• 제목/요약/키워드: Pulsed electric discharge

검색결과 38건 처리시간 0.024초

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성 (Discharge characteristics of FFL as applied voltage variation)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

3전극 트리거 갭 스위치 동작특성에 관한 연구 (A Study on Operation Characteristics of Three Electrode Trigger Gap Switch)

  • 홍태윤;한상보
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.

누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구 (A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary)

  • 정현주;이동훈;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

$N_{2}/O_{2}$ 혼합가스에서 펄스코로나 방전을 이용한 NOx 제거 모델링에 관한 연구 (DeNOx modeling in $N_{2}/O_{2}$ gas by pulsed corona discharge)

  • 박광서;이형상;전배혁;신현호;윤웅섭;전광민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.117-128
    • /
    • 1999
  • The removal of nitrogen oxides(NOx) from $N_{2}/O_{2}$ gas using a pulsed corona discharge was investigated as a function of the reduced electric field(E/N) and the energy density(J/L). A kinetic model was developed to characterize the chemical reactions taking place in a pulsed corona discharge reactor. The model calculates the fractional concentrations of radical species at each pulse-on period and utilizes the radicals to remove NOx for the subsequent pulse-off period. Electron collision reaction data are calculated using ELENDIF program to solve Boltzmann equation for electron energy distribution function, and the subsequent chemical reactions are calculated using CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement with the experimental data, and predicts the formation of other species such as $NO_{2}$, $O_{3}$ and $N_{2}O$.

  • PDF

Low-Pressure Mercury-Free Fluorescent Lamp for General Lighting

  • Jinno, Masafumi;Lee, Jong-Chan;Motomural, Hideki;Aono, Masaharu;Park, Dae-Hee
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper we report on development of our original mercury-less fluorescent lamps for general lighting. These new-type lamps have multi-pairs of electrodes to maintain multi-discharge paths and to keep positive column diffused state. The omission characteristics oft the lamps were investigated. These discharge lamps were operated by pulsed discharge. By using multi-pairs of electrodes for xenon pulsed discharge fluorescent lamps, higher intensity of luminance was obtained than the conventional type of lamps using single pair of electrodes. Recently this type of lamp achieved over $9000\;cd/m^2$ and 50 lm/W.

  • PDF

펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과 (Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization)

  • 엄세은;장인성
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.16-23
    • /
    • 2018
  • 하 폐수 슬러지 발생량의 꾸준한 증가로 인해 폐 슬러지의 효율적인 처리 기술개발이 요구되고 있다. 본 연구에서는 PEF (Pulsed Electric Fields) 기술을 활용하여 슬러지의 가용화를 통한 감량화 가능성을 평가하였다. PEF에 사용되는 스테인레스 재질의 전극에 테프론과 에폭시로 코팅한 후 활성슬러지 혼합액에 전계 펄스를 인가하여 전극 코팅에 따른 가용화 효율을 평가하였다. 또한 인가된 전압의 세기를 6, 12, 15 kV로 변화시켜 가며 가용화 정도를 평가하였다. 에폭시 코팅 전극에서는 MLSS, 용존성-COD, -TN, -TP를 분석한 결과 슬러지의 가용화가 발생하지 않은 것으로 나타났다. 그러나 테프론으로 코팅한 전극에서는 MLSS는 최대 9 % 감소하였고 MLVSS 역시 최대 10 % 감소하였다. 또한 용존성-COD는 최대 496 % 증가하였다. 인가전압 6 kV 하에서는 가용화가 거의 발생하지 않았으나, 12 kV와 15 kV의 전압에서는 슬러지 가용화가 발생한 것으로 나타났다. 또한 슬러지 가용화가 발생한 12 kV와 15 kV의 전압에서는 코로나가 발생한 것으로 보아 슬러지 가용화는 코로나에 의해 유도되었으며, 코로나가 발생하는 임계전압이 존재하는 것으로 판단되었다. 결론적으로 PEF의 인가전압과 적절한 코팅제를 선택하여 코로나 발생을 제어함으로써 슬러지의 가용화를 유도할 수 있음을 확인하였다.

펄스방전 확공형 앵커의 하중전이에 관한 연구 (Load Transfer on Pulsed Power Discharge Anchors)

  • 김성규;김낙경;김재원;주용선;김선주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF

직류 방전과 펄스 직류 방전에 의한 플라즈마 형상 관찰 (Observation of Plasma Shape by Continuous dc and Pulsed dc)

  • 양원균;주정훈
    • 한국표면공학회지
    • /
    • 제42권3호
    • /
    • pp.133-138
    • /
    • 2009
  • Effects of bipolar pulse driving frequency between 50 kHz and 250 kHz on the discharge shapes were analyzed by measuring plasma characteristics by OES (Optical Emission Spectroscopy) and Langmuir probe. Plasma characteristics were modeled by a simple electric field analysis and fluid plasma modeling. Discharge shapes by a continuous dc and bipolar pulsed dc were different as a dome-type and a vertical column-type at the cathode. From OES, the intensity of 811.5 nm wavelength, the one of the main peaks of Ar, decreased to about 43% from a continuous dc to 100 kHz. For increasing from 100 kHz to 250 kHz, the intensity of 811.5 nm wavelength also decreased by 46%. The electron density decreased by 74% and the electron temperature increased by 36% at the specific position due to the smaller and denser discharge shape for increasing pulse frequency. Through the numerical analysis, the negative glow shape of a continuous dc were similar to the electric potential distribution by FEM (Finite Element Method). For the bipolar pulsed dc, we found that the electron temperature increased to maximum 10 eV due to the voltage spikes by the fast electron acceleration generated in pre-sheath. This may induce the electrons and ions from plasma to increase the energetic substrate bombardment for the dense thin film growth.

양방향 펄스전원을 이용한 NO 가스의 방전처리 (Discharge Processes of NO Gas Using Bidirectional Pulsed Voltage)

  • 주홍진;박정호;심재학;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1682-1684
    • /
    • 2001
  • In removing the flue-gas using electrical discharge method, it is important to dissociate or ionize the atoms and molecules by the collisions with energetic electrons and it produces the radicals that are used to decompose the pollutants. For that purpose, a bidirectional pulsed voltage is used to produce lots of energetic electrons efficiently and increase the power efficiency. The simulation is performed with changing the pulsewidth under the fixed applied voltage. The particle-mesh model coupling the NGP(nearest-grid-point) to FEM(finite element method) is used to simulate the behavior of electrons and the spatio-temporal variation of the electric field for the streamer in discharge tube.

  • PDF