cases depending on the tested pressure and the range of the peak level of tympanogram was 12$\pm$22.5mm $H_2O$ (tested pressure: +250 mm $H_2O$, 9$\pm$17.3mm $H_2O$(tested pressure: -250mm $H_2O$) in the left ear.

  • PDF

The effect of temporomandibular joint movement on tinnitus (턱의 운동이 이명에 미치는 영향)

  • Kim, Jeong-Mo;Kim, Tae Su;Nam, Eui-Cheol
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.333-338
    • /
    • 2013
  • Purpose: A growing number of studies have been providing evidence for neural connections between the auditory and somatosensory systems that might be a critical part of the mechanisms underlying certain forms of tinnitus. The aim of this study was to investigate the effect of temporomandibular joint (TMJ) movements on tinnitus. Methods: One hundred sixty-three tinnitus patients participated in this study. All patients underwent a thorough audiological examination including pure-tone audiometry, tinnitus handicap inventory, and evaluation of tinnitus loudness, frequency and severity on a visual analog scale. Somatic testing consisting of nine forceful jaw muscle contractions was performed to evaluate the effect of TMJ movements on modulation of tinnitus. Results: 66.9% of patients had unilateral tinnitus. Somatic testing modulated tinnitus loudness in 125 ears (57.6 %) of 217 ears tested. An increase in tinnitus loudness was observed more often than a decrease. Loudness was most commonly increased by opening and clenching jaw. Tinnitus could be induced by opening, clenching and deviating jaw to the left. Conclusion: Our study showed evidence that TMJ movements may aggravate and even evoke tinnitus and somatic testing can be used for evaluating if stimulation of the TMJ induces or aggravates tinnitus.

Hearing Asymmetry among Occupationally Noise-exposed Workers (직업적으로 소음에 노출되는 근로자들에서 청력의 비대칭성)

  • Kim, Wook-Tae;Kim, Dae-Hwan;Lee, Chae-Kwan;Ahn, Jin-Hong;Lee, Chang-Hee;Kim, Hwi-Dong;Kim, Jeong-Ho;Son, Byung-Chul;Lee, Jong-Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Usually equal noise exposure is considered to cause symmetrical hearing loss, but some screening audiometries of employees who were exposed to noise showed asymmetry. Therefore, this study was carried out to evaluate the distribution of asymmetrical hearing loss and the difference of air conduction level between left and right ear at the different frequencies (500, 1,000, 2,000, 3,000, 4,000, 6,000 Hz). Study subjects were 326 male employees who had participated in the noise-specific health examination from May to October, 2002. They were evaluated by otoscopic examination, pure tone audiometry and tympanometry. In all frequencies, hearing threshold level of left ear was worse than right ear. The mean interaural threshold differences between two ears were 0.83 dB at 500 Hz, 1.18 dB at 2,000 Hz, 2.29 dB at 3,000 Hz, 2.18 dB at 4,000 Hz, and statistically significant (p<0.05). The hearing loss of left ear was greater than right ear in occupationally noise-exposed workers. It is believed that left ear was more susceptible to noise damage than right ear

Effects of the Personal Stereo System on Hearing in Adolescents (개인용 음향기기 사용이 청소년의 청력에 미치는 영향)

  • Park, Jong-Seo;Oh, Sean-Hee;Kang, Pock-Soo;Kim, Chang-Yoon;Lee, Kyeong-Soo;Hwang, Tae-Yoon;SaKong, Joon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • Objectives : This study was conducted to evaluate the effects of the personal stereo system on the hearing in adolescents. Methods : A total of 68 adolescents(age: 13-18 years) who visited the ENT Department at a University Hospital in Daegu were personally interviewed. The questionnaires were about general characteristics of the subjects, the time of personal stereo system use (year, hour) and place. Cumulative exposure to the personal stereo system was calculated by the product of the total years and the daily hours of their use. Pure tone audiometry was performed and the hearing threshold was measured at 500, 1000, 2000, 4000 and 8000 Hz. Results : The average time of using a personal stereo system a day was about 3 hours and 75% of the subjects used a personal stereo system for 2-5 years. The elevation of threshold was more prominent in the subjects who used personal stereo systems for 4 years and more compared with those subjects who used them for 3 years and under. The elevation of hearing threshold was also more prominent in the subjects who used personal stereo systems for 4 hours and more a day compared with those subjects who used personal stereo systems for 3 hours and under a day. The elevation of hearing threshold was more prominent in the subjects who used personal stereo systems for 13 hour. years and more compared to the subjects who used them 12 hour. years and under. Conclusions : These results suggest that the elevation of hearing threshold can happen to adolescents who used personal stereo systems for a long time. In order to prevent hearing loss, we need to teach adolescents appropriate usage of the personal stereo system and hearing tests should be included in the periodic school-based physical examination for the adolescents.

