• 제목/요약/키워드: Pump Magneto-Hydrodynamics

검색결과 2건 처리시간 0.015초

동작 전류에 의한 Magnetic fluid Linear Pump의 동특성 해석 (Analysis of the Driving Characteristics in the Magnetic Fluid Linear Pump by Operating Current)

  • 서강;박관수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.237-246
    • /
    • 2004
  • The advantages of the Magnetic Fluid Linear Pump(MFLP) is that this device could Pump the non-conductive. non-magnetic liquid such as Insulin or blood because of the segregation structure of the magnetic fluid and pumping liquid. In this device. the sequential currents are needed to Produce pumping forces so that Pumping Forces and Pumping speed mainly depend on the current Patterns. The excessive forces at Pumping moment could cause the medical shock, and weak forces at intermediate moment could cause the back flow or the pumping liquid. So the ripples of the pumping forces need to be reduced for the medical application. In this research, the driving characteristics in the MFLP by operating current is analysed. The change of magnetic fluid surface according to the driving currents could be obtained be magneto-hydrodynamic analysis so that Pumping fortes could be computed by integration of the surface moving to the pumping direction at each moment. The actual MFLP with 13mm diameter was made and tested for experiments. The effects of driving current and frequency on the pumping forces and pumping speed were analyzed and compared with experimental measurements.

Magnetic Fluid Linear Pump의 AC 전류에 의한 운전 특성에 관한 연구 (Study of the Driving Characteristics in the Magnetic Fluid Linear Pump by AC Operating Currents)

  • 박관수;서강
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권3호
    • /
    • pp.111-119
    • /
    • 2005
  • In the magnetic fluid linear pump, the pumping forces and pumping speed mainly depend on the current patterns. In this research, a new design to reduce the discontinuities of the pumping forces of the MFLP was studied. Continuous pumping of the newly designed MFLP by using AC current increases pumping efficiency and reduces the pumping force. Forming shapes of the magnetic fluid at the intermediate state were computed and compared to measurement. Since the back flow of the fluid is reduced remarkably, 4 yoke's AC driving is more efficient than 7 yoke's DC driving. The size, weight and pumping discontinuity are also reduced.