• Title/Summary/Keyword: Pump performances

Search Result 145, Processing Time 0.025 seconds

Performance improvement of BOP Components for 1kW Stationary Fuel Cell Systems to Promote Green-Home Dissemination Project (그린홈 보급확대를 위한 건물용 연료전지 보조기기의 성능 향상)

  • Lee, Sunho;Kim, Dongha;Kim, Minseok;Jun, Heekwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • According to green growth's policy, green-home dissemination's projects are promoting. Among them, stationary fuel cell systems are receiving attention due to high efficiency and clear energy. But it need absolutely to develop cost down technologies and improve system durability for commercialization of the fuel cell system. To achieve this objectives, in 2009, the Korean Government and "Korea Institute of Energy Technology Evaluation and Planning(KETEP)" launched into the strategic development project of BOP technology for practical applications and commercializations of stationary fuel cell systems, named "Technology Development on Cost Reduction of BOP Components for 1kW Stationary Fuel Cell Systems to Promote Green-Home Dissemination Project". This paper introduces a summary of improved BOP performances that has been achieved through the 2nd year development precesses(2010.06~2011.05) base on 1st year development precesses(2009.06~2010.05). The major elements for fuel cell systems are cathode air blowers, burner air blowers, preferential oxidation air blowers, fuel blowers, cooling water pumps, reformer water pumps, heat recovery pumps, mass flow meters, electrical valves, safety valves and a low-voltage inverter. Key targets of those elements are the reduction of cost, power consumption and noise. Invert's key targets are development the low -voltage technologies in order to reduce the number of unit cell in fuel cell system's stack.

  • PDF

Performance Test of a 75-tonf Rocket Engine Turbopump (75톤급 액체로켓엔진용 터보펌프 실매질 성능시험)

  • Jeong, Eunhwan;Kwak, Hyun-Duck;Kim, Dae-Jin;Kim, Jin-Sun;Noh, Jun-Gu;Park, Min-Ju;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Wang, Seong-Won;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Woo, Seong-Phil;Han, Yeong-Min;Kim, Jinhan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.86-93
    • /
    • 2016
  • Performance tests of a 75-tonf liquid rocket engine turbopump were conducted. The performance of sub-components - two pumps and a turbine - and their power matching were measured and examined firstly near the design speed under the LN2 and kerosene environment. In the real propellant - LOX and kerosene - environment tests, design and off-design performance of turbopump were fully verified in regime of the rocket engine operation. During the off-design performance tests, turbopump running time was set longer than the engine operating time to verify the pump operability and set the pump inlet pressure close to design NPSHr to investigate pump suction capability in parallel. It has been found that developed-turbopump satisfied all of the engine required performances.

Development of the Automatic Fishing System for the Anchovy Scoop nets (I) - The hydraulic winder device for the boom control - (멸치초망 어업의 조업자동화 시스템 개발 (I) -챗대 조작용 유압 권양기 개발-)

  • 박성욱;배봉성;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.166-174
    • /
    • 2000
  • Anchovy, EngrauEis japonica scoop nets are used in the coastal of Southern and Cheju of Korea. Especially in the Cheju, the fishing gear of scoop nets consists of upper boom, lower boom, pressing stick and bag net. They are operated by fishing boats of 6 to 10 ton class and 8 persons on board. The booms are controlled by side drum, and the net and pressing stick are hauled by only human power in operating. Therefore this fishery needs to large labor and heavy human power and has much risk. Three kinds of hydraulic winding device which controls two booms was designed and manufactured to reduce heavy labor force of scoop nets, and trial in the sea was carried out to test their performances using the commercial fishing boats of 6 ton class. The proper capacity of hydraulic pump and motor were determined by model test of boom 1/5 scale. The results obtained are as follows, 1. Tension of boom which is being drawn was the strongest and 187.5kgf when the boom's end is in the depth of 4m under the water. 2. The hydraulic motor of the fittest kind of winder has the least leakage per time than the other kinds. 3. In the best type of several winder devices, when the pressure difference was fixed $130kg/^2$ for the safe fishery, the winding velocity of boom line was 2m/sec, is faster 0.48/sec than traditional fishing method and this winder can catch the anchovy of 1.6 tonnage. 4. As a result, the crew were decreased from 8 to 6 and the problem of heavy human power and risk on fishing operation were solved by using the this winder.

  • PDF

Performance Analysis of Intake Screens in Power Plants on Mass Impingement of Marine Organisms (발전소 취수구에 대량으로 유입하는 해양생물에 대한 스크린 설비의 성능분석)

  • Lee, Jae-Hac;Choi, Hyun-Woo;Chae, Jin-Ho;Kim, Dong-Sung;Lee, Seung-Baek
    • Ocean and Polar Research
    • /
    • v.28 no.4
    • /
    • pp.385-393
    • /
    • 2006
  • Screening performance of the existing intake screens (drum and travelling screen) on mass impingement of marine animals, a euphausiid, Euphausia pacifica and a scyphozoan medusae, Aurelia aurita that have often clogged intake screens of the Uljin Nuclear Power Plant, was tested. The maximum tolerable densities of marine animals in the inflowing seawater upon the screen were estimated with two different approaches. First the maximum density of jellyfish was calculated from (1) passing amount of seawater per unit time through the screens and (2) the covered area of animals on the screens clogged. The maximum density of krill tolerable in the drum screen was cited from a simulated record of Uljin NPP, then those in the travelling screens were also calculated using the data of drum screen and ratio of seawater amount passing through the screens under the condition of 0.5m water column (W.C.) of the differential pressure (AP) produced by screens, an established permissible limit of ${\Delta}P$. Secondly, the screening performances were also tested by hydrodynamic measurements with various screen models in a circulating water channel equipped with a speed-controlling pump and a differential pressure gauge. From the first approach, the maximum tolerable densities of drum and travelling screen were calculated as 2.0 and $1.5ind/m^3$ for the Jellyfish and 900 and $680ind./m^3$ for the euphausiid, respectively. These densities estimated from the second approach were 2.1 and $0.8ind/m^3$ for the jellyfish and 1059 and $504ind/m^3$ for the euphausiid, respectively. These estimates were compared with the data from historic clogging events to evaluate the practical performance of these intake screens. The comparisons suggest a newly improved intake-screen of which performance should be at least seven times (approximately) better than the existing ones ior the krill and 3.2 times for the jellyfish, respectively, for preventing mass impingement, and for maintaining the condition of the differential pressure between the screens below 0.3 m W.C.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF