The Effect of Current Pulsing Parameters on the Spatter Generation Rate during $CO_2$Shielded Gas Metal Arc Welding ($CO_2$ 용접에서 전류 펄스 조건이 스패터 발생에 미치는 영향)

  • 강덕일;최재호;장영섭;김용석
    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.63-72
    • /
    • 1998
  • In this study, the effects of the current pulsing conditions, on the spatter generation rate during the $CO_2$ gas metal arc welding (GMAW) were investigated. Normally using the inverter type power supply, of which the welding current waveform was regulated to reduce the spatter generation rate, but in this study pulsing was imposed on the welding current. Observation of the metal transfer phenomena during the pulsed current GMAS indicated that the droplet transfer from the electrode via the short circuit transfer and the repelling transfer mode could be minimized by selecting optimum combinations of pulsing parameters, which include base and peak current, base and pak duration. It was also demonstrated in this study that proper combinations of the pulsing parameters led to reduce generation of spatters during GMAW shielded by $CO_2$ gas.

  • PDF

Development of TCAD calibration methodology for ESD simulation and TLP measurement analysis (ESD 시뮬레이션과 TLP 측정해석을 위한 TCAD calibration methodology 개발)

  • 염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.538-542
    • /
    • 1999
  • New methodology of parameter calibration is proposed for TCAD simulation of nMOSFET in ESD(Electro-Static Discharge) protection circuits. Recently, TLP(Transmission Line Pulsing) measurement has received great interest due to the ability of analyzing device characteristics when ESD pulse is applied to the ESD pulse is applied to the ESD protection circuits. This paper describes new methodology of analyizing TLP measurement, TCAD simulation, and parameter calibration.

  • PDF

Selective etching of SiO2 using embedded RF pulsing in a dual-frequency capacitively coupled plasma system

  • Yeom, Won-Gyun;Jeon, Min-Hwan;Kim, Gyeong-Nam;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.136.2-136.2
    • /
    • 2015
  • 반도체 제조는 chip의 성능 향상 및 단가 하락을 위해 지속적으로 pattern size가 nano size로 감소해 왔고, capacitor 용량은 증가해 왔다. 이러한 현상은 contact hole의 aspect ratio를 지속적으로 증가시킨바, 그에 따라 최적의 HARC (high aspect ratio contact)을 확보하는 적합한 dry etch process가 필수적이다. 그러나 HARC dry etch process는 많은 critical plasma properties 에 의존하는 매우 복잡한 공정이다. 따라서, critical plasma properties를 적절히 조절하여 higher aspect ratio, higher etch selectivity, tighter critical dimension control, lower P2ID과 같은 plasma characteristics을 확보하는 것이 요구된다. 현재 critical plasma properties를 제어하기 위해 다양한 plasma etching 방법이 연구 되어왔다. 이 중 plasma를 낮은 kHz의 frequency에서 on/off 하는 pulsed plasma etching technique은 nanoscale semiconductor material의 etch 특성을 효과적으로 향상 시킬 수 있다. 따라서 본 실험에서는 dual-frequency capacitive coupled plasma (DF-CCP)을 사용하여 plasma operation 동안 duty ratio와 pulse frequency와 같은 pulse parameters를 적용하여 plasma의 특성을 각각 제어함으로써 etch selectivity와 uniformity를 향상 시키고자 하였다. Selective SiO2 contact etching을 위해 top electrode에는 60 MHz pulsed RF source power를, bottom electrode에는 2MHz pulse plasma를 인가하여 synchronously pulsed dual-frequency capacitive coupled plasma (DF-CCP)에서의 plasma 특성과 dual pulsed plasma의 sync. pulsing duty ratio의 영향에 따른 etching 특성 등을 연구 진행하였다. 또한 emissive probe를 통해 전자온도, OES를 통한 radical 분석으로 critical Plasma properties를 분석하였고 SEM을 통한 etch 특성분석과 XPS를 통한 표면분석도 함께 진행하였다. 그 결과 60%의 source duty percentage와 50%의 bias duty percentage에서 가장 향상된 etch 특성을 얻을 수 있었다.

  • PDF

Acoustic Nonlinear Characteristics of Ultrasonic Wave Reflected at Contact Interfaces (접촉계면 반사 초음파의 음향 비선형 특성)

  • Park, Byung-Jun;Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.40-46
    • /
    • 2011
  • In the field application of the conventional acoustic nonlinear technique using through transmission of bulk waves to evaluate the contact acoustic nonlinearity(CAN) in solid-solid contact interfaces like as in the closed crack, it has difficulty to access inner position for attaching the pulsing or receiving transducer. In the present study, a new reflection technique has been suggested to measure the acoustic nonlinearity in solid-solid contact interfaces, which uses both of pulsing and receiving transducers on the same side of target and so that it will be very useful for the field application. For this, based on the linear and the nonlinear contact stiffness estimated by the power-model of the contacting pressure, the nonlinear parameter of the reflected ultrasonic wave at the interfaces has been theoretically calculated. Experimental results in contact interfaces of A1606l-T6 alloy specimens with loading pressure showed good agreement with the theoretical predictions, which proves the validity of the suggested reflection mode technique.

