• 제목/요약/키워드: Pump tower

검색결과 36건 처리시간 0.03초

밀폐식 냉각탑용 열교환기의 성능에 관한 연구 (A Study on the Performance of Heat Exchanger for Closed Cooling Tower)

  • 이상식;유성연;김진혁;안영환;박형준;유해성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

Brief description of the Design and Construction of the Burj Dubai Project, Dubai, UAE.

  • Abdelrazaq Ahmad K.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.9-14
    • /
    • 2005
  • The Burj Dubai Project will be the tallest structure ever built by man; when completed the tower will be more than 700 meter tall and more than 160 floors. The early integration of aerodynamic shaping and wind engineering considerations played a major role in the architectural massing and design of this residential tower, where mitigating and taming the dynamic wind effects was one of the most important design criteria. This paper presents a brief overview of the structural system development and considerations of the tower and discusses the construction planning of the key structural components of the tower.

  • PDF

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.26-31
    • /
    • 2002
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of High Vibration of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.197-202
    • /
    • 2001
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbed the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often get troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-weight balanced representatively or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly that the impeller is installed in the shaft. After clearing the trouble, the high vibration is released and the pump is operated with smooth. In this paper the trouble solution of secondary cooling pump is described including the reason of high vibration.

  • PDF

멤브레인형 LNG선박의 리퀴드 돔 체어 구조개발 (On the New Design of Liquid Dome Chair in Membrane Type LNG Carrier)

  • 김정환;김유일
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.361-367
    • /
    • 2017
  • A membrane type LNG cargo tank is equipped with a pump tower and a liquid dome for loading and unloading of LNG. However, the membrane running continuously on the tank wall to prevent leakage of LNG is interrupted by the liquid dome, hence care should be taken in the design of liquid dome and its substructures. In case of GTT NO96 membrane type cargo containment system, chair structure is arranged along the periphery of the liquid dome targeting to support the membrane which is exposed to the both hull girder and thermal load. This paper proposes a new and simple chair structure, which outperforms traditional design from productivity point of view maintaining same level of structural safety. Strength assessment on the new design was performed to guarantee the structural safety of the new design, which includes strength, fatigue and crack propagation analysis.

LNG 운반선의 구형 화물창 슬로싱 해석 (Sloshing Load Analysis in Spherical Tank of LNG Carrier)

  • 노병재
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2005년도 특별논문집
    • /
    • pp.22-30
    • /
    • 2005
  • Sloshing loads, produced by the violent liquid free-surface motions inside the cargo tank have become an important design parameter in ship building industry since there have been demands for the increased sizes of the cargo containment system of LNG carriers. In this study, sloshing impact pressure acting on the shell of the spherical cargo tank of an LNG carrier as well as dynamic pressure and flow behavior around the pump tower located at the center of the tank have been calculated. Comparative numerical sloshing simulations for a spherical LNG tank using 2-D LR.FLUIDS which is based on the finite difference method and 3-D MSC.DYTRAN which is capable of calculating nonlinear fluid-structure interaction have been carried out. A method of calculating sloshing-induced dynamic loads and the subsequent structural strength analysis for pump tower of a spherical LNG carrier using MSC. DYTRAN and MSC.NASTRAN have been presented.

  • PDF

냉각탑 병용 하이브리드 지열 히트펌프 시스템의 성능 분석 (Performance Analysis of Cooling Tower-Assisted Hybrid Ground-Coupled Heat Pump (HGCHP) System)

  • 손병후;이두영;최재호;민경천
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.19-26
    • /
    • 2016
  • 하이브리드 지열 히트펌프 시스템은 열원을 안정적으로 유지하기 위해 보조 히트싱크나 보조 열원을 활용한다. 본 연구에서는 병원 건물에 설치한 지열-냉각탑 하이브리드 시스템의 냉난방 성능을 분석하였다. 시스템에 각종 센서와 계측 장비를 설치하였으며, 2014년 2월부터 2015년 2월까지 측정한 데이터를 이용하여 성능을 분석하였다. 냉방 기간 중, 냉수 공급 온도는 평균 $11.7^{\circ}C$이었으며, 설계 온도인 $12^{\circ}C$를 넘지 않았다. 또한 난방 기간 중에는 일평균 $39^{\circ}C{\sim}40^{\circ}C$의 온수를 공급하였다. 지열 히트펌프만의 월 평균 성능지수는 3.8에서 8.4의 범위에서 변하였다. 반면 냉각탑을 포함한 하이브리드 지열시스템의 월 평균 성능지수는 2.6에서 6.6 사이에서 변하였다.

