• 제목/요약/키워드: Pump/turbine and motor

검색결과 18건 처리시간 0.024초

Dynamic Simulation of Pump-Storage Power Plants with different variable speed configurations using the Simsen Tool

  • Kruger, Klaus;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.334-345
    • /
    • 2009
  • Pumped storage power plants are playing a significant role in the contribution to the stabilization of an electrical grid, above all by stable operation and fast reaction to sudden load respectively frequency changes. Optimized efficiency and smooth running characteristics both in pump and turbine operation, improved stability for synchronization in turbine mode, load control in pump mode operation and also short reaction times may be achieved using adjustable speed power units. Such variable speed power plants are applicable for high variations of head (e.g. important for low head pump-turbine projects). Due to the rapid development of power semiconductors and frequency converter technology, feasible solutions can be provided even for large hydro power units. Suitable control strategies as well as clear design criteria contribute significantly to the optimal usage of the pump turbine and motor-generators. The SIMSEN tool for dynamic simulations has been used for comparative investigations of different configurations regarding the power converter topology, types of semiconductors and types of motor-generators including the coupling to the hydraulic system. A brief overview of the advantages & disadvantages of the different solutions can also be found in this paper. Using this approach, a customized solution minimizing cost and exploiting the maximum usage of the pump-turbine unit can be developed in the planning stage of new and modernization pump storage projects.

양수발전소용 펌프수차${\cdot}$발전기 전동기 축계의 진동해석 (Vibration Analysis of Pump/Turbine and Generator/Motor Rotor System for Pumped Storage Power Stations)

  • 양보석;최병근;김용한;하현천
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.39-45
    • /
    • 1999
  • Pumped-storage power plants pumps the water from the lower reservoir to the upper reservoir using the extra electric power at night and generates electric power in the daytime. Currently it tends to be a high-head large-capacity machine. In this paper, we developed the computer programs for vibration analysis of the pump/turbine and generator/motor rotor system considering electromagnetic force, hydrodynamic unbalance force, dynamic characteristics of guide bearings and add mass of water. This program was verified by applying it to the real model and calculating the critical speed, natural mode and unbalance response.

  • PDF

터빈방식 연료펌프로 구성된 LPi 연료공급 시스템의 LPG 조성비에 따른 토출성능 및 엔진적용성에 관한 연구 (The Study of Flow Rate Performance and Engine Application with LPG Composition Rate for LPi Fuel Supplying System Consisted of Turbine Type Pump)

  • 임무창;명차리;박심수;박정남;김성근
    • 한국자동차공학회논문집
    • /
    • 제15권3호
    • /
    • pp.99-105
    • /
    • 2007
  • Currently, BLDC fuel pump was applied on LPi vehicle using 3rd fuel supply system as liquified phase LPG injection method had already shown better performance than others. Its cost, however, is rather expensive because of drawbacks such as complicated structure, a fault of localization of system. In this work, demonstration system for a developed turbine type fuel pump to replace BLDC system was setup and investigated. This study results that fuel mass flow rate of turbine type pump and injection performance of injector were better compared to BLDC type. Comparing flow rate of summer LPG with that of winter LPG, the flow rate decreased about 25% using winter LPG. Performance applying turbine type LPi fuel pump to engine is confirmed.

순간 정전시 펌프 구동용 유도전동기의 발전 동작에 관한 연구 (Study on the Generating Operations of the Induction Motor for Driving the Pump During Instantaneous Power Interruption)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.65-70
    • /
    • 2016
  • Power interruption is a phenomenon that no voltage is displayed over a short time or long time. Most devices will not operate normally when the supply voltage is low or does not exist. However, the device can also be operated with a different power which is ensured by a separate power generation. Recently, power interruption has been reduced gradually by the improvement of electricity quality, its duration also has been very short. Induction motors are widely used for the pumping in the water and sewage facilities and power plant applications. The pump is used as a machine for moving the fluid in the high place from a low location. So pump equipment always have a potential energy. If a momentary interruption occurs, the potential energy of the pump is reversed as that of water turbine and motor is operated as generator. This study is an analysis for the voltage variation, current, torque and power flow by the generating operation of the induction motor before and after the change of momentary interruption.

50kW급 로켓 엔진용 전기펌프 모터의 개념 설계 (Conceptual Design of Electric-Pump Motor for 50kW Rocket Engine)

  • 김홍교;곽현덕;최창호;김정
    • 한국항공우주학회지
    • /
    • 제46권2호
    • /
    • pp.175-181
    • /
    • 2018
  • 전기펌프시스템은 기존 터보펌프의 가스발생기, 구동기 및 터빈이 필요 없는 매우 간결한 구조를 갖고 있어 저가 소형 위성 발사체의 차세대 추진기관으로써 최근 주목받고 있다. 그래서 본 논문에서는 로켓엔진용 전기펌프 시스템의 가장 중요한 핵심부품인 영구자석 동기모터(PMSM)의 개발 및 발사체로의 적용 가능성을 파악하기 위하여 50 kW, 50,000 RPM의 성능을 가지는 전기모터에 대한 개념설계안을 도출하였다. 요구되는 전기모터의 성능을 만족시키기 위해서 전자기장해석을 수행하여 모터의 전체 외경과 회전자의 내경을 결정하였으며, 회전자는 4,000 가우스의 Sm2Co17 원통형 자석을 이용하여 Inconel 718 재료의 캔으로 체결하였다. 또한, 엔진구동시 모터 운전 영역에서의 회전 동역학적 안정성을 검증하기 위해서 회전체 동역학해석을 수행하였으며, Campbell 선도를 통하여 설계한 모터의 단품운전 뿐만 아니라 성능확인을 위한 Dynamo meter 운전 시에도 공진현상이 발생하지 않음을 해석적으로 확인할 수 있었다.

