• 제목/요약/키워드: Pulsed laser

검색결과 1,243건 처리시간 0.028초

Laser와 PZT - Target간의 반응과 그에 따른 Plume 형성 및 입자 방출에 관한 연구 (Interaction of Laser Beam with PZT - Target and Observation of Laser - Induced Plume and Particle Ejection)

  • 이병우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권5호
    • /
    • pp.93-102
    • /
    • 1996
  • Laser-induced plume and laser-target interaction during pulsed laser deposition are demonstrated for a lead zirconate titanate (PZT). A KrF excimer laser (wavelength 248nm) was used and the laser was pulsed at 20Hz, with nominal pulse width of 20ns. The laser fluence was~$16J/cm^2,$ with 100mJ per pulse. The laser-induced plasma plume for nanosecond laser irradiation on PZT target has been investigated by optical emission spectra using an optical multichannel analyzer(OMA) and by direct observation of the plume using an ICCD high speed photography. OMA analysis showed two distinct ionic species with different expansion velocities of fast or slow according to their ionization states. The ion velocity of the front surface of the developing plume was about $10^7$cm/sec and corresponding kinetic energy was about 100eV. ICCD photograph showed another kind of even slower moving particles ejected from the target. These particles considered expelled molten parts of the target. SEM morphologies of the laser irradiated targets showed drastic melting and material removal by the laser pulse, and also showed the evidence of the molten particle ejection. The physics of the plasma(plume) formation and particle ejection has been discussed.

  • PDF

펄스레이저 증착법의 레이저 파장변환에 의한 실리콘 나노결정의 발광 특성 연구 (Study on the Luminescence of Si Nanocrystallites on Si Substrate fabricated by Changing the Wavelength of Pulsed Laser Deposition)

  • 김종훈;전경아;최진백;이상렬
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권4호
    • /
    • pp.169-172
    • /
    • 2003
  • Silicon nanocrystalline thin films on p-type (100) silicon substrate have been fabricated by pulsed laser deposition technique using a Nd:YAG laser with the wavelength of 355, 532, and 1064 nm. The base vacuum in the chamber was down to $10^-6$ Torr and the laser energy densities were 1.0~3.0 J/$\textrm{cm}^2$ After deposition, silicon nanocrystalline thin films have been annealed at nitrogen gas. Strong Blue and green luminescence from silicon nanocrystalline thin films have been observed at room temperature by photoluminescence and its peak energies shift to green when the wavelength is increased from 355 to 1064 nm.

초음파 진동과 레이저 후면 에칭을 통한 유리 구멍 가공 (Glass Drilling using Laser-induced Backside Wet Etching with Ultrasonic Vibration)

  • 김혜미;박민수
    • 한국정밀공학회지
    • /
    • 제31권1호
    • /
    • pp.75-81
    • /
    • 2014
  • Laser beam machining has been known as efficient for glass micromachining. It is usually used the ultra-short pulsed laser which is time-consuming and uneconomic process. In order to use economic and powerful long pulsed laser, indirect processing called laser-induced backside wet etching (LIBWE) is good alternative method. In this paper, micromachining of glass using Nd:YAG laser with nanosecond pulsed beam has been attempted. In order to improve shape accuracy, combined processing with magnetic stirrer has been widely used. Magnetic stirrer acts to circulate the solution and remove the bubble but it is not suitable for deep hole machining. To get better effect, ultrasonic vibration was applied for improving shape accuracy.

Nd:YAG 레이저 조사에 의한 치아 및 구강점막의 마취효과 (A Study on the Anesthetic Effects of Pulsed Nd:YAG Laser Irradiation to the Oral Mucosa and the Teeth)

  • 최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제23권1호
    • /
    • pp.1-9
    • /
    • 1998
  • The aim of the study was to evaluate the anesthetic Effecs of pulsed Nd:YAG laser irradiation to the oral mucosa and the teeth. Twenty subjects who didn't have a history of significant systemic or current oral disease were included in this study. All the subjects were divided randomly into the experimental group and the control group with 10 for each group. Pain thresholds were measured with Weighted Needle Pinprick Sensory Threshold Test for the mucosal surface of lower lip and with electric pulp test for the upper right central incisor respectively, before and immediately after pulsed Nd:YAG laser irradiation in the condition of 2 watt, 20pps for 2 minute at 10mm distance. The experiment was double-blinded clinical trial. The results were as follows : 1. The mean pain threshold of the mucosal surface of lower lip for Weighted Needle Pinprick Sensory Threshold Test was 2.94(1.00g for the contral group respectively, and there was no statistical difference between two groups. 2. The mean pain threshold of the mucosal surface of lower lip was significantly increased immediately after pulsed Nd:YAG laser irradiation. 3. The mean pain threshold of the upper right central incisor for eledtric pulp test was 34.50(4.97V in the experimental group and 34.00(13.08V in the control group respectively, and there was no statistical difference between two groups. 4. The mean pain threshold of the upper right central incisor was significantly increased immediately after pulsed Nd:YAG laser irradiation.

