• 제목/요약/키워드: Pump Case

검색결과 523건 처리시간 0.023초

연료분사펌프의 윤활 특성 개선: 제2부 - 그루브의 적용 (Improvement of the Lubrication Characteristics of Fuel Injection Pump for Medium-Speed Diesel Engines: Part II - Application of Grooves)

  • 홍성호;이보라;조용주
    • Tribology and Lubricants
    • /
    • 제31권5호
    • /
    • pp.213-220
    • /
    • 2015
  • This study evaluates the effect of grooves on the stem part of a plunger on the lubrication characteristics of a fuel injection pump (FIP) by using hydrodynamic lubrication analysis. The current study uses the two-dimensional Reynolds equation to evaluate the changes in lubrication characteristics with variations in clearance, viscosity, and grooves for a laminar, incompressible, and unsteady state flow. This study investigates the lubrication characteristics by comparing the dimensionless minimum film thickness or the film parameter, which is the ratio of the minimum film thickness to surface roughness. The analysis method for the groove section differs depending on the depth of the groove. For instance, in the case of a shallow groove, the film thickness equation considers the depth of the groove, while in the case of a deep grove, it considers the flow continuity. The lubrication characteristics of the FIP are more sensitive to changes in the groove width than to changes in other design variables. Moreover, the application of a groove is more effective under low viscosity conditions. The smaller the distance from the edge of the stem part to the first groove in the case of shallow grooves, the better are the lubrication characteristics of the FIP. In contrast, in the case of deep grooves, the lubrication characteristics of the FIP improve as the distance increases. The application of shallow grooves is more effective for improving the lubrication characteristics than the application of deep grooves.

대학교 강의실 EHP 제어를 이용한 에너지 절약 시스템 (Energy Saving System of EHP Control at the College Lecture Room)

  • 정기범
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.167-174
    • /
    • 2014
  • Heating and air conditioning system is changing rapidly from the traditional HVAC central supply system to the individual supply system with electrical heat pump system (EHP) in Korean school buildings. The individual supply system has advantages to turn on and off individually and to adjust the thermal comfort separately, but energy is wasted in the unoccupied classroom when the last leaving occupant does not turn off the controller. If the controller is to be off automatically while the classroom is not in use, energy consumption would decrease dramatically. This project aims to cease the unnecessary EHP supply in vacant classroom by inputting the class schedule from the central control room to reduce the energy-spending. Experimental measurements were carried out between the controlled classroom that is turned off when not in use and the uncontrolled room that is turned on continually. Occupant's comfort and energy consumption were measured and compared between the controlled case and the uncontrolled case. The energy consumption of controlled classroom case is 30-60% less than that of the uncontrolled classroom case. This result shows that controlling the cooling supply for the unoccupied classroom using the class schedule can decrease the energy consumption remarkably. This supply control system can be used to conserve energy in school structures like universities.

자이로용 Er-첨가 광섬유 광원에서 편광 스크램블링을 이용한 편광효과의 억제 (Suppression of polarization effects in Er-doped fiber source for gyroscope by polarization scrambling)

  • 김택중;진영준;박희갑
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.449-453
    • /
    • 2003
  • 자이로스코프용 광대역폭 erbium 첨가 광섬유 광원에서 중심파장의 편광의존성을 억제하기 위하여 펌프광의 편광을 변조함으로써 스크램블링하는 방식을 사용하였다. 원통형 PZT에 광섬유를 감은 형태의 편광변조기에 적정진폭의 변조를 가함으로써 펌프광의 편광도(시간평균치)를 1.4%까지 낮출 수 있었다. 펌프 편광 스크램블러와 출력단 depolarizer를 함께 사용한 경우에 임의의 편광변화에 대한 광원의 중심파장 변화가 측정기의 측정한계(∼5 ppm) 이하로 관찰되었다.

모터 일체형 유압 파워 패키지의 개발 (Development of a Hydraulic Power Package Enclosed with an Electric Motor)

  • 박용호;이창돈;이진걸
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.55-61
    • /
    • 2000
  • In this study, a new design of an one-body type of an unbalanced-fixed- displacement type vane pump combined with an induction type electric motor was suggested. By the application of the new design scheme, it was possible to reduce the number of parts of the pump system and to cut down the volume of power package than that of already-used products. The case in this study enabled efficient heat transfer and electricity insulation of hydraulic fluid. Thus oil moves through the inside of the package for cooling and returns to the reservoir. Because of this design, it was difficult to measure the shaft-input torque. Therefore the package overall efficiency in the paper was evaluated with a ratio of hydraulic power and electric power.

