• 제목/요약/키워드: Pump Selection

검색결과 77건 처리시간 0.031초

원심펌프 벌류트 혀의 균열 원인분석 및 건전성 평가 (Integrity Evaluation and Root Cause Analysis of Cracks at the Volute Tongue of Centrifugal Pump)

  • 박치용;김진원;김양석
    • 한국유체기계학회 논문집
    • /
    • 제3권4호
    • /
    • pp.7-14
    • /
    • 2000
  • This paper provides integrity evaluation and root cause analysis for defects observed at volute tongue, or cutwater, of the operating centrifugal pump in power plant. The cause of the cracks are analyzed and reviewed from the viewpoint of the operation and maintenance of the pumps, and the sample obtained from the cracked volute tongue of the pump are examined. At first, in-situ hardness test and microstructure examination were performed to understand the cause of cracking at volute tongue. The evaluation of structural integrity and the possibility of the crack propagation is also evaluated. Cracks were typical intergranular cracking and propagated along with prior austenite grain boundary. At easing volute tongue, the hardness was higher than ASTM requirement and a large amount of intergranular Cr carbide was precipitated. These were due to high C content in material. P content was also higher than ASTM requirement. Therefore, Cr carbide precipitation and P segregation at grain boundary, caused by higher C and P content in material, resulted in intergranular cracking of casing volute tongue. This procedure for integrity evaluation and root cause analysis is used to guide, and support the pump designer and manufacturer's material selection and process design to avoid a costly, unplanned outage of plant.

  • PDF

지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가 (A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump)

  • 정영주;조재훈;김용식;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.

반도체 광 증폭기내에서의 4광파 혼합을 이용한 2.5Gb/s 광신호의 전광 파장변환 (All-optical wavelength conversion of 2.5 Gb/s optical signals by four-wave mixing in a semiconductor optical amplifier)

  • 방준학;서완석;이성은
    • 전자공학회논문지D
    • /
    • 제35D권8호
    • /
    • pp.69-75
    • /
    • 1998
  • We demonstrate wavelength conversion of 2.5Gb/s optical signals by four-wave mixing (FWM) in a semiconductor optical amplifier (SOA). We investigate the effect of input pump and signal powers on the coversion efficiency, optical signal-to-noise ratio (OSNR) and extinction ratio to be a measure of performance in a wavelength converter. As a result, we show that the maximum bit error rate (BER) performance can be obtained by co promising among high-vonversion efficiency (minimum Pprobe), high-OSNR (maximum Pprobe) and low-cross-gain saturation effects (Pprobe kept at least 6dB weaker than Ppump). In our experiment, we obtain optimum performance at +3 dBm pump power and -6dBm signal power. The power penalty incurred in the wavelength conversion can be minimized by careful selection of the input pump and signal powers. We show that about 0.5dB power penalty for 3.2nm wavelength coversion at 10-10 BER is achievable.

  • PDF

역설계 방법을 적용한 사류펌프의 임펠러 및 디퓨저 설계 (Design of Impeller and Diffuser for Mixed Flow Pump with Inverse Design Method)

  • 이경용;최영석;김준호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1322-1325
    • /
    • 2009
  • The impeller and vane diffuser for the mixed flow pump(NS550) was designed by using meridional selection program and inverse design method. We decided the meridional shape of the impeller from the meridional design parameter, such as the specific speed and maximum diameter at the impeller exit. The meridional shape of vane diffuser was set from the impeller shape, distribution of cross sectional area and maximum diffuser diameter. The angle of impeller blade and diffuser vane was designed by using inverse design method. The predicted overall performance by using commercial CFD code(ANSYS CFX-11) shown good agreement with design goals.

  • PDF

극저온 잠액식 펌프의 국산화를 위한 융합 기술 개발 (The Development of Convergent Technique for Localization of the Cryogenic Submerged Pump)

  • 황규완;배태용
    • 한국융합학회논문지
    • /
    • 제9권7호
    • /
    • pp.199-203
    • /
    • 2018
  • 온실가스 배출규제에 따라 국내 조선소를 중심으로 LNG연료로 추진되는 친환경 선박기술 도입에 박차를 가하고 있는 실정이다. 그러나, 선박의 LNG 연료공급을 위한 극저온 펌프 (Cryogenic Pump) 제작의 국내 기술력은 매우 미흡한 현실로서 핵심 부품의 설계와 제작기술이 절실한 시점이다. 그리하여, 본 연구는 선박용 LNG 공급시스템용 극저온 잠액식 원심펌프의 핵심부품인 로터에 대하여 기술하고자 한다. 따라서, 재료선정을 위한 실험적 및 해석적 방법을 통한 최적결과를 도출하여 기술개발의 기초자료로 활용하고자 한다.

