• Title/Summary/Keyword: Pumping power

Search Result 359, Processing Time 0.023 seconds

Waterhammer for the In-Line Intake Pumping Station with Air Chamber (에어챔버가 설치된 인라인 취수펌프장에서 수격현상)

  • Kim, Kyung-Yup;Ahn, Cheoul-Hong;Kim, Bum-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.70-76
    • /
    • 2012
  • Recently, because people are taking a great interest in the water supply system and the related facilities are getting larger, the surge suppression is very important problem. The waterhammer occurs when the pumps are started or stoped for operation or tripped due to the power failure. As the waterhammer problems as a result of the pump power failure were very serious, these situations were carefully investigated. Accordingly, we carried out both numerical simulations and field tests to confirm the safety of Juam intake pumping station in which had the in-line pumps. In this paper, it was reviewed that the water supply system has the reliability on the pressure surge, in case the air chambers were installed at both the inlet and the oulet of the in-line pumping station. From the numerical simulations, we found that negative pressure occurred at the inlet disappeared and high pressure occurred at the outlet reduced due to the air chambers. And these results of numerical simulations verified by the field tests. The field tests carried out in case of normal start, normal stop, one and two of pumps emergency stop. By results of simulations and field tests, we are sure that Juam intake pumping station in which have the air chambers is safe for the waterhammer. In addition, we suggested the operation methods of facilities for safe maintenance of the pumping station.

Optimal Operation Control for Energy Saving in Water Reuse Pumping System (에너지절감을 위한 물 재이용 펌프시스템의 최적운전 제어)

  • Boo, Chang-Jin;Kim, Ho-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2414-2419
    • /
    • 2012
  • This paper presents an optimal operation control method for energy saving in the water reuse pumping system. A predictive horizon switching strategy is proposed to implement an optimal operation control and a linear programming (LP) algorithm is used to solve optimal problems in each time step. Energy costs are calculated for electricity on both TOU in the light, heavy, and maximum load time period and peak charges. The optimal operation in water reuse pumping systems is determined to reduce the TOU and peak costs. The simulation results show a power energy saving for water reuse pumping systems and power stability improvement.

Waterhammer Caused by Startup and Stoppage of a Centrifugal Pump (원심펌프의 시동 및 정지에 따른 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.51-57
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity As the pressure waves are propagating between the pumping station and the distributing reservoir, the pressure inside the pipe drops to the liquid vapor pressure with the pipeline profile, at which time a vapor cavity forms, and finally the column separation occurs. If the pressure in the pipe is less than the atmospheric pressure, the pipe can be collapsed and destroyed after the water columns separated by the vapor cavity rejoin. During the reverse flow, the pressure is so abnormally increased at the pumping station that the accident of flooding may happen due to the failure of system. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations, in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

PRELIMINARY DESIGN AND ECONOMICS CONSIDERATION OF P-NEW-CITY DISTRICT HEATING MAIN PIPES AND PUMPIG STATION (Flowra를 이용한 P신도시 지역난방 주 배관망 및 펌프장 예비 설계 및 경제성 검토)

  • Kim, Jin-Kwon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.127-128
    • /
    • 2010
  • As P-new-city is planned and constructed, district eating utilizing an existing near-by power plant's waste heat is considered as an economic and environment friendly way of providing heating to the new city. Many pipeline diameters and pumping station location and capacity were assumed, investigated and optimized, to satisfy the customers' heat demand considering common district heating pipe-network design and construction practice, and also and construction, pumping station land price and construction and the pumping energy cost during lifetime of DH systems.

  • PDF

Waterhammer for In-line Booster Pump (직결식 펌프의 수격현상)

  • Kim, Sang-Gyun;Lee, Gye-Bok;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.6 s.33
    • /
    • pp.7-14
    • /
    • 2005
  • The waterhammer occur when the pumps are started or stopped for the operation or tripped due to the power failure, and the hydraulic transients take place as a result of the sudden change in velocity. Several times, the field tests of the waterhammer were carried out for Pangyo booster pumping station. Pangyo pumping station was installed with the booster pumps of 6 sets and the in-line pumps of 2 sets. The in-line pumps are additionally needed to the surge suppression device so that the pumping station acquire the safety and reliability for the pressure surge.

