• Title/Summary/Keyword: Pulsed electric discharge

Search Result 38, Processing Time 0.026 seconds

A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment (고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구)

  • Lee, Min-Gyu;Chung, Geun-Sik;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Discharge characteristics of FFL as applied voltage variation (인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

A Study on Operation Characteristics of Three Electrode Trigger Gap Switch (3전극 트리거 갭 스위치 동작특성에 관한 연구)

  • Hong, Tae-Yun;Han, Sang-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

DeNOx modeling in $N_{2}/O_{2}$ gas by pulsed corona discharge ($N_{2}/O_{2}$ 혼합가스에서 펄스코로나 방전을 이용한 NOx 제거 모델링에 관한 연구)

  • Park, Kwang-Seo;Lee, Hyoung-Sang;Chun, Bae-Hyeock;Shin, Hyun-Ho;Yoon, Woong-Sup;Chun, Kwang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.117-128
    • /
    • 1999
  • The removal of nitrogen oxides(NOx) from $N_{2}/O_{2}$ gas using a pulsed corona discharge was investigated as a function of the reduced electric field(E/N) and the energy density(J/L). A kinetic model was developed to characterize the chemical reactions taking place in a pulsed corona discharge reactor. The model calculates the fractional concentrations of radical species at each pulse-on period and utilizes the radicals to remove NOx for the subsequent pulse-off period. Electron collision reaction data are calculated using ELENDIF program to solve Boltzmann equation for electron energy distribution function, and the subsequent chemical reactions are calculated using CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement with the experimental data, and predicts the formation of other species such as $NO_{2}$, $O_{3}$ and $N_{2}O$.

  • PDF

Low-Pressure Mercury-Free Fluorescent Lamp for General Lighting

  • Jinno, Masafumi;Lee, Jong-Chan;Motomural, Hideki;Aono, Masaharu;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper we report on development of our original mercury-less fluorescent lamps for general lighting. These new-type lamps have multi-pairs of electrodes to maintain multi-discharge paths and to keep positive column diffused state. The omission characteristics oft the lamps were investigated. These discharge lamps were operated by pulsed discharge. By using multi-pairs of electrodes for xenon pulsed discharge fluorescent lamps, higher intensity of luminance was obtained than the conventional type of lamps using single pair of electrodes. Recently this type of lamp achieved over $9000\;cd/m^2$ and 50 lm/W.

  • PDF

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

Load Transfer on Pulsed Power Discharge Anchors (펄스방전 확공형 앵커의 하중전이에 관한 연구)

  • Kim, Sung-Kyu;Kim, Nak-Kyung;Kim, Jae-Won;Joo, Yong-Sun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF

Observation of Plasma Shape by Continuous dc and Pulsed dc (직류 방전과 펄스 직류 방전에 의한 플라즈마 형상 관찰)

  • Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.3
    • /
    • pp.133-138
    • /
    • 2009
  • Effects of bipolar pulse driving frequency between 50 kHz and 250 kHz on the discharge shapes were analyzed by measuring plasma characteristics by OES (Optical Emission Spectroscopy) and Langmuir probe. Plasma characteristics were modeled by a simple electric field analysis and fluid plasma modeling. Discharge shapes by a continuous dc and bipolar pulsed dc were different as a dome-type and a vertical column-type at the cathode. From OES, the intensity of 811.5 nm wavelength, the one of the main peaks of Ar, decreased to about 43% from a continuous dc to 100 kHz. For increasing from 100 kHz to 250 kHz, the intensity of 811.5 nm wavelength also decreased by 46%. The electron density decreased by 74% and the electron temperature increased by 36% at the specific position due to the smaller and denser discharge shape for increasing pulse frequency. Through the numerical analysis, the negative glow shape of a continuous dc were similar to the electric potential distribution by FEM (Finite Element Method). For the bipolar pulsed dc, we found that the electron temperature increased to maximum 10 eV due to the voltage spikes by the fast electron acceleration generated in pre-sheath. This may induce the electrons and ions from plasma to increase the energetic substrate bombardment for the dense thin film growth.

Discharge Processes of NO Gas Using Bidirectional Pulsed Voltage (양방향 펄스전원을 이용한 NO 가스의 방전처리)

  • Ju, Heung-Jin;Park, Jeong-Ho;Shim, Jae-Hak;Ko, Kwang-Cheol;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1682-1684
    • /
    • 2001
  • In removing the flue-gas using electrical discharge method, it is important to dissociate or ionize the atoms and molecules by the collisions with energetic electrons and it produces the radicals that are used to decompose the pollutants. For that purpose, a bidirectional pulsed voltage is used to produce lots of energetic electrons efficiently and increase the power efficiency. The simulation is performed with changing the pulsewidth under the fixed applied voltage. The particle-mesh model coupling the NGP(nearest-grid-point) to FEM(finite element method) is used to simulate the behavior of electrons and the spatio-temporal variation of the electric field for the streamer in discharge tube.

  • PDF