• Title/Summary/Keyword: Pumping capacity

Search Result 128, Processing Time 0.032 seconds

Identification of Mud-Pumping Mechanism by SASW Measurements (SASW 실험에 의한 철도 분니현상의 규명)

  • 강태호;조성호;황선근;이성혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.463-470
    • /
    • 1999
  • The railroad transportation system has more advantages over other transportation systems in terms of low cost, safety and mass transportation The development in economy and social environments lead to the increase of the transportation between cities. As a result, the increased capacity of transportation system is required and maintenance of transportation facilities becomes more important, In the railroad system mud-pumping is one of the troubles to cause distortion of rails and progressive disrupture of subgrade. h this study, SASW measurements were performed to investigate stiffness structures at the sites with mud-pumping and without mud-pumping, Comparison of the stiffness structures revealed the mechanism of mud-pumping and provided information to choose measures for the mud-pumping.

  • PDF

Operational Improvement of Small Urban Storm Water Pumping Station (2) - Comparative Study to Reduce the Flooding Problems using Flood Simulation Model (도시 소유역 배수펌프장 운영개선 방안 연구 (2) - 침수범람모의에 의한 침수방지 방안 비교 연구)

  • Gil, Kyung-Ik;Han, Jong-Ok;Kim, Goo-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.110-115
    • /
    • 2006
  • Flooding situation of Sutak basin was simulated and simulation seemed to be consistent with the real flooding situation in terms of high water levels and timings of flooding. The flood simulation model was used to evaluate alternatives to mitigate flooding problems in Sutak basin. From the evaluation of flood mitigation plans, it was found that combined operation of Sutak and Inchang pumping stations through partial diversion of inflow of Sutak pumping station to Inchang pumping station was the most effective one among the suggested mitigation plans. About 500 meter diversion channel will be needed to send 30% of Sutak pumping station inflow to Inchang pumping station. This will reduce overload of Sutak pumping station and the storage capacity of Inchang pumping station will be more efficiently utilized.

A Determination Method of a Rainwater Retention-Pumping System Combination for Runoff Control from Building Roof Area (지붕면 유출제어를 위한 빗물의 저장-펌프 시스템 조합 결정방안)

  • Kim, Young-Jin;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.495-499
    • /
    • 2008
  • This study developed a determination method for a rainwater retention-pumping combination system for roof runoff control. The outflow and stored water volume in the rainwater system was simulated using a water balance equation. Its result is presented in the TPP (Tank capcity-Peak outflow-Pumping rate) curves for rainfall return periods. In a case study on reduction of the peak flow rate of 100-year return period to 5-year in Seoul, The range of pumping rate for $100m^2$ roof area is determined as $0{\sim}25{\ell}$/min. Additionally, retention volume of $8.5{\sim}10m^3$ can be combined with the pumping rate range. That is to say an effective combination of a retention-pumping system capacity can be determined from a system of $8.5m^3$ tank with $25{\ell}$/min to $10m^3$ tank without pump. Using the TPP curves, engineers can determine the effective combination range of retention & pumping system capacity. Furthermore, that can be helpful to decide a detail system capacity for field condition.

  • PDF

PRELIMINARY DESIGN AND ECONOMICS CONSIDERATION OF P-NEW-CITY DISTRICT HEATING MAIN PIPES AND PUMPIG STATION (Flowra를 이용한 P신도시 지역난방 주 배관망 및 펌프장 예비 설계 및 경제성 검토)

  • Kim, Jin-Kwon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.127-128
    • /
    • 2010
  • As P-new-city is planned and constructed, district eating utilizing an existing near-by power plant's waste heat is considered as an economic and environment friendly way of providing heating to the new city. Many pipeline diameters and pumping station location and capacity were assumed, investigated and optimized, to satisfy the customers' heat demand considering common district heating pipe-network design and construction practice, and also and construction, pumping station land price and construction and the pumping energy cost during lifetime of DH systems.

  • PDF

A Study on Dynamic Analysis of Nano Fountain Pen (나노 파운틴펜의 동적해석에 관한 연구)

  • Lee, Young-Kwan;Kim, Hun-Mo;Kim, Youn-Jae;Lee, Suk-Han
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.922-929
    • /
    • 2006
  • In this study, flow characteristics of the FPN (Fountain Pen Nano-Lithography) using active membrane pumping are investigated. This FPN has integrated chamber, micro channel, and high capacity reservoir for continuous ink feed. The most important aspect in this probe provided control of fluid injection using active membrane pumping in chamber. The flow rates in channel by capillary force are theoretically analyzed, including the control of mass flow rates by deflection of membrane. The above results are compared with numerical simulations that calculated by commercial code, FLUENT. The velocity of fluid in micro channel shows linear behaviors. And the mass flows are proportional to the second order function of pumping pressure that is imposed to membrane.