  • PDF

극초단 펄스 레이저에 의한 절연체의 광학 손상 해석 (Numerical Analysis of Optical Damage in Dielectrics Irradiated by Ultra-Short Pulsed Lasers)

  • 이성혁;강관구;이준식;최영기;박승호;유홍선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1213-1218
    • /
    • 2004
  • The present article reports extensive numerical results on the non-local characteristics of ultra-short pulsed laser-induced breakdowns of fused silica ($SiO_{2}$) by using the multivariate Fokker-Planck equation. The nonlocal type of multivariate Fokker-Planck equation is modeled on the basis of the Boltzmann transport formalism to describe the ultra-short pulsed laser-induced damage phenomena in the energy-position space, together with avalanche ionization, three-body recombination, and multiphoton ionization. Effects of electron avalanche, recombination, and multiphoton ionization on the electronic transport are examined. From the results, it is observed that the recombination becomes prominent and contributes to reduce substantially the rate of increase in electron number density when the electron density exceeds a certain threshold. With very intense laser irradiation, a strong absorption of laser energy takes place and an initially transparent solid is converted to a metallic state, well known as laser-induced breakdown. It is also found that full ionization is provided at intensities above threshold, all further laser energy is deposited within a thin skin depth.

  • PDF

A Study on Hair Removal Characteristics Using a Long-pulsed Alexandrite Laser

  • Choi Jin-Young;Kim Sang-Gil;Park Jong-Woong;Park Sung-Joon;Kim Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권1호
    • /
    • pp.33-38
    • /
    • 2005
  • Recently, lasers have become widely used throughout the medical treatment field. Several types of lasers have been used for the purpose of hair removal since the Alexandrite laser was approved by the FDA (Food & Drug Administration) for clinical epilation. In this study, a long-pulsed Alexandrite laser system for hair removal adopting a multi-discharge method in which three flash lamps are turned on consecutively was designed and fabricated. This laser system shows the technology that makes it possible to create extended pulse by turning on three flash lamps consecutively. With this technique, the pulse width can be varied from 4ms∼10ms. Then using this Alexandrite laser system with the pulse width 10ms and the beam size 7mm, hair removal was performed on the back portion of a human hand and leg. This study shows that treatment by the long-pulsed Alexandrite laser produces hair removal with no relevant side effects.

레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구 (TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY)

  • 안현정;김현철;최병갑;송언희;김래경
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

Pulsed Laser에 의하여 가열되는 불투명 고체의 열전달 해석 (Heat Transfer Analysis of the Opaque Solid Heated by Pulsed Laser)

  • 전민호;이은호;유재석
    • 에너지공학
    • /
    • 제8권1호
    • /
    • pp.181-188
    • /
    • 1999
  • 재료의 표면을 pulsed laser로 가열할 때, 유한한 두께를 가지는 반무한 평판의 온도분포를 해석하여 열확산계수, 재료의 두께, 열원의 주기, 그리고 열원의 반경이 온도분포에 미치는 영향을 알아보았다. Pulsed laser에 의하여 가열되는 불투명 고체의 시간에 따른 온도는 전체적으로 증가하지만 열원의 주기와 동일한 주기를 가지고 일정한 온도차를 가지는 전체온도와 평균온도의 차, Tac가 존재한다. 열확산계수가 증가하면 재료 내부로 에너지의 확산이 활발하기 때문에 Tac는 커진다. 재료의 두께가 열확산길이보다 얇은 경우에는 두께변화에 따라서 온도가 민감하게 변하지만, 열확산길이보다 재료의 두께가 두꺼울 때는 두께의 변화에 관계없이 거의 일정한 온도가 나타난다. 열원의 단속주파수가 증가하면 한 주기당 에너지가 작아지므로 Tac의 크기는 작아진다. 열원의 반경이 커지면 단위면적당 에너지가 감소하므로 Tac의 크기는 삼각파, 싸인파, 사각파 순으로 크게 나타난다. 따라서 열원의 파형을 측정하여 이를 적용하는 것이 바람직하다.

  • PDF