• Title/Summary/Keyword: Pupillary distance

Search Result 27, Processing Time 0.022 seconds

The study of reading pupillary distance of the aged population of rural community (농촌지역 노인들의 근용 안경의 동공간거리에 관한 연구)

  • Lee, Il Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.43-47
    • /
    • 2000
  • The purpose of this study is evaluate for effect quality eye care to the aged population of rural community. This study investigated one of important factors in dispensing distance pupillary distance. measured reading pupillary distance, calculated reading pupillary distance into age group and sex. I measured pupillary distance and near inter pupillary distance with corneal reflection pupillometer(shin Nippon PD-82) The objects are male and female living rural community at least 60 years old. The mean pupillary distance for distance of male and female were 63.52 mm, 61.24 mm, respectively. The mean measured reading pupillary distance of male and female were 60.12 mm, 58.08 mm, respectively. Gradient and difference between male and female were same with mean pupillary distance for distance. The result of comparison the mean difference of the mean measured reading pupillary distance and the calculated reading pupillary distance into the age group and sex. This result of changes of addition, as the age is older, the mean addition is greater than youth. I'd like to compare changes of these factors influenced by environmental factors, however I couldn't see about these. So I couldn't considered their relationship and some possible problems of wearing commercial reading glass.

  • PDF

The Examination of Refractive Correction and Heterophoria and Monocular Pupillary Distance on Myopic Elementary School Children Wearing Glasses in Gwangju City (광주지역 근시안경 착용 초등학생의 굴절상태와 사위 및 단안PD에 대한 조사)

  • Hwang, Kwang-Ha;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: This study was designed to investigate the condition of refractive correction and heterophoria and monocular pupillary distance on myopic elementary school children wearing glasses in Gwangju city. Methods: Subjective refraction and objective refraction were examined after investigating heterophoria and monocular pupillary distance on 145 (290eye) elementary school children wearing myopia-corrected glasses. Results: 1. Anisometropia > 2.00 D was present in 4 children (3%). 2. 9 anisometropia (47%) were present in 19 undercorrected visual acuity boy wearers. and 16 anisometropia (64%) were present in 25 undercorrected visual acuity girl wearers. 3. Among the 67 myopic glasses boy wearers, the distance between optical centers was coincided with the pupillary distance in 30% (Oculus Uterque), and discrepant in 70% (Oculus Uterque). Among the 78 myopic glasses girl wearers, the distance between optical centers was coincided with the pupillary distance in 23% (Oculus Uterque), and discrepant in 77% (Oculus Uterque). The mean optical center distance was longer than the pupillary distance on both boy and girl wearers 4. The result of measured heterophoria revealed 14% for orthophoria, 63% for exophoria, 23% for esophoria at far distance and 10% for orthophoria, 76% for exophoria, 14% for esophoria at near distance. Conclusions: Correct refractive test and monocular pupillary distance must be examined because incorrect refractive test and pupillary distance induce asthenopia and heterophoria.

  • PDF

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

A Study for the Reading Pupillary Distance and the Diopters (근용안경의 굴절력과 동공중심간 거리에 대한 연구)

  • Ruck, Do Jin;Shin, Jae Hyun;Park, Kyung Suk;Jun, Young Gi;Sung, Duk Yong;Kang, Sung Soo;Lee, Won Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.57-61
    • /
    • 1999
  • This is a study of measurement of inter Reading Pupillary Distance (P.D.) in 729 old aged farmers (aged over 50). The average of Reading Pupillary Distance (P.D.) in man (58.93mm) is bigger than in woman (57.82mm), and the O.C. of Ready-made Reading Spectacles is 68.98mm.

  • PDF

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

The effect of inter-pupillary distance on stereopsis (동공간 거리가 입체시 지각에 미치는 영향)

  • 감기택;이주환
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2003
  • Most 3D display systems heavily depend on binocular disparity to produce 3-dimensional depth of a scene. In principle, the vergence angle of the object on fixation and binocular disparity of non-fixated objects vary with the inter-pupillary distance(IPD) of the observer. However, most stereo systems provide the identical stereo image pairs regardless of the observers' IPD, which may result in variation in the perceived depth. In this study, we manipulated the vergence angle of the fixated object and binocular disparity of the non-fixated object. The range of the individual difference in the perceived depth was found to be increased with the increase of disparity for both the fixated and non-fixated objects, and the individual difference was well fitted by the regression line of the observers' IPD. These results suggest that individual difference in the perceived depth from the identical stereo images should be greatly reduced if the stereo system calibrates the disparity of the object by the observers' IPD in generating the stereo images and the regression line found in this study might be useful in the calibrating the disparity of the images.

  • PDF

In Watching 3D Stereoscopic Display Using the Binocular Disparity, the Effect of Pupillary Distance of Adults and Children on the Perception of 3D Image (양안시차를 이용한 3D 입체영상 장치의 시청에 있어 성인 및 아동의 동공간거리가 미치는 영향)

  • Kang, Seok Hyon;Hong, HyungKi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.299-305
    • /
    • 2011
  • Purpose: In watching 3D stereoscopic display using the binocular disparity, effect of difference of the pupillary distance between the adults and children on the perception of depth were investigated. Methods: The average PD of children was determined from the PD measurements of children of the elementary school of 2nd and 3rd grade in Seoul. The location of crossing visual axes were derived from the relation of the binocular disparity and the PD for the adults and children. Results: The average PD of the children was measured to be 57.3 mm which was smaller than the average PD of the adults that was known to be about 65 mm. As the binocular disparity increases to the positive direction, the crossing location steeply moves farther behind the screen. On the other hand, when the binocular disparity increases to the negative direction, the crossing location gradually moves toward the viewer. For the same amount of the binocular disparity, the crossing locations were derived to be larger for the children than the adults due to the difference of the PD. Therefore, children will perceive larger depth than the adults. Conclusions: Small PD of the viewer causes the larger amount of the depth perception. In producing the stereoscopic images, the average PD of children as well as adults need to be considered.

The Study of the Abnormal Refraction Eye on the Women Middle and High school Students (여자 중·고등학생들의 굴절이상 눈에 대한 연구)

  • Kim, Douk-Hoon;Shin, Jang-Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.135-140
    • /
    • 1999
  • To investigate the visual acuity of the women middle and high school students, the visual acuity test was performed the object and subject methods. The results were as follows; 1. The eye types were 96.7% positive for myopia, 2.5% for emmetropia, and 0.8% for hyperopia, respectively. 2. The abnormal refraction eyes were 61% positive for simple myopia, 35.2% for myopitic compound astigmatism, 3% for myopic simple astigmatism, and 0.8% for simple presbyopia, respectively. 3. The asix of astigmatism were 95% positive for irregular astigmatism axis, 3% for regular astigmatism axis, and 2% for oblique astigmatism axis, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF

A Study on the Ametropia in Asian Population (아시아 동양인들의 비정시에 관한 연구)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2008
  • Purpose: This study was to investigate the refractive state of an asian population (male: 39, female: 53) from 21 to 30 years old who visited the A optical shop at jongnogu in seoul. Methods: The visual acuity test was performed by the object and subject method. Results: Among the 184 eyes, myopia is 83.16% and emmetropia is 16.84%, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -m0.5Dt < spheric equivalent ${\leq}$ -2.00Dt was 40.53%, the -2.00Dt < spheric equivalent ${\leq}$ -6.00Dt was 51.63% and anything over the -6.00Dt was 7.85%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 46.67%, 35.56% and 7.77%, respectively. The average of pupillary distance in male (64.5${\pm}$2.9 mm) was greater than that in female (61.9${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription by this research.

  • PDF