• 제목/요약/키워드: Pulsed-ultrasound

검색결과 96건 처리시간 0.027초

당뇨유도 백서 경골에 티타늄 임플란트 매식 시 지방조직 유래 줄기세포 주입 후 저출력 초음파 적용이 골치유에 미치는 영향 (Effect on bone healing by the application of low intensity pulsed ultrasound after injection of adipose tissue-derived stem cells at the implantation of titanium implant in the tibia of diabetes-induced rat)

  • 정태영;박상준;황대석;김용덕;이수운;김욱규
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권4호
    • /
    • pp.301-311
    • /
    • 2011
  • Introduction: This study examined the effect of the application of low intensity pulsed ultrasound on bone healing after an injection of adipose tissue-derived stem cells (ADSCs) during the implantation of a titanium implant in the tibia of diabetes-induced rats. Materials and Methods: Twelve Sprague-Dawely rats were used. After inducing diabetes, the ADSCs were injected into the hole for the implant. Customized screw type implants, 2.0 mm in diameter and 3.5 mm in length, were implanted in both the tibia of the diabetes-induced rats. After implantation, LIPUS was applied with parameters of 3 MHz, 40 mW/$cm^2$, and 10 minutes for 7 days to the left tibiae (experimental group) of the diabetesinduced rats. The right tibiae in each rat were used in the control group. At 1, 2 and 4 week rats were sacrificed, and the bone tissues of both tibia were harvested. The bone tissues of the three rats in each week were used for bone-to-implant contact (BIC) and bone area (BA) analyses and the bone tissues of one rat were used to make sagittal serial sections. Results: In histomorphometric analyses, the BIC in the experimental and control group were respectively, $39.00{\pm}18.17%$ and $42.87{\pm}9.27%$ at 1 week, $43.74{\pm}6.83%$ and $32.27{\pm}6.00%$ at 2 weeks, and $32.62{\pm}11.02%$ and $47.10{\pm}9.77%$ at 4 weeks. The BA in experimental and control group were respectively, $37.28{\pm}3.68%$ and $31.90{\pm}2.84%$ at 1 week, $20.62{\pm}2.47%$ and $15.64{\pm}2.69%$ at 2 weeks, and $11.37{\pm}4.54%$ and $17.69{\pm}8.77%$ at 4 weeks. In immunohistochemistry analyses, Osteoprotegerin expression was strong at 1 and 2 weeks in the experimental group than the control group. Receptor activator of nuclear factor kB ligand expression showed similar staining at each week in the experimental and control group. Conclusion: These results suggest that the application of low intensity pulsed ultrasound after an injection of adipose tissue-derived stem cells during the implantation of titanium implants in the tibia of diabetes-induced rats provided some positive effect on bone regeneration at the early stage after implantation. On the other hand, this method is unable to increase the level of osseointegration and bone regeneration of the implant in an uncontrolled diabetic patient.

DEFECT DETECTION WITHIN A PIPE USING ULTRASOUND EXCITED THERMOGRAPHY

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.637-646
    • /
    • 2007
  • An UET (ultrasound excited thermography) has been used for several years for a remote non-destructive testing in the automotive and aircraft industry. It provides a thermo sonic image for a defect detection. A thermograhy is based On a propagation and a reflection of a thermal wave, which is launched from the surface into the inspected sample by an absorption of a modulated radiation. For an energy deposition to a sample, the UET uses an ultrasound excited vibration energy as an internal heat source. In this paper the applicability of the UET for a realtime defect detection is described. Measurements were performed on two kinds of pipes made from a copper and a CFRP material. In the interior of the CFRP pipe (70mm diameter), a groove (width - 6mm, depth - 2.7mm, and length - 70mm) was engraved by a milling. In the case of the copper pipe, a defect was made with a groove (width - 2mm, depth - 1mm, and length - 110 mm) by the same method. An ultrasonic vibration energy of a pulsed type is injected into the exterior side of the pipe. A hot spot, which is a small area around the defect was considerably heated up when compared to the other intact areas, was observed. A test On a damaged copper pipe produced a thermo sonic image, which was an excellent image contrast when compared to a CFRP pipe. Test on a CFRP pipe with a subsurface defect revealed a thermo sonic image at the groove position which was a relatively weak contrast.