  • PDF

Statistical Analysis of Aquifer Characteristics Using Pumping Test Data of National Groundwater Monitoring Wells for Korea (국가지하수 관측망의 양수시험 자료를 이용한 국내 대수층 특성의 통계적 분석)

  • Jeon Seon-Keum;Koo Min-HO;Kim Yongje;Kang In-Oak
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.32-44
    • /
    • 2005
  • 314 pumping test data of the National Groundwater Monitoring Wells (NGMWs) are analyzed to present statistical properties of fractured-rock and alluvial aquifers of Korea such as distribution of hydraulic conductivity, empirical relations between transmissivity and specific capacity, and time-drawdown patterns of pumping and recovery test. The mean hydraulic conductivity of alluvial aquifers (1.26 m/day) is 17 times greater than that of fractured-rock aquifers (0.076 m/day). Hydraulic conductivity of fracture-rock aquifers ranges in value over 4 orders of magnitude which coincide with representative values of fractured crystalline rocks and shows distinctive differences among rock types with the lowest values for metamorphic rocks and the highest values for sedimentary rocks. In consideration of the estimated transmissivity with some simplifying assumptions, it Is likely that $32\%$ of groundwater flow for NGMWs would occur through fractured-rock aquifers and $68\%$ through alluvial aquifers. Based on 314 pairs of data, empirical relations between transmissivity and specific capacity are presented for both fractured-rock and alluvial aquifers. Depending on time-drawdown patterns during pumping and recovery test, NGMWs are classified into $4\~5$ types. Most of NCMWs $(83.7\%)$ exhibit the recharge boundary type, which call be attributed to sources of water supply such as streams adjacent to the pumping well, the vertical groundwater flux between fractured-rock and the alluvial aquifers, and the delayed yield associated with gravity drainage occurring in unconfined aquifers.

Study on the aquifer utilization for a ground water heat pump system (지하수 히트펌프 시스템의 대수층 활용 사레 연구)

  • Shim, Byoung-Ohan;Lee, Chul-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

A Study on Flow Characteristics of Fountain-pen Nano-Lithography with Active Membrane Pumping (능동적 박막 펌핑에 의한 파운틴 펜 나노 리소그래피 유동 특성에 관한 연구)

  • Lee Jin-Hyoung;Lee Young-Kwan;Lee Sung-Kun;Lee Suk-Han;Kim Youn-Jea;Kim Hun-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.722-730
    • /
    • 2006
  • In this study, the flow characteristics of a FPN (Fountain Pen Nano-Lithography) using active membrane pumping are investigated. The FPN has integrated chamber, micro channel, and high capacity reservoir for continuous ink feed. The most important aspect in this probe provided control of fluid injection using active membrane pumping in chamber. The flow rates in channel by capillary force are theoretically analyzed, including the control of the mass flow rates by the deflection of the membrane. The above results are compared with the numerical simulations that calculated by commercial code, FLUENT. The velocity of the fluid in micro channel shows linear behaviors. And the mass flows are proportional to the second order function of the pumping pressure that is imposed to the membrane.

Evaluation of Performance of the Railroad Roadbed Material by Model Fatigue lest (실내 모형반복실험에 의한 철도노반재료의 성능 평가)

  • 황선근;이성혁;이시한;최찬용
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.191-198
    • /
    • 2000
  • Dynamic fatigue test is carried out using soil model box for the evaluation of performance of three different roadbed materials. Bearing capacity, settlement and mud pumping phenomenon of each roadbed materials as well as penetration of model ballast into the roadbeds are investigated. It was found that settlement of slag and crushed stone roadbed is smaller than the soil roadbed during dynamic fatigue test with same initial conditions.

  • PDF

A Comparison study on the Performance of Several Types of Air Lubricated Hydrodynamic Thrust Bearings (여러 가지 형식의 동압 공기 윤활 스러스트 베어링의 성능에 대한 비교 연구)

  • 강지훈;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.197-203
    • /
    • 2001
  • In this paper, numerical analyses were undertaken to calculate the static and dynamic performances of step-pocket, inward pumping spiral grooved, outward pumping spiral grooved and herringbone grooved bearings. For each bearing, optimal values for various design parameters were obtained to maximize the load capacity and the stiffness and bearing performances were calculated. The optimized performances of these bearings were compared to conclude that the performance of step-pocket bearing is better than the other bearings.

  • PDF