• Title/Summary/Keyword: Pumping power

Search Result 359, Processing Time 0.022 seconds

A Comparison of Estimated Groundwater Consumption Using Existing Formulae with Actual Pumped Volumes in the Haean Basin, Korea (양구해안분지에서 기존 농업용수 이용량 산정식에 따른 양수량과 실측 양수량 비교)

  • Ryu, Han-Sun;Jeon, Woo-Hyun;Kwon, Kideok;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • Efficient groundwater management requires accurate information about the water volume used. The pumped volume of groundwater can be indirectly estimated using empirical formulae based on electric power consumption. The purpose of this study is to test the accuracy of this indirect method. The Haean basin in Gangwon is located in a rural area, where majority of the groundwater extracted is used for irrigation. The pumped volume of groundwater indirectly estimated from electricity usage using these empirical formulae was compared with the actual pumped volume determined by conducting experiments on April 29 and May 19, 2017. The field survey collected data on electricity usage, pumped volume, and groundwater levels. Based on this measured data, correlations were calculated between electricity usage and pumping volume, as well as groundwater level and pumping rate. The results show that electricity usage and pumped volume measured for both wells (YHE1 and YHE2) are highly correlated (r=0.99, p<0.001). However, for YHE1, notably, the correlation between the groundwater level and pumping rate was not significant, and only some correlations were identified for these variables for the YHE2 test well. The average error with respect to the estimation of the actual pumped volume from the existing formula (1) and formulae (2) and (3) are +399% and -88%, respectively. To reduce these errors, these formulae need to consider other factors affecting the pumped volume.

A Numerical Study for Optimum Design of Dust Separator Screen Based on Coanda Effect (코안다효과를 이용한 제진기 스크린의 최적설계를 위한 수치적 연구)

  • Yun, Seong-Min;Kim, Yong-Sun;Shin, Hee-Jea;Ko, Sang-Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.177-185
    • /
    • 2018
  • There is a need to study dust separator screens with good drainage efficiency while effectively filtering suspended solids and other contaminants entering the intake pumping station, the drainage pumping station and the mediation pumping station, the cooling water inlet of the power plant, and the like. In this paper, Numerical studies were conducted for the optimal design of the dust separator screen using the Coanda effect. The shape of the dust separator screen is important, such as the right curvature radius $R_1$ at the top of the dust separator screen and the left curvature radius $R_2$ at the top, h is the height difference and shape between the screen and the accelerating plate, and ${\theta}$ is the inclination angle of the screen. A total of 4 shape factors were set and the effects of Coanda and drainage performance of each element were compared and analyzed, the optimum length and size of each shape element were derived by classifying the shape elements into direct and indirect influences. Finally, it was possible to effectively filter foreign matter by narrowing the screen spacing, and the drainage performance was analyzed and optimized through numerical studies of dust separator screen.

Characteristic ependences of High Power Semiconductor Laser on AR Coating (AR Coating에 따른 고출력 반도체 레이저의 특성변화)

  • 오윤경;곽계달
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.11
    • /
    • pp.29-34
    • /
    • 1995
  • Mirror coating is applied to laser facets to improve properties of edge emitting laser diodes. In this experiment, InGaAsP/GaAs high power laser diodes were studied with respect to different degrees of anti-reflective coating. Sputterred $Al_{2}$O$_{3}$ was used as the coating material and the HR coating was kept constant at 90%. Threshold current density, differential quantum efficiency, emission wavelength and the operating current at 500mW were measured for a range of AR coating and compared with theoretically calculated values; that showed good agreements. Precise wavelength control is important for laser diodes for solid state pumping because of small absorption bandwidth. In addition, since these lasers operate under CW condition, a lowest possible operating current for a given power is desired in order to minimize the heat produced. From the results of this experiment, we were able to obtain a optimum range of AR coatings for minimum operating current. The wavelength can be varied up to 4nm within this range.

  • PDF

A Study on Abnormal Noise Reduction of Scroll Compressor (Scroll Compressor의 이상 소음 저감에 관한 연구)

  • Ahn, B.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.28-35
    • /
    • 1999
  • An application of scroll compressor to the residential air conditioning and heat pump markets has generated many reliability problem, especially abnormal noise. Most of these noise problems is due to the check valve and compliance between FS(Fixed Scroll) and OS(Orbiting Scroll). FS and OS are the main parts of scroll compressor and are the main pumping part. But check valve has the role of protection of reverse rotation of OS when power is off. Check valve have several noise problems. Among them, shut down noise and valve movement noise is more than severe than any other problem. In this paper covers with these two noise problem.