왕수를 이용한 중금속 오염토양에서의 추출방안 연구 (Heavy Metals Extraction from Contaminated Soils using Aqua Regia Extraction)

  • 이덕영;정선국;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권2호
    • /
    • pp.15-22
    • /
    • 2018
  • Aqua regia extraction for the quantification of heavy metals and As in contaminated soils was investigated as one of preliminary steps for on-site monitoring using sensor technology. Soil samples were taken from closed railway depot, closed mines, and closed refinery and various extraction conditions including $30^{\circ}C/15min$, $30^{\circ}C/30min$, $30^{\circ}C/60min$, $30^{\circ}C/120min$, $80^{\circ}C/15min$, $80^{\circ}C/30min$, $80^{\circ}C/60min$, $80^{\circ}C/120min$ were tested. The optimal extraction condition was determined as $80^{\circ}C/60min$ because the extraction efficiencies of Zn were relatively low and did not reach the targeted level (80-100% of original concentrations) for $30^{\circ}C$ conditions. It was found that the fractionation of heavy metals and As using the sequential extraction method was useful to understand the degree of metal extraction. In order to enhance the extraction efficiency within short extraction time, ultrasound technology using a 20 kHz horn-type sonicator was additionally used for $30^{\circ}C/15min$. It was revealed that ultrasound could significantly enhance the extraction efficiency and pulsed irradiation showed higher efficiency than continuous irradiation due to the less formation of bubble clouds. However high temperature condition ($80^{\circ}C$) was required to achieve high extraction efficiency for Zn in spite of the use of ultrasound.

유방암 동물모델에서의 저강도 집속초음파를 이용한 마이크로버블 및 마이크로버블-나노물질 복합체 기반 항암제 전달 효율 검증 (Effects of Anticancer Drug Delivery based on Microbubble and Microbubble-Nanoparticle Complex using Low-Intensity Focused Ultrasound in Breast Cancer Animal Model)

  • 백희규;하신우;허형규;정병진;한문;문형원;김상균;이학종;박주영
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.39-47
    • /
    • 2019
  • Ultrasound sonication along with microbubble (MB) could enhance drug delivery to promote the absorption of anticancer drugs into cancers in a noninvasive and targeted manners. In this study, we verify the acute drug delivery enhancement (within an hour) of two representative focused ultrasound driven drug delivery enhancement methods (MB and Doxorubicin-coated Nanoparticle complex (MB-NP) based). Experiments were conducted using in vivo mouse model with MDA-MB-231 breast cancer cell line. Ultrasound generated by single-element 1 MHz focused ultrasound transducer was delivered in pulsed sonication consisted of 0.125 msec bursts at a pulse repetition frequency of 2 Hz for 20 seconds without a significant increase in local temperature (less than $0.1^{\circ}C$) or hemorrhage. Doxorubicin concentrations in tumors were improved by 1.97 times in the case of MB-NP, and 1.98 times by using Doxorubicin and MB separately. These results indicate anticancer drug delivery based on MB and MB-NP can significantly improve the effect of anticancer drugs delivered to tumors in a short time period by using low-intensity focused ultrasound.