Demonstration of system to combat desertification using renewable energy (신재생에너지를 이용한 사막화 방지 시스템 실증 (몽골))

  • Kim, Man-Il;Lee, Seung-Hun;Whang, Jung-Hun;Cho, Woon-Sic;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.73-76
    • /
    • 2009
  • Generally, wind or solar power system is operated as a stand-alone power system, the efficiency of which could be higher by designing wind-solar combined system considering average wind speed and solar radiation of the desert region, Mongolia. This system is designed to generate electricity for power users and pumps the ground water for irrigation using deep well pump. The ground water can be used for farming or forestation where there is no or little irrigation system. In connection with this study, a renewable energy park, Green Eco Energy Park, was developed at about 50km east of Ulaanbaatar. 3 sets of 10kW wind power generator and 70 kW of solar power module were installed there. The electricity generated from the system is used to on-site office building and deep well pump for ground water pumping. A 10kW stand-alone solar pumping system, which has no rechargeable battery system, is installed to pump the ground water with the amount of generated power. The ground water is stored in 3 artificial ponds and then it is used for raising nursery tree and farming. The purpose of this study is to provide a possible energy solution to desert regions where there is no or little power system. The system also supply power to ground water pump, and the water can be used for farming and forestation, which will also be a solution of preventing desertification or spreading of desert area.

  • PDF

Pump Effect by Injected C-band laser in L-band EDFA (L-band EDFA에서 주입된 C-band laser에 의한 펌프 효과)

  • 김익상;김동욱;김창봉
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.484-491
    • /
    • 2004
  • C-band pumping effect appears in L-band EDFA because the absorption in C-band occurs dominant under the condition of such a low average population inversion. In this paper, we show how the C-band pumping effect depends on 980nm pump power, the C-band wavelength, and its input power. The C-band pumping is caused by absorbing C-band injection or backward spontaneous emission power through EDF. If the same small signal condition is given by a C-band pump, the C-band pump of a long wavelength is good for the saturation and noise characteristics of L-band signal. Finally, it is considered that in the aspect of saturation characteristics, C-band compensation is not so much efficient as L-band in Gain-Clamped L-band EDFA having a lossy resonator.

Characteristics of a CW Ti:sapphire Laser in a Folded Geometry (접힌 공진기 형태의 연속 발진 티타늄 사파이어 레이저의 발진 특성)

  • 강영일;차용호;남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.282-287
    • /
    • 1995
  • We have studied the characteristics of a cw Ti:sapphire laser pumped by an Ar-ion laser. Ti:sapphire is one of the most attractive materials for the generation of ultra-short pulses because of its very broad gain bandwidth. We used a 4.1 mm thick, 0.15 wt. % $Ti^{3+}$ -doped, Brewster-angled Ti:sapphire crystal and made a folded cavity to create a strong focusing mode. The folding angle of the cavity was adjusted to $15.4^{\circ}$ to compensate for the astigmatism from the Brewster-angled Ti:sapphire crystal. 5 WAr-ion laser was used as a pumping source. We observed that the Ti:sapphire cw output power was sensitively changed with respect to the condition of the folded cavity. The threshold pumping power was 2 Wand the slope efficiency was 16% when an output coupler of 10% transmission was used. The maximum output power was more than 450 mW at 5 W pumping. mping.

  • PDF

Numerical Research on Suppression of Thermally Induced Wavefront Distortion of Solid-state Laser Based on Neural Network

  • Liu, Hang;He, Ping;Wang, Juntao;Wang, Dan;Shang, Jianli
    • Current Optics and Photonics
    • /
    • v.6 no.5
    • /
    • pp.479-488
    • /
    • 2022
  • To account for the internal thermal effects of solid-state lasers, a method using a back propagation (BP) neural network integrated with a particle swarm optimization (PSO) algorithm is developed, which is a new wavefront distortion correction technique. In particular, by using a slab laser model, a series of fiber pumped sources are employed to form a controlled array to pump the gain medium, allowing the internal temperature field of the gain medium to be designed by altering the power of each pump source. Furthermore, the BP artificial neural network is employed to construct a nonlinear mapping relationship between the power matrix of the pump array and the thermally induced wavefront aberration. Lastly, the suppression of thermally induced wavefront distortion can be achieved by changing the power matrix of the pump array and obtaining the optimal pump light intensity distribution combined using the PSO algorithm. The minimal beam quality β can be obtained by optimally distributing the pumping light. Compared with the method of designing uniform pumping light into the gain medium, the theoretically computed single pass beam quality β value is optimized from 5.34 to 1.28. In this numerical analysis, experiments are conducted to validate the relationship between the thermally generated wavefront and certain pumping light distributions.