• Title/Summary/Keyword: Pure Titanium

Search Result 330, Processing Time 0.029 seconds

Recovery of Pure Electrolytic Iron from Wasted Hydrochloric Pickling Solution of Steel (철강의 염산산세 폐액으로부터 전해철의 제조에 관한 연구)

  • 김기호;권오익;홍성규
    • Journal of the Korean institute of surface engineering
    • /
    • v.26 no.1
    • /
    • pp.23-30
    • /
    • 1993
  • Iron component in wasted hydrochloric etching solutions from steel works were recovered by electrolysis. The electric conductances of the solutions, as the function of the bath temperature and the ferrousion concen-tration, were measured and the result of the original solution was K=(0.0012+0.0005$\times$10-3T-0.1160$\times$10-6T2)$\times$102S.m-1(T in $^{\circ}C$) The current efficiency was better for the bath using a soluble steel plate anode than for the bath using an insoluble platinized titanium one. Densed electrolytic iron having the purity of higher than 99.99% was ob-tained at the electrolysis conditions of the cathodic current density of 15A/dm2, the bath temperature of $70\pm$$5^{\circ}C$ and the ferrous ion concentration of about 100g/l. The morphologies of the deposited iron were observed by SEM.

  • PDF

Effects of Nb Addition on Microstructure and Oxidation Behavior of Ti Alloy (Nb이 첨가된 Ti합금의 미세 조직 및 산화 거동)

  • 이도재;이광민;이경구;박범수;김수학;전충극;윤계림
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.1
    • /
    • pp.58-63
    • /
    • 2004
  • The oxidation behavior of Ti-Nb alloys was studied in dry atmosphere. After vacuum arc melting and hot rolling treatment, Ti-Nb alloys were oxidized at $450^{\circ}C$$750^{\circ}C$. The oxidation behaviors between matrix and oxide scale were analyzed by SEM, XPS and XRD. Ti-Nb alloys had higher oxidation resistance than pure Ti at $750^{\circ}C$. XPS analysis of oxide film revealed that $TiO_2$ oxide was formed on the top of surface. The weight gains during the oxidation increase rapidly at temperature above $600^{\circ}C$ which obey the parabolic law.

Pure inorganic scratch resistive layer on the titanium and the stainless steel surfaces by a sol-gel coating method (졸-겔 코팅법에 의한 티타늄과 스테인리스표면위의 무기질 내스크래치 보호막)

  • Kim, Ho-Hyeong;Kim, Gyun-Tak;Lee, Heung-Ryeol;Hwang, Tae-Jin
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.198-199
    • /
    • 2009
  • 티타늄과 스테인리스 기판위에 졸-겔 코팅법으로 무기질 보호막을 형성하였고 기계적 특성을 테스트 하였다. 무기질 보호막은 금속 표면위에 졸-겔 코팅용액을 스프레이 코팅하여 제작하였다. 티타늄과 스테인리스 기판위에 적용한 무기질 보호막은 현저한 내스크래치성 향상을 보였다. 또한 실리카 나노입자의 첨가에 따른 무기질 보호막의 경도 향상을 보였다. 그러나 실리카 나노입자가 2 wt% 이상 첨가됨에 따라 보호막의 경도가 감소함을 알 수 있었다.

  • PDF

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

Healing of the bone around pure titanium implants without primary bone contact (초기 골 접촉이 없는 순수 티타늄 임프란트 주위 골의 치유반응)

  • Ahn, Jae-Hyun;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.233-249
    • /
    • 1999
  • Primary fixation is one of the most important factor in establishing adequate osseointegration between implant and bone. To evaluate the initial healing response of bone around implants without primary bone contact, this study was designed to create considerable space between implant and bone in 5 mongrel dogs, about 1-year old. After 3 holes of 6.0mm in diameter were prepared at the femur neck of the dogs, commercially pure titanium thread type implants(STERI-$OSS^{(R)}$), 8mm in length and 3.8mm, 5.0mm and 6.0mm in diameter, were inserted. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), and the penetration of upper soft tissue into the gap was inhibited by it. The each implant was positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 were inserted in 2 dogs for mobility test and removal torque test.Fluorescent dyes were injected in order of Doxycycline, Alizarin Red S, and Calcein at intervals of 2 weeks. At 4-, 8-, and 12-week after placement, 3 dogs were sacrificed for histologic observation, and at 8- and 12-week after placement, 2 dogs were sacrificed for mobility test using $Periotest^{(R)}$ (Simens AG, Bensheim, Germany) and torque test using Autograph AGS-1000D $series^{(R)}$(Japan). The result were as follows: 1. The wider the gap between bone and implant was, the less bone maturity was, and the later osseointegration was occurred. Trabecular direction of new bone around implant was changed from parallel to perpendicular to the implant, and the gap was filled with new bone, over time. 2. There was a decreasing tendency over time in the mobility of all implants, but the wider gap between bone and implant was, the smaller decrease of the mobility was. 3. There was a increasing tendency over time in the removal torque gauge of all implants, and the wider gap was, the smaller increase of the removal torque gauge was. The results suggest that osseointegration in case of implant without primary bone contact may be obtained by guided bone regeneration technique with prolonged healing period, but the time of second surgery should be considered carefully.