  • PDF

우물관정형(SCW공법) 지열히트펌프 시스템의 설치 및 운영사례 (A Case Study on the Installation and Operation of the Standing Column Well Method)

  • 나상민;박시삼;박종헌;이건중;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.592-595
    • /
    • 2009
  • In recent years, geothermal heat pump (GHP) systems have become increasingly popular for heating and cooling in buildings. The Standing Column Well (SCW) method is one of the most efficient GHP system. Because it use groundwater for heat transfer material. In SCW systems, water is re-circulated between the well and the building (heat pump). It is only a short time since this method has been applied in domestic. So we have to refer to the developed countries' guides and manuals of SCW. In this paper, several design and construction points of SCW method are filed. We used real operation data of SCW system at Chong-Ju Univ. site for economical efficiency analysis. As a result, the payback period of Chong-Ju Univ. site is calculated at 7.23 years.

  • PDF

The application of Large Eddy Simulation in designing the impellers of double-flow-conduits-sewage pump

  • Xue-y QI;Zai-lun Liu;chonl QI;Fan-zhon MENG
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.200-202
    • /
    • 2003
  • In this paper, Gauss filter function is used to filter the N-S equation and the subgrid-scale Reynold stresses model is introduced to deduce the practical form of LES equation for 2-D case for flow calculation of hydraulic machine. Then the LES equation and its discrete form in computational field are obtained in the body-fitted coordinate system and the numerical calculation program is built. The incompressible turbulent flow in double-flow-conduits-sewage pump impeller is computed by using the abovementioned program, and then the distribution rules of velocity and pressure in flow field are obtained. Based on this, the designs of double-flow-conduits-sewage pump impeller are optimized.

  • PDF

탄성 링을 갖는 볼 베어링 지지의 터보 펌프 임계 속도에 관한 연구 (Critical Speeds Evaluation of Turbo Pump Unit with a Elastic-ring Inserted Ball Bearing)

  • 이용복;김창호;곽현덕;하태웅;우유철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.735-743
    • /
    • 2001
  • This study was performed to evaluate the dynamic behavior of turbo pump unit. The acceptable separate margin of 1st critical speed was obtained by the use of elastic-ring inserted ball bearing, while the poor separate margin of 1$\^$st/ critical speed was appeared in the case without the elastic-ring. In addition, the results show that the stiffness and damping of plain seals gain more separate margin of 2nd critical speed. However the wear or the failure of seals could reduce the 2$\^$nd/ critical speeds near the operating speed.

  • PDF

수치 시뮬레이션을 이용한 수직밀폐형 지열시스템의 채열특성에 관한 연구 (Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation)

  • 남유진;오진환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.66-72
    • /
    • 2014
  • Ground source heat pump system can achieve high efficiency of performance by utilizing annually constant underground temperature to provide heat source for space heating and cooling. Generally, the depth of constant-temperature zone under the ground depends on surface heat flux and soil properties. The deeper the ground heat exchanger is installed, the higher the heat exchange rate can be acquired. However, in order to optimally design the system, it is necessary to consider both the installation cost and the system performance. In this study, performance analysis of ground source heat pump system according to the depth has been conducted through the case study.

고체-고체-기체 화학 열펌프 시스템의 반응기 설계에 관한 연구 (A Study on the Reactor Design of Solid-Solid-Gas Chemical Heat Pump System)

  • 김성준;이태희;;최홍규;이종호
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.406-416
    • /
    • 1994
  • In this study the reactor design procedure and method of solid-solid-gas chemical heat pump system using STELF technology were investigated. For manufacturing IMPEX block which is the kernel of reactor, proper salt pair should be selected, and equilibrium temperature drop and COP should be examined for selected salt pair. Moreover, apparent density, residual porosity, and graphite ratio should be calculated to give minimum block volume and mass, and maximum energy density without causing heat and mass transfer problems. Since heat exchange area can be changed with operating condition, reactor diameter, length, and stainless steel thickness should be decided for desired specifications. These procedure and method were applied to the case study of 6kW cold production and 8 hours storage capacity reactor.

  • PDF

탄성 링을 갖는 볼 베어링 지지의 터보 펌프 임계 속도에 관한 연구 (Critical Speeds Evaluation of Turbo Pump Unit with a Elasticring Inserted Ball Bearing)

  • 이용복;김창호;곽현덕;하태웅;우유철
    • 한국유체기계학회 논문집
    • /
    • 제4권2호
    • /
    • pp.22-28
    • /
    • 2001
  • This study was performed to evaluate the dynamic behavior of turbo pump unit. The acceptable separate margin of $1^{st}$ critical speed was obtained by the use of elastic-ring inserted ball bearing, while the poor separate margin of $1^{\st}$ critical speed was appeared in the case without the elastic-ring. In addition, the results show that the stiffness and damping of plain seals give more separate margin of $2^{nd}$ critical speed. However the wear or the failure of seals could reduce the $2^{nd}$ critical speed near the operating speed.

  • PDF