Clinical Factors Influencing the Trial and Purchase of Bilateral Microphones with Contralateral Routing of Signal in Patients with Asymmetric Sensorineural Hearing Loss

  • Seong, Jeon;Yang, Seung Koo;Jang, Pilkeun;Lee, Sang-Yeon;Carandang, Marge;Choi, Byung-Yoon
    • Korean Journal of Audiology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2020
  • Background and Objectives: Bilateral microphones with contralateral routing of signal (BiCROS) hearing aid is an option for hearing rehabilitation in individuals with asymmetric sensorineural hearing loss (ASNHL). The clinical factors influencing the trial and purchase of BiCROS were investigated. Subjects and Methods: We reviewed the medical records of 78 patients with ASNHL who were recommended to use BiCROS and analyzed the demographic and audiological factors influencing the trial and purchase of BiCROS. Results: Among the 78 patients, 52 (66.7%) availed of the free BiCROS trial and 21 (26.9%) purchased BiCROS. The mean pure tone audiometry (PTA) air conduction (AC) threshold of the better- and worse-hearing ears were 44.2±12.8 dB and 90.7±22.5 dB HL, respectively. The decision for trial or purchase of BiCROS was not influenced by age, sex, duration of hearing loss of the worse-hearing ear, or PTA AC threshold or speech discrimination score of both ears. The first and third quartiles of the PTA AC thresholds for the better-hearing ear of BiCROS buyers were 38.75 dB and 53.75 dB HL, respectively. The counterpart values for the worse-hearing ear were 72.50 dB and 118.75 dB HL, respectively. Conclusions: The clinical factors analyzed in this study were found to be irrelevant to the trial and purchase of BiCROS in patients with ASNHL. Nevertheless, the distribution range of the auditory thresholds of the subjects using BiCROS can be a useful basis for the counseling of patients with ASNHL and selection of candidates for BiCROS use.

A Case of Chronic Meniere's Disease Improved by Korean Medicine Treatment Including Pharmacoacupuncture of Cervical and Temporomandibular Area - A Case Report (경추부 및 하악부 약침 치료를 포함한 한의복합치료로 호전된 만성 메니에르병 환자 1례 - 증례 보고)

  • Dong-Joo Kim;Kyeong-Hwa Heo;Kyeong-Hwa Lee;Hye-Jin Lee;Seung-Yeon Cho;Jung-Mi Park;Chang-Nam Ko;Seong-Uk Park
    • The Journal of Korean Medicine
    • /
    • v.44 no.3
    • /
    • pp.150-162
    • /
    • 2023
  • Meniere's disease is characterized by episodic vertigo, fluctuating hearing loss, tinnitus and ear fullness. The main pathological finding is endolymphatic hydrops, but the etiology of disease and effective treatment methods are still disputed. Recently, Cervical spine disorders(CSD) and Temporomandibular disorders(TMD) have been attracting attention as one of the causes of Meniere's disease. A 65-year-old female Meniere patient with musculoskeletal problems in the cervical and mandible area was treated by Korean medical therapies including pharmacoacupuncture treatment. After 5 weeks of treatment, there was no meaningful change in hearing level evaluated with pure tone audiometry, but the subjective symptoms of Meniere improved significantly. Numerical rating scale (NRS) decreased from 10 to 0 for hearing loss, 10 to 3 for tinnitus and 8 to 3 for ear fullness. Also NRS of cervicalgia was reduced from 5 to 0 after treatment. The result suggests that the Korean medical therapy including pharmacoapuncture targeting CSD and TMD could be safe and effective method for patients with Meniere's disease.