전기구동 히트펌프(EHP)와 가스엔진구동 히트펌프(GHP)의 에너지소비량 및 환경부하 분석 (Analysis of Energy Consumption & Environmental Load of Electric Heat Pump and Gas Engine Driven Heat Pump)

  • 김상훈;임상채;정광섭;김영일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.933-937
    • /
    • 2006
  • Energy is motive power that makes convenient society. But, our country's energy is depending on most import. Also, energy and environmental issue are important problem in community of nations. The purpose of this study is to analysis the energy consumption and environmental load of EHP and GHP in Medium and small-scaled office building. The annual energy consumption used to cooling and heating by EHP was 10 percent more than GHP. And annual energy cost of EHP was 33 percent more expensive than GHP. But, Compared to the annual $CO_2$ emission, EHP was 6 percent less than GHP. Therefore, equipment selection should be consider environmental load as well as energy consumption and cost.

  • PDF

Simulation of Vacuum Characteristics of High Vacuum System Modelled by VacCAD

  • Kim, Hyungtaek;Park, Junhyung;Yun, Gyeongah
    • International journal of advanced smart convergence
    • /
    • 제7권4호
    • /
    • pp.84-91
    • /
    • 2018
  • In this paper, we simulated three different HV systems and analyzed of each vacuum characteristics by VacCAD modelling. In each of modelled vacuum systems, selection of chamber materials, combination of rough pump with high vacuum pump and conductance of roughing line (diameter and length) were proposed as system variables. In the modelling of chamber materials, the pumping times to ultimate pressures of different chamber materials (stainless steel, aluminum) were compared by the variations of chamber volume. In this model, the effects of outgassing dependent on the chamber materials was also simulated and aluminum was estimated to optimum chamber materials. It was also obtained that modelling of vane and roots pump with diffusion pump and diameter, length of $50{\times}250$ [mm]roughing line were characterized as optimum variables to reach the ultimate pressure of 10E-7 [mbar] most effectively. Optimum design factors for vacuum characteristics of modelled vacuum system were achieved by VacCAD simulations. Feasibility of VacCAD as vacuum simulator was verified and applications of VacCAD expected to be increased to fields in vacuum needed.

Complex ESP Systems Proposal based on Pump Syringe and Electronically injector Modules for Medical Application

  • HAMROUNI, Chafaa
    • Journal of Multimedia Information System
    • /
    • 제7권2호
    • /
    • pp.175-188
    • /
    • 2020
  • The paper focuses on conception and development of complex systems composed mainly by a pump syringe subsystem and an electronically injector that facilitates patients saving data operation for medical staff use. We successfully developed conventional approaches for medical system staff requirements, such as system boundary conditions. Decisions at a given level are studied. We propose a complex system architecture, based mainly on patients collected data and ordered stepper injection parameters. System is successfully simulated and prototyped. Design and implement tests are accomplished, the proposed system ensures both the electric syringe pump and the electric injector operation. In addition, this new system introduces several additional options as patient database development and automation injection operation. Development and software operating tests to create a visualization control interface are validated. The solution performs syringe function and electronic injector. User can manage a syringe in two C modes of technology. We propose a program composed of two linked parts. If an error such radiologist bad target selection is made, an image with lower intrinsic quality emerges. Developed Shoot syringe different electronic cards are simulated and prototyped, in addition, maps are driven, prototype. All tests results are accomplished.

염색폐수를 이용한 고온수 히트펌프 시스템 타당성 연구 (The Study of Validity on the High Temperature Heat Pump System using Dyeing Wastewater)

  • 김정열;정동열;박승상;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.996-1001
    • /
    • 2009
  • The purposes of this work were suggested and validated the methods of heat recovery from dyeing wastewater exhausted in Sihwa and Banwol dyeing industrial park. We analyzed the present conditions of heat supplies and demands. So it was made a selection of the system combined heat exchanger for waste heat recovery and the high temperature heat pump. We decided the specifications of the heat recovery facilities. After this, economical assessment is performed to this system. The payback periods are within 4 years, 20 years and 5 years in case of K company, S company and A company. In addition, when they are produced the heat of same capacity, quantities of pollutants from used fuels were calculated.

  • PDF

Simulation of High Vacuum Characteristics by VacTran Simulator

  • Kim, Hyung-Taek;Jeong, Hyeongwon
    • International journal of advanced smart convergence
    • /
    • 제11권4호
    • /
    • pp.88-95
    • /
    • 2022
  • Vacuum simulation is associated with the prediction and calculation of how materials, pumps and systems will perform using mathematical equations. In this investigation, three different high vacuum systems were simulated and estimated with each vacuum characteristics by VacTran simulator. In each of modelled vacuum systems, selection of gas loads into vessel, combination of rough and high vacuum pumps and dimension of conductance elements were proposed as system variables. In pump station model, the pumping speed to pressures by the combination of root pump was analyzed under the variations of vessel volume. In this study, the effects of outgassing dependent on vessel materials was also simulated and aluminum vessel was estimated to optimum materials. It was obtained from the modelling with diffusion pump that the diameter, length of 50×250[mm]roughing line was characterized as optimum variables to reach the ultimate pressure of 10E-7[torr]. Optimum design factors for vacuum characteristics of modelled vacuum system were achieved by VacTran simulator. Feasibility of VacTran as vacuum simulator was verified and applications of VacTran in high tech process expected to be increased.