• 제목/요약/키워드: Pulsed corona discharges

검색결과 5건 처리시간 0.018초

수중 펄스코로나 방전에 의한 메틸오렌지 제거 특성 (Degradation of methyl orange by pulsed corona discharges in aqueous solution)

  • 이현돈;김종오;김형갑;정재우
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2012
  • A laboratory experiment on methyl orange degradation in pulsed corona discharges was carried out. Effects of operating parameters such as applied voltage, pH, conductivity and initial concentration on methyl orange degradation were investigated. The pulsed corona discharges decreased the pH of solution and increased conductivity, probably due to products generated from methyl orange degradation by corona discharges. The decrease of initial pH enhanced the methyl orange degradation. The methyl orange degradation was fastest in $100{\mu}S/cm$ conductivity solution, followed by 50 and $200{\mu}S/cm$, indicating that $100{\mu}S/cm$ is the most favorable in the aspect of radical generation among the experimented conditions. The methyl orange of initial concentration from 20 to 60mg/L was effectively degraded in pulsed corona discharges. The lower initial concentration of methyl orange, the faster degradation was observed.

펄스 코로나 방전에 의한 액체상 페놀 전환 특성 (Phenol Conversion Properties in Aqueous Solution by Pulsed Corona Discharge)

  • 이현돈;정재우;조무현
    • 대한환경공학회지
    • /
    • 제29권1호
    • /
    • pp.40-46
    • /
    • 2007
  • 펄스 코로나 방전에 의한 페놀 수용액 처리 특성에 관해 실험실 규모 실험을 수행하였으며 페놀 전환에 미치는 인가전압, 유입 산소, 전극 구조의 영향을 관찰하였다. 액체상 내에서 일어나는 방전은 전류 흐름으로부터 용액으로의 열전달에 의해 용액의 온도를 상승시키고 페놀을 분해하여 각종 유기산을 생성시킴으로써 pH를 감소시키며, 하전입자의 생성과 유기산 생성으로 인해 용액의 전도도 값을 증가시키는 것으로 나타났다. 외부로부터 공급되는 산소는 용액 내에서 오존 생성과 용해를 통해 OH 라디칼을 생성시킴으로써 페놀의 분해속도를 증가시키는 것으로 나타났다. 방전이 액체상 및 기체상에서 동시에 발생하는 series type의 전극 구조를 사용하면 기체상에서 높은 농도의 오존을 생성시킬 수 있으므로 액체상에서만 방전이 발생하는 reference type의 전극 구조에서보다 높은 페놀 분해 속도와 TOC 제거 효율을 얻을 수 있는 것으로 나타났다.

펄스 코로나 방전에 의한 페놀 분해에 미치는 운전변수의 영향 (Effects of Operating Parameters on Phenol Degradation by Pulsed Corona Discharges in Aqueous Solutions)

  • 정재우;문지훈;박은옥
    • 대한환경공학회지
    • /
    • 제32권1호
    • /
    • pp.79-86
    • /
    • 2010
  • 펄스 코로나 방전에서 인가전압, 용액 전도도, 전극 재질, 철염 주입 등의 운전변수가 페놀 분해에 미치는 영향에 관해 실험실 규모의 실험을 수행하였다. 인가전압이 증가할수록 높은 에너지를 가진 전자들에 의한 물 분자의 충돌분해 반응에 의한 OH 라디칼 생성량이 증가하므로 페놀 분해 속도를 증가시키며 실험된 조건에서의 용액 전도도 증가는 용액을 통한 전기장 강도를 감소시켜 페놀 분해 속도를 낮추는 것으로 나타났다. 방전 반응기로 주입된 철염($FeSO_4$)은 방전에 의해 생성된 과산화수소와 펜톤 유사 반응을 통해 OH 라디칼을 생성시켜 페놀 분해를 증가시키는 것으로 나타났다. 펄스 코로나 방전에 의한 페놀 분해의 중간 생성물질로 catechol과 hydroquinone이 검출되었으며 분석을 수행하지는 않았으나 유기산의 생성으로 인해 pH가 감소되고 전도도가 증가하는 현상이 관찰되었다. 철염이 주입된 조건에서 백금 전극은 3가 철이온($Fe^{3+}$)을 2가 철이온($Fe^{2+}$)으로 환원시킴으로써 페놀 분해 속도를 증가시키는 것으로 나타났다. 산제일철($FeSO_4$) 0.5 mM이 주입된 조건에서 약 230 kJ의 방전 에너지가 유입될 때 거의 모든 페놀이 분해되었으며 약 29%의 총유기탄소(TOC) 제거효율을 얻을 수 있었다.

수중 펄스코로나 방전을 중첩한 고효율 강전해수 발생장치 (A High Efficiency Electrolytic Cell by Superposing Pulsed Corona Discharge in Water)

  • 이재용;김진규;정성진;박승록;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.79-85
    • /
    • 2001
  • A conventional electrolyzing cell has been made by an ion exchange membrane inbetween parallel plate electrodes. A low dc voltage is applied to the electrodes for electrolyzing and the efficiency is remained in low. in this study, a novel electrolyzing cell with a pair of slit-type third electrodes installed inbetween parallel plate electrodes has been proposed and investigated experimentally. And pulse power wa supplied to between each electrodes. This slit type of third electrodes can concentrate the strong electric fields at the every its edges to accelerate the electrolyzing powers, and to generate oxygen bubble discharges for generating oxidants. And moreover the slits eliminate the space charge limiting action and the temperature of the water by leaking out through the slits from electrolyzing region to outside of the main electrode region. As a result, it was found that a strong electorzed water of pH 2.8 and pH 10.5 and oxidants dissolved water of 1 [ppm] in acidic water were obtained with a tap water fed at the electric current of 2 [A], which however were several times higher oxidant and ion concentration quantity compared with the conventional cell.

  • PDF

펄스 플라스마 반응기에 대한 임피던스 및 누설 인덕턴스 분석 (Analysis of Impedance and Stray Inductance for Pulsed Plasma Reactor)

  • 최영욱;이홍식;임근희;김태희;김종화;장길홍;신완호;송영훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.253-260
    • /
    • 1999
  • In this paper, the impedance characteristic of wire-plate pulsed plasma reactor was investigated by experiment. The experiment have carried out under the several conditions of voltage, wire length and wire-plate distance. The impedance of reactor wad decreased with increasing voltage and wire length. The nature of discharge in reactor was changed from streamer corona to spark with increasing incident energy, from which we understood the critical energy density between the two discharges. Fromthis experiment, we proposed the method for the impedance matching between pulse generator and pulsed plasma reactor. Additionally, we succeeded in the analysis ofstray inductance of 0.5MW reactor using EMTP (ElectroMagnetic Transients Program). This means that EMTP is also useful for the analysis of inevitable stray inductance of forthcoming a large scale reactor.

  • PDF