두 대의 펌프가 병렬로 설치된 장치의 유량 특성 (FLOW CHARACTERISTICS OF A SYSTEM WHICH HAS TWO PARALLEL PUMPS)

  • 박정근;박종호;박용철
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.1-8
    • /
    • 2012
  • During a reactor normal operation, two parallel 50% capacity cooling pumps circulate primary coolant to remove the fission reaction heat of the reactor through heat exchangers cold by a cooling tower. When one pump is failure, the other pump shall continuously circulate the coolant to remove the residual heat generated by the fuels loaded in the reactor after reactor shutdown. It is necessary to estimate how much flow rate will be supplied to remove the residual heat. We carried out a flow network analysis for the parallel primary pumps based on the piping network of the primary cooling system in HANARO. As result, it is estimated that the flow rate of one pump increased about 1.33 times the rated flow of one pump and was maintained within the limit of the cavitation critical flow.

트랙터부착형 타워집재기 개발(I) - 설계 및 제작- (Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture -)

  • 박상준;김보균
    • 한국산림과학회지
    • /
    • 제97권1호
    • /
    • pp.61-70
    • /
    • 2008
  • 본 연구는 급경사 지형과 간벌사업, 소규모 목재생산 등에 효율적인 가선계 집재기계인 트랙터 부착형 타워집재기를 개발하고자 수행하였다. 타워집재기의 유압동력원은 트랙터의 PTO를 이용한 3개의 유압펌프를 장착하여 4개의 드럼 구동용 모터와 인터록크용 클러치 실린더, 타워신장용 실린더, 아웃트리거 실린더를 작동시킬 수 있도록 설계 제작하였으며, 런닝스카이라인 삭장방식과 인터록크 기능을 채택하고 더블캡스턴드럼과 와이어로프 저장드럼, 인터록크 클러치를 장착한 타워집재기를 개발하였다. 또한 더블캡스턴 드럼의 윈치 구동력 및 견인력과 가선의 이송속도를 산출하여 윈치 구동력은 $191kg{\cdot}m$, 윈치 견인력은 1,910kgf, 더블캡스턴 드럼의 회전수는 220.5rpm, 가선의 이송속도는 138.5m/min의 타워집재기를 개발하였다. 메인라인 250m와 홀백라인 450m을 저장하기 위해서는 메인라인 및 홀백라인 저장드럼의 플랜지 직경은 각각 약 360mm와 약 460mm가 최적이라는 것을 알 수 있었다. 런닝스카이라인 삭장방식에 맞고 쵸킹작업이 용이하고 집재목의 처짐을 방지하기 위한 잠금장치를 장착한 반송기를 개발하였으며, 타워집재기의 인터록크 기능을 고려하고 조작의 수월성과 작업의 효율성을 위한 유선 리모트 콘트롤러를 개발하였다. 타워집재기의 견인 및 이동을 위해 트랙터의 후방 3점 히치 연결장치와 고무바퀴를 장착하였으며, 타워집재기의 안전성과 작업의 효율성을 높이기 위해 아우트리거와 버팀줄을 장착한 타워집재기를 개발하였다.

LNG-FPSO 선박 장비들의 보전활동 지원시스템 개발에 관한 연구 (A Study on the Development of Maintenance System for Equipment of LNG-FPSO Ship)

  • 이순섭;강동훈;이종현;이승준
    • 해양환경안전학회지
    • /
    • 제22권2호
    • /
    • pp.233-239
    • /
    • 2016
  • 본 연구에서는 LNG-FPSO 선박에 탑재되어 있는 장비들의 운영효율을 최대화하기 위한 상태기반유지보수(CBM) 활동을 지원하는 보전시스템을 개발하였다. 개발된 보전시스템에서는 상태기반유지보수를 수행할 주요 장비들을 식별하여 이를 PWBS(Product Work Breakdown Structure)로 정의하였고 식별된 장비들로부터 실시간 수집되는 센서데이터를 이용하여 장비들의 고장분석과 최적 유지 보수 방안을 결정하기 위한 경제성평가 등을 수행하며, 이들을 수행하기 위해 필요한 입출력 데이터를 저장, 관리하는 고장사례 및 유지보수데이터베이스를 구축하였다. 개발시스템의 성능검증을 현재 개발 중인 LNG-FPSO 선박의 Inlet 시스템의 Compressor와 화물창의 Pump Tower 등과 같은 주요 장비들을 대상으로 실시하였고 이를 바탕으로 상태기반유지보수의 가능성을 확인하였다.