  • PDF

Preparation of $PES-TiO_2$ Hybrid Membranes and Evaluation of Membrane Properties ($PES-TiO_2$ 복합막의 제조 및 막 특성 평가)

  • Youm, Kyung-Ho;Lee, Mi-Sheon
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.219-232
    • /
    • 2007
  • The polyethersulfone(PES)-titanium oxide($TiO_2$) hybrid membranes were prepared by immersion precipitation phase inversion method. The casting solution for the preparation of $PES-TiO_2$ hybrid membrane was provided by adding $TiO_2$ nano particles into the basis polymer solution of 14 wt% and 20 wt% PES/N-methyl-2-pyrrolidone(NMP). The $TiO_2$ loading [wt% ($TiO_2/NMP$)] in eating solution was varied from 0 to 60 wt%. Membrane performance and morphological change of the resulting $PES-TiO_2$ hybrid membranes were discussed in aspect of $TiO_2$ loading, by viscosity, coagulation value and light transmittance of the casting solution, measurement of tensile strength, pore size and contact angle, surface and cross sectional SEM images of the hybrid membrane, and ultrafiltration experiments using the hybrid membrane. According as increase of $TiO_2$ loading in the casting solution, viscosity is increased and coagulation value becomes lower, therefore the thermodynamic instability of the casting solution is increased. It is found that when $TiO_2$ loading is increased, 1) precipitation rate becomes faster while instantaneous demixing is maintained, 2) pure water flux, membrane pore size and compaction stability of the resulting membranes are increased, 3) tensile strength and contact angle are decreased. Dead-end ultrafiltration of bovine serum albumin(BSA) solution using the hybrid membrane shows that membrane performance(flux of BSA solution) enhanced up to 7 times compared with the results obtained using the pure PES membrane(not containing $TiO_2$ particle), due to the increase of hydrophilicity.

Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant (표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트)

  • Woo, Jung-A;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.

Preparation and characterization of Ga-doped TiO2 nanofibers by electrospinning (전기방사를 이용한 Ga이 첨가된 나노섬유의 제작 및 특성평가)

  • Song, Chan-Geun;Kang, Won Ho;Yoon, Jong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.6
    • /
    • pp.274-278
    • /
    • 2012
  • $TiO_2$ can be used optically and is applied on many areas such as gas sensor, solar cell and photocatalysis. Electrospun nanofibers have received great interest for development and utilization in some novel applications, such as chemical sensors, dye-sensitized solar cell and photo catalysis. In this study, pure $TiO_2$ and Ga-doped $TiO_2$ nanofibers synthesized by a modified electrospinning method. The Ga doped $TiO_2$ solution is prepared by mixing poly vinyl pyrrolidone, ethyl alcohol, and titanium (IV) isopropoxide. By electrospinning these sols, nanofibers were fabricated. These fibers are heat-treated at $800^{\circ}C$ in air. The prepared pure $TiO_2$ and Ga-doped $TiO_2$ nanofibers samples were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy.

Preparation and Electrochemical Characterization of ZrO2/Ti Electrode by ESD Coating Method (ESD 코팅법에 의한 ZrO2/Ti 전극의 제조 및 전기화학적 특성)

  • Kim, Han-Joo;Hong, Kyeong-Mi;Sung, Bo-Kyung;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.2
    • /
    • pp.95-99
    • /
    • 2008
  • This study has made the electrode that is coated zirconium oxide on the titanium by ESD(Electrostatic spray deposition) coating methode. It has investigated the effects of the etching method of a Ti substrate as the preparation, making of zirconium oxide film and electrochemical characteristics of the electrode that is etched on the titanium. The HCl etching develops a fine and homogeneous roughness on the Ti substrate. Fabrication and material properties of the metal oxide electrode, which is known to be so effective to generate ozone and hypochlorous acid (HOCl) as power oxidant, were studied. A proper metal oxide material is focus zirconium oxide through reference. A coating method to enhance the fabrication reproducibility of the zirconium oxide electrode was used ESD coating method by zirconium oxychloride. Zirconium oxide films on the Ti substrate were tested using SEM, XRD, Cyclic voltammetry.

Effects of phase changes on mechanical properties of Ti-Nb alloys (Ti-Nb계 합금의 상변화가 기계적 성질에 미치는 영향)

  • Park, Hyo-Byeong
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • The use of titanium alloys as biomaterials is increasing due to their superior biocompatibility and enhanced corrosion resistance compared to conventional stainless steels and cobalt-based alloys. Ti-6Al-4V ($\alpha+\beta$type) alloy instead of pure titanium ($\alpha$type) is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. But it has been reported recently that the vanadium element expresses cytotoxicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. In order to overcome their detrimental effects, $\beta$-phase stabilizer Nb was chosen in the present study. This paper was described the influence of phase changes of Ti-Nb alloys on mechanical properties. Ti-3wt.%Nb($\alpha$type),Ti-20wt.%Nb($\alpha+\beta$type) and Ti-40wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. The specimens were homogenized at 1050$^{\circ}C$ for 24hr and were then hot rolled to 50% reduction. Each alloys were solution heat treated at $\beta$ zone and $\alpha+\beta$ zone after homogenization and then were aged. The mechanical properties of Ti alloys were analysed by hardness test, tensile test, elongation test and SEM test. The results can be summarized as follows: 1) The higher hardness value of $\alpha+\beta$type alloy was obtained compared to the, $\alpha,\beta$type alloys. 2) The aged treated showed better hardness compared to the solution heat treated, homogenized. 3) In the case of solution and aging treatment at $\beta$region, the $\alpha+\beta$type alloy showed the most highest tensile strength and $\beta$type alloy showed the best elongation.

  • PDF