Biophysical therapy and biostimulation in unfavorable bony circumstances: adjunctive therapies for osseointegration

  • Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권4호
    • /
    • pp.195-203
    • /
    • 2012
  • Dental implants using titanium have greatly advanced through the improvement of designs and surface treatments. Nonetheless, the anatomical limits and physiological changes of the patient are still regarded as obstacles in increasing the success rate of implants further, even with the enhancement of implant products. So there have been many efforts to overcome these limits. The intrinsic potential for bone regeneration can be stimulated through adjuvant treatments with the continuous improvement of implant properties, and this can play an important role in achieving optimum osseointegration toward peripheral bone tissue and securing ultimate long-term implant stability in standard surgical procedures. For this purpose, various chemical, biological, or biophysical measures were developed such as bone grafts, materials, pharmacological agents, growth factors, and bone formation proteins. The biophysical stimulation of bone union includes non-invasive and safe methods. In the beginning, it was developed as a method to enhance the healing of fractures, but later evolved into Pulsed Electromagnetic Field, Low-Intensity Pulsed Ultrasound, and Low-Level Laser Therapy. Their beneficial effects were confirmed in many studies. This study sought to examine bone-implant union and its latest trend as well as the biophysical stimulation method to enhance the union. In particular, this study suggested the enhancement of the function of cells and tissues under a disadvantageous bone metabolism environment through such adjunctive stimulation. This study is expected to serve as a treatment guideline for implant-bone union under unfavorable circumstances caused by systemic diseases hampering bone metabolism or the host environment.

Frequency Characteristics of Surface Wave Generated by Single-Line Pulsed Laser Beam with Two Kinds of Spatial Energy Profile Models: Gaussian and Square-Like

  • Seo, Ho-Geon;Kim, Myung-Hwan;Choi, Sung-Ho;Kim, Chung-Seok;Jhang, Kyung-Young
    • 비파괴검사학회지
    • /
    • 제32권4호
    • /
    • pp.347-354
    • /
    • 2012
  • Using a single-line pulsed laser beam is well known as a useful noncontact method to generate a directional surface acoustic wave. In this method, different laser beam energy profiles produce different waveforms and frequency characteristics. In this paper, we considered two typical kinds of laser beam energy profiles, Gaussian and square-like, to find out a difference in the frequency characteristics. To achieve this, mathematical models were proposed first for Gaussian laser beam profile and square-like respectively, both of which depended on the laser beam width. To verify the theoretical models, experimental setups with a cylindrical lens and a line-slit mask were respectively designed to produce a line laser beam with Gaussian spatial energy profile and square-like. The frequency responses of the theoretical models showed good agreement with experimental results in terms of the existence of harmonic frequency components and the shift of the first peak frequencies to low.

흰쥐의 관절연골에서 맥동전자장과 맥동초음파가 HSP70의 과발현을 통한 연골형성에 미치는 영향 (Pulsed Electromagnetic Field and Pulsed Ultrasound Increases Chondrogenesis through HSP70 Overexpression in Rat Articular Cartilage)

  • 구현모
    • 대한물리의학회지
    • /
    • 제8권1호
    • /
    • pp.111-116
    • /
    • 2013
  • 연구목적: 본 연구는 흰쥐를 대상으로 정강뼈의 관절연골에 적용한 맥동전자장과 맥동초음파가 HSP70(Heat shock protein 70)의 발현을 통한 연골 형성에 미치는 영향을 알아보고자 실시하였다. 연구방법: 36마리의 200~250g의 Sprague-Dawley 흰쥐를 대조군, 맥동전자장 적용군, 맥동초음파 적용군으로 각 집단별로 12마리씩 무작위 배정하여 실험을 진행하였다. 맥동전자장은 27.12 MHz의 주파수, 5가우스의 강도, 450 W의 출력으로 10분간 적용하였고, 맥동초음파는 20%의 맥동비, 1MHz의 주파수, $1.5W/cm^2$의 강도로 10분간 적용하였다. 연구결과: 맥동전자장 적용군과 맥동초음파 적용군의 관절연골 조직에서 유의한 수준의 HSP70 발현량을 나타냈다. 또한 맥동전자장 적용군과 맥동초음파 적용군에서는 Akt, Erk1, CREB의 높은 활성도를 나타내었고, 맥동초음파 적용군에 비해서 맥동전자장 적용군의 더 높은 수준의 활성도를 보였다. 결론: 맥동전자장과 맥동초음파는 HSP70의 과발현을 유발하고, 이를 통해 연골형성을 증가시키는 것으로 나타나, 향후 관절연골의 손상에 대한 임상적 적용을 위한 추가적인 연구가 진행되어야 할 것으로 생각된다.