웨스팅하우스형 원전의 보조급수계통 설계변경 영향 평가 (A Safety Improvement for the Design Change of Westinghouse 2 Loop Auxiliary Feedwater System)

  • 나장환;배연경;이은찬
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.15-19
    • /
    • 2013
  • The auxiliary feedwater is an important to remove the heat from the reactor core when the main feedwater system is unavailable. In most initiating events in Probabilistic Safety Assessment(PSA), the operaton of this system is required to mitigate the accidents. For one of domestic nuclear power plants, a design change of a turbine-driven auxiliary feedwater pump(TD-AFWP), pipe, and valves in the auxiliary system is implemented due to the aging related deterioration by long time operation. This change includes the replacement of the TD-AFWP, the relocation of some valves for improving the system availability, a new cross-tie line, and the installation of manual valves for maintenance. The design modification affects the PSA because the system is critical to mitigate the accidents. In this paper, the safety effect of the change of the auxiliary feedwater system is assessed with regard to the PSA view point. The results demonstrate that this change can supply the auxiliary feedwater from the TD-AFWP in the accident with the motor-driven auxiliary feedwater pump(MD-AFWP) unavailable due to test or maintenance. In addition, the change of MOV's normal position from "close" to "open" can deliver the water to steam generator in the loss of offsite power(LOOP) event. Therefore, it is confirmed that the design change of the auxiliary feedwater system reduces the total core damage frequency(CDF).

MATLAB/SIMULINK를 이용한 전동기 가변속 구동시스템 모델링 및 시뮬레이션 (Modeling and Simulation with a Variable Speed Drive System of a Electric Motor Using MATLAB/SIMULINK)

  • 정삼용;최연옥;한엄용;오금곤;정수복;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.141-147
    • /
    • 1997
  • The variable speed drive system of a electric motor is popular in industry due to its economical aspect and simplicity of implementation, comparing with a steam turbine or the other engine driven. For a large pumping load like a feedwater pump rated about or more than 20,000㎾, a synchronous motor could be primarily considered. In this paper, we studied the modelling of a variable speed drive system consisted with a load commutated inverter(LCI) and a brushless sailent pole rotor synchronous motor(SM) using MATLAB/SIMULINK. Simulation was performed with a small SM motor parameters.

  • PDF

소형 가스터빈엔진의 시동 및 정상운용구간 제어로직 연구 (Starting and Normal Operation Control Logic Research of Small Gas Turbine Engine)

  • 이경재;이동호;강영석;고성희
    • 한국추진공학회지
    • /
    • 제25권5호
    • /
    • pp.1-9
    • /
    • 2021
  • 국내 소형 가스터빈엔진 상용화 시장의 저변화를 위하여 상용 소형 가스터빈엔진의 시동 및 정상운용구간에서의 제어로직을 파악하고자 하였다. 이를 통하여 시동 및 정상운용구간에서 엔진의 점화 및 정상작동을 위하여 엔진의 점화기, 시동모터, 연료펌프 및 연료밸브가 어떻게 제어되는지 파악하였고, 확보된 제어로직을 실제 상용화 연구가 진행되고 있는 소형 가스터빈엔진의 지상용 제어기에 활용하였다. 해당 엔진은 비행용 엔진 제어기를 제작 중이며, 제작 완료 후 항우연에서 보유하고 있는 고도시험설비를 활용한 고도시험을 통해 비행시험 전에 고도에서의 운용성능을 확인할 예정이다.

펌프의 저 유량 운전특성에 관한 실험적 연구 (An Experimental Study on the Pump Operating Characteristics with Low Flow Operation)

  • 오광석;신필권;박종호;심우건;조두연
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

풍력에너지 이용을 위한 유압식 열변환 장치에 관한 연구 (A Study on Oil Hydraulic Heat Generation System for Wind Energy Utilization)

  • 이일영;공태희
    • 수산해양기술연구
    • /
    • 제31권4호
    • /
    • pp.402-412
    • /
    • 1995
  • 본 연구의 결과를 요약하면 다음과 같다. (1) 유압 펌프, 유량조절 밸브(오리피스)등을 주된 구성 요소로 하는 구조가 간단하고, 운전.관리가 용이한 유압식 풍력.열 변환 장치를 개발하였다. (2) 실험 결과로부터 본 장치의 에너지 변환 효율이 매우 높음을 확인하였다. (3) 출력 에너지가 열 에너지이므로 온수 탱크를 사용하여 쉽게 에너지를 저장할 수 있음을 실험적으로 확인하였다. (4) 본 장치는 대량 생산되는 유압 부품들만을 사용하여 구성이 가능하므로 매우 저렴한 가격으로, 신뢰성이 우수한 장치를 제작할 수 있다

  • PDF