High accuracy position control of pneumatic rodless cylinder using LVQNN (LVQNN을 이용한 공압 로드리스 실린더의 고정도 위치제어)

  • 표성만;정민화;안경관;이병룡;양순용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1012-1017
    • /
    • 2003
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to a variety of practical positioning applications with various external loads is described in this paper. A novel modified pulso width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of standard PWM technique and that of the novel modified PWM technique shows that the control performance is significantly increased. A state feedback controller with position, velocity and acceleration feedback is successfully implemented as the continuous controller. Switching algorithm of control parameter using learning vector quantization neural network (LVQNN) is newly proposed. which estimates the external loads of the pneumatic actuator. The effectiveness of the proposed control algorithms are demonstrated through experiments with various loads.

  • PDF

Intelligent Control of Pneumatic Actuator using On/Off Valve (On/Off 밸브를 이용한 공압 실린더의 지능제어)

  • 안경관;표성만;송인성;이병룡;양순용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.86-93
    • /
    • 2003
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to a variety of practical positioning applications with various external loads is described in this paper. A novel modified pulse width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of standard PWM technique and that of the novel modified PWM technique shows that the control performance is significantly increased. A state feedback controller with position, velocity and acceleration feedback is successfully implemented as the continuous controller. Switching algorithm of control parameter using learning vector quantization neural network (LVQNN) is newly proposed, which estimates the external loads of the pneumatic actuator. The effectiveness of the proposed control algorithms are demonstrated through experiments with various loads.

침대면 전극구조에서 전원 회로에 의한 대기압 스트리머-스파크 방전의 방전 제어 및 시뮬레이션

  • Lee, Je-Hyeon;Kim, Dong-Hyeon;Lee, Hae-Jun;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.157.2-157.2
    • /
    • 2013
  • 현재 산업에서 상압 플라즈마는 생물의학, 표면처리, 용접 및 절단, 화학적 오염제거 등 여러 분야에서 각광받고 있으며 그 잠재력 또한 매우 크다. 통상적으로 글로우 방전은 생물의학, 표면처리, 화학적 오염제거 등에 주로 쓰이고 아크 방전은 용접 및 절단에 응용된다. 이처럼 상압 플라즈마는 여러 가지 방전으로 분류되고 그 특성에 맞게 응용되고 있는데 이러한 산업 여러 분야에 적절히 응용하기 위해서는 각 플라즈마에 대한 진단과 특성 분석이 선행적으로 이루어져야 한다. 또한, 전원회로의 특성에 따라 플라즈마 특성에 어떤 영향을 미치는지에 대한 연구도 매우 활발히 진행되고 있다. 본 연구에서는 침 대 면 전극구조에서 고전압 dc전원이 RC시정수에 따라 repetition frequency가 변하는 전원 회로의 여러 parameter에 따라 스트리머-스파크 방전의 전기적 특성이 어떻게 변하는지 연구한다. 또한, 시뮬레이션을 통해 실험에 대한 예측, 비교를 목표로 한다.

  • PDF

The Characteristics of Voice Onset Time of the Korean Stops in the Benign Laryngeal Disorders (후두질환에 따른 자음의 음성발현시간의 특성)

  • Hong, Ki-Hwan;Lee, Hwa-Uk;Kim, Jin-Sung;Lee, Eun-Jung;So, Sang-Soo;Choi, Dong-Il;Ynng, Yoon-Soo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.98-102
    • /
    • 2006
  • Background and Objectives : Voice onset time(VOT) is defined as the time interval from oral release of a stop consonant to the onset of glottal pulsing in the following vowel. VOT is a temporal characteristics of stop consonants that reflects the complex timing of glottal articulation relative to supraglottal articulation. Stop consonants are characterized by creation of a pressure difference across a complete occlusion in the vocal tract, followed by a sudden release 'burst' due to opening that occlusion. The objects of this study is to evaluate a usefulness of voice onset time in the assessment of voice disorderd patients. Subjects : Subjects were 20 adults with normal voice and with benign laryngeal disorders. Subjects with voice disorders represented the following vocal pathologies : vocal polyp, vocal nodule, Reinke's edema and unilateral vocal fold paralysis(UVFP). Control subjects were matched for age (21-40 yews old) and sex(male) with the voice disorders subjects and had normal vocal qualities with no history of voice disorders. Methods : Each voice-disordered and matched control subject read the test passages containing three types of Korean bilabial consonants. VOT measures were made for the initial $/p/p^h/\;and\;/p'/$. VOT was measured using acoustic waveform or wide band spectrogram. Results : For each voiceless stop consonants, there was a significant difference in VOT between the voice disordered and normal subjects. The mean VOTs of the lax stops in UVFP was significantly shorter than those of control subjects in the UVFP. The mean VOTs of the aspirated stops in the vocal polyp and nodule were longer than those of control subjects, but not significant. The mean VOTs of the glottalized in voice disordered groups were longer than those of control subjects, and significant statistically in the UVFP. Conclusions : VOT may be a clinically useful acoustic parameter in the assessment of voice disordered patients, especially in the unilateral vocal fold paralysis.

  • PDF