Crack localization by laser-induced narrowband ultrasound and nonlinear ultrasonic modulation

  • Liu, Peipei;Jang, Jinho;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.301-310
    • /
    • 2020
  • The laser ultrasonic technique is gaining popularity for nondestructive evaluation (NDE) applications because it is a noncontact and couplant-free method and can inspect a target from a remote distance. For the conventional laser ultrasonic techniques, a pulsed laser is often used to generate broadband ultrasonic waves in a target structure. However, for crack detection using nonlinear ultrasonic modulation, it is necessary to generate narrowband ultrasonic waves. In this study, a pulsed laser is shaped into dual-line arrays using a spatial mask and used to simultaneously excite narrowband ultrasonic waves in the target structure at two distinct frequencies. Nonlinear ultrasonic modulation will occur between the two input frequencies when they encounter a fatigue crack existing in the target structure. Then, a nonlinear damage index (DI) is defined as a function of the magnitude of the modulation components and computed over the target structure by taking advantage of laser scanning. Finally, the fatigue crack is detected and localized by visualizing the nonlinear DI over the target structure. Numerical simulations and experimental tests are performed to examine the possibility of generating narrowband ultrasonic waves using the spatial mask. The performance of the proposed fatigue crack localization technique is validated by conducting an experiment with aluminum plates containing real fatigue cracks.

PW 도플러 시스템에서 Base Line 이동 기법을 이용한 오디오 신호 처리 방법 (Audio Processing Algorithm Using Base Line Shift Method in Pulsed Doppler Systems)

  • 김기덕;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권3호
    • /
    • pp.275-281
    • /
    • 1999
  • 현재 널리 쓰이고 있는 PW 도플러 시스템 주파수가 나이퀴스트 주파수를 초과할 경우 스텍트럼 aliasing 현상에 의하여 정확한 혈류 속도의 측정을 할 수 없다는 문제점을 가지고 있다 . 도플러 스펙트럼의 aliasing 현상을 극복하기 위하여 통상적으로 기준선 (Base Line) 이동기법을 사용하고 있으나 도플러 오디오 신호는 aliasing 된채로 남게 된다. 이 논문에서는 주파수 천이 및 필터링 기법들을 적절히 적용하여 기준선 이동시 도플러 스텍트럼과 오디오 신호의 aliasing 현상을 함께 제거할 수 있는 기법을 제안한다. 제안된 방법은 단방향 혈류 성분을 검사하는 경우 aliasing 현상 없이 측정 가능한 도플러 주파수를 나이퀴스트 주파수의 두배인 PRF 까지 증가되도록 한다. 실제 시스템에서 얻어진 신호를 이용하여 제안된 방법을 실험적으로 검증하였다.

  • PDF

Methods for improving meat protein digestibility in older adults

  • Seung Yun Lee;Ji Hyeop Kang;Da Young Lee;Jae Won Jeong;Jae Hyeon Kim;Sung Sil Moon;Sun Jin Hur
    • Journal of Animal Science and Technology
    • /
    • 제65권1호
    • /
    • pp.32-56
    • /
    • 2023
  • This review explores the factors that improve meat protein digestibility and applies the findings to the development of home meal replacements with improved protein digestion rates in older adults. Various methods improve the digestion rate of proteins, such as heat, ultrasound, high pressure, or pulse electric field. In addition, probiotics aid in protein digestion by improving the function of digestive organs and secreting enzymes. Plant-derived proteases, such as papain, bromelain, ficin, actinidin, or zingibain, can also improve the protein digestion rate; however, the digestion rate is dependent on the plant enzyme used and protein characteristics. Sous vide processing improves the rate and extent of protein digestibility, but the protein digestion rate decreases with increasing temperature and heating time. Ultrasound, high pressure, or pulsed electric field treatments degrade the protein structure and increase the proteolytic enzyme contact area to improve the protein digestion rate.