• 제목/요약/키워드: Pump Efficiency

Search Result 1,032, Processing Time 0.026 seconds

Optimal Design of a Gear Pump for Yarning (방사용 기어펌프 최적설계)

  • 천길정
    • Tribology and Lubricants
    • /
    • v.18 no.4
    • /
    • pp.279-284
    • /
    • 2002
  • Optimal design program for an external gear pump for yarning has been developed. Optimization is accomplished using ADS program. Pump design parameters can be determined automatically for maximum gear efficiency with constraints considering shaft, bearing, gear and pump. Comparing the design parameters obtained by the program with those of the sample, it was verified that the program could be used as a design tool if it is modified a little.

Optimal Design of a Gear Pump for Yarning (방사용 기어펌프 최적설계)

  • Cheon, Gill-Jeong;Youn, In-Seong
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.457-463
    • /
    • 2001
  • Optimal design program for an external gear pump for yarning has been developed. Optimization is accomplished using ADS program. Pump design parameters can be determined automatically for maximum gear efficiency with constraints considering shaft, bearing, gear and pump. Comparing the design parameters obtained by the program with those of the sample, it was verified that the program could be used as a design tool if it is modified a little.

  • PDF

Matching Diffuser Vane with Return Vane Installed in Multistage Centrifugal Pump

  • Kawashima, Daisuke;Kanemoto, Toshiaki;Sakoda, Kazuyuki;Wada, Akihiro;Hara, Takashi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.86-91
    • /
    • 2008
  • The effects of the diffuser vane on the performances of the multistage centrifugal pump were investigated experimentally, taking account of the interactions among the diffuser vane, the return vane, and the next stage impeller. It is very important to match well the diffuser vane with the return vane, for improving the hydraulic efficiency of the pump. The efficiency may be more improved by making the cross-sectional area of the channel from the diffuser vane outlet to the return vane inlet larger, as much as possible.

A Study on the Burning Damage of a Driving Motor for Warship Fire Pump (함정용 소화펌프 구동 모터의 소손현상 개선에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1035-1041
    • /
    • 2007
  • An improvement of driving motor burning damages on a couplingless type warship fire pump is studied. The pump consists of an induction motor a pump-motor shaft and a volute type impeller. The burning damage had occured by changing the material of the pump-motor shaft from carbon steel(SM 45C) to stainless steel(STS 316) for improving anti-corrision properity in sea water. It is shown that a material change on the pump-motor shaft can reduce the efficiency of driving motor and may cause motor burning in the process of pump development stage. This kind of motor burning problem can be solved by increasing the efficiency of the motor and changing the geometry of the inner parts.

A Study of Performance Improvement of a Vaporizer Sea-Water Pump (기화해수펌프 성능 개선에 대한 연구)

  • Kim, Yang-Ik;Chung, Kyung-Nam
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.645-649
    • /
    • 2005
  • In this study, redesign of a vaporizer sea-water pump has been carried out using computational fluid dynamics. The flow field of the specified pump model is simulated and analyzed. In the flow analysis full pump model has been used, and multi-block grids are employed to solve the governing equations. In order to improve pump efficiency, systematic redesign has been performed to remove the flow recirculation near the hub of the diffuser vanes. The modified model shows about 4 % improvement in pump efficiency compared to the given model.

  • PDF

Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles (인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가)

  • Kim, Kyungwuk;Suh, Sang-Ho;Rakibuzzaman, Rakibuzzaman
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

로켓엔진용 연료펌프의 성능 시험

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.143-149
    • /
    • 2005
  • To evaluate the hydraulic and cavitation performance of a fuel pump for a liquid rocket engine, performance tests of the pump, which consist of hydraulic tests and cavitation tests, were conducted in water environment with various condition. In the hydraulic tests, the head, efficiency and volute pressure distribution of the pump are found to follow the conventional similarity rule, whereas the secondary flow pressure shows a small deviation from the similarity rule. As the floating gap is constricted, the efficiency of the pump improves and the secondary flow pressure decreases. However, the inner diameter of bypass line orifice does not show clear relationship with the pump efficiency. In the cavitation tests, measurements of the head and the NPSH indicate that the pump shows better cavitation performance as the rotational speed of the pump increases.

  • PDF

Aplication of the Thermodynamic Measurement Method for On-site Performance Evaluation of Hot Water Pumps Used in District Heating (지역난방 중온수 펌프의 현장 성능평가를 위한 열역학적 측정법 적용)

  • Park, Cheol Gyu;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2021
  • It is very difficult to accurately calculate efficiency of each accessory device constituting the pump system and pump efficiency by the Conventional efficiency measurement method only. Therefore, this study introduced the lastest Thermodynamic pump efficiency measurement method in the district heating pump system for the first time in Korea. As a result, data uncertainty was high by the Conventional method, but the pump and Hydraulic Coupling efficiency values applied the Thermodynamic and Conventional method parallel measurement data were able to derive meaningful results that verified the reliability and adequancy of the pump performance measurement method by performing complementary roles. In additon, as a result of applying the Thermodynamic method to the distirct heating pump system, despite the high temperature environment of up to 120 ℃, it was possible to verify the reliability of the Thermodynamic method, such as high stable data mesurement, and durability of the measurement equipment.

Effect of The Impeller Discharge Angle on the Performance of a Spurt Vacuum Pump

  • Lee, Ji-Gu;Kim, Youn-Jea
    • Applied Science and Convergence Technology
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • The spurt vacuum pump is widely used to transfer sludge and slurry, and to control flow rate in a variety of processing fields, such as the oil, chemical, and fiber industries. The efficiency of the pump depends on the design parameters of the impeller, such as the number of blades, and the blade angle. In this study, the effect of the configuration of the impeller discharge angle of a spurt vacuum pump, which influences total head, shaft power, and efficiency, was numerically investigated using the commercial code, ANSYS CFX ver. 16.1. In addition, the performance of the pump was evaluated on the basis of the correlations between the total head, pump efficiency, and pressure distribution.

High-Efficiency Charge Pump for CMOS Image Sensor (CMOS 이미지 센서를 위한 고효율 Charge Pump)

  • Kim, Ju-Ha;Jun, Young-Hyun;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.50-57
    • /
    • 2008
  • In this paper, a high-efficiency charge pump for use in CMOS image sensor(CIS) is proposed. The proposed charge pump pursues high pumping efficiency by minimizing the switching and reversion losses by taking advantage of operation characteristics of CIS. That is, the proposed charge pump minimizes the switching loss by dynamically controlling the size of clock driver, pumping capacitor, and charge transfer switch based on the operation phase of CIS pixel sensor. The charge pump also minimizes the reversion loss by guaranteeing a sufficient non-overlapping period of local clocks using a tri-state local clock driver adapting the schmitt trigger. Comparison results using a 0.13-um CMOS process technology indicate that the proposed charge pump achieves up to 49.1% reduction on power consumption under no loading current condition as compared to conventional charge pump. They also indicate that the charge pump provides 19.0% reduction on power consumption under the maximum loading current condition.