  • PDF

Compact green light sources for laser projection display

  • Ko, Do-Kyeong;Jung, Chang-Soo;Yu, Nan-Ei;Yu, Bong-Ahn;Lee, Yeung-Lak;Lee, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1335-1336
    • /
    • 2008
  • A compact diode-pumped microchip(DPM) green light source which consist of pump LD, $Nd:YVO_4$, KTP and a built-in thermoelectric element has been fabricated for laser projection display. The volume of the source is as small as $0.7\;cm^3$ and we obtained the output power of 25mW with the average electric power consumption in pump LD of 304mW which correspond to the electrical-to-optical efficiency of 7.8%. Another approach using quasi phase matching(QPM) technique has been attempted. We obtained the output power of 90mW of green beam with 350mW pumping of a $Nd:YVO_4$ laser with 20-kHz rep. rate and 10-ns pulse duration. Detailed characteristics and issues of the DPM and QPM green light sources will be addressed.

  • PDF

Improved Passive Power Factor Correction Circuits of Electronic Ballasts for fluorescent lamps (형광등용 전자식 안정기에 적합한 수동 역률개선회로의 제안 및 특성 개선에 관한 연구)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2795-2797
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

Effect of Inclined Wall Number on Heat Transfer and Friction in the Smooth Channel (매끈한 사각채널에서 경사 벽면 수가 열전달과 마찰에 미치는 효과)

  • Lee, Myung-Sung;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.66-72
    • /
    • 2014
  • The local heat transfer and pressure drop of developed turbulent flows in the smooth convergent/divergent channels with rectangular and square cross-sectional areas along the axial distance have been investigated experimentally. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000. The channel hydraulic diameter ratios of 0.67 and 1.49 in the rectangular channel with 2 inclined walls and the ratios 0.75 and 1.33 in the square channel with 4 inclined walls are considered. The comparison showed that among the four channels the square divergent channel has the highest thermal performance at the identical mass flow rate, at the identical pumping power, and at the static pressure drop.

Optical Properties of HVPE Grown GaN Substrates (HVPE법으로 성장된 GaN 기판의 광학적 특성)

  • 김선태;문동찬
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.784-789
    • /
    • 1998
  • In this work, the optical properties of freestanding GaN single crystalline substrate grown by hydride vapor phase epitaxy(HVPE) were investigated. The low temperature PL spectrum in freestanding GaN consists of free and bound exciton emissions, and a deep DAP recombination around at 1.8eV. The optically-pumped stimulated emission in freestanding GaN substrate was observed at room temperature. At the maximum power density of 2MW/$\textrm{cm}^2$, the peak energy and FEHM of stimulated emission were 3.318 eV and 8meV, respectively. The excitation power dependence on the integrated emission intensity indicates the threshold pumping power density of 0.4 MW/$\textrm{cm}^2$.

  • PDF

Cooling Geometry Dependent Operation Properties in a Diode End-Pumped Monolithic Yb:YAG Laser

  • Moon, Hee-Jong;Lim, Changhwan
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.593-600
    • /
    • 2016
  • Operation properties, such as output power, beam radius, and crystal temperature rise were investigated in a diode-pumped edge-cooled monolithic Yb:YAG laser with ~ 4 W pumping level. The output power showed saturation behavior because of severe temperature rise and poor spatial overlapping between pump beam and lasing mode. Face cooling geometry by using a sapphire plate was also investigated. No apparent saturation behavior in output power was observed due to the reduced temperature rise, which could be attributed to efficient heat removal through the crystal-sapphire interface.

Vibration Phenomena between Condensate Vertical Pump and Condenser Debris system in Power Plant (발전소 복수기 볼세정계통에 의한 입형펌프 진동과 대책)

  • Kim, Yeon-Whan;Goo, Jae-Rayng;Bae, Yong-Chae;Lee, Hyun;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1020-1025
    • /
    • 2001
  • Vertical canned pumps are usually applied in the power plant to transport fluids that the available suction pressure is low at the condensate system and the circulating-water system. The top of the motor driver is 5.5m above the base and the barrel and drop column extend even further below the ground. While this size and configuration may produce an efficient pumping system, it also introduces several dynamic problems which must be considered in order to obtain a reliable operation. The main problem is that the vibrational mode of the long flexible cantilever structure above the ground exist near the operational characteristics of the condensate debris system. This system's trouble has been showed at 2,086 hp condensate water loading pumps in a nuclear power plant.

  • PDF