• Title/Summary/Keyword: Pulsed Nd:YAG

Search Result 277, Processing Time 0.026 seconds

Sterilization of Escherichia coli Based on Nd: YAG Resonator with a Pulsed Xenon Flashlamp

  • Kim, Hee-Je;Kim, Dong-Jo;Hong, Ji-Tae;Xu, Guo-Cheng;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.275-279
    • /
    • 2011
  • Sterilization of Escherichia coli (E. coli) is examined using a unique pulsed ultra-violet (UV) elliptical reactor based on Nd:YAG laser resonator, UV radiation from a pulsed xenon flashlamp. The light from the discharge has a broadband emission spectrum extending from the UV to the infrared region with a rich UV contained. Sterilization method by using the UV light is fast, environment-friendly and it does not cause secondary pollution. A Nd:YAG laser resonator having elliptical shape has advantage of concentrating the radiation of the UV light at two foci as the quart sleeve filled with E. coli. The primary objective of this research is to determine the important parameters such as pulse per second (pps), the applied voltage for sterilizing E. coli by using an UV elliptical reactor. From the experiment result, the sterilization effect of UV elliptical reactor is better than that of UV cylindrical reactor, and it can be 99.9% of sterilization at 800V regardless of the pps within 10 minutes.

The Removal of Mucocele and Ranula using the Pulsed Nd:YAG Laser (펄스형 Nd:YAG 레이저를 이용한 점액류와 하마종의 치료)

  • Suh, Bong-Jik;Chang, Kee-Wan;Shin, Keum-Back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.403-411
    • /
    • 2000
  • The authors experienced a non-painful, elevated, dome-shaped lesion on lower lip in Korean male of 22-year-old and a non-painful, elevated, dome-shape lesion on left side of mouth floor in Korean female of 36-year-old. And diagnosed the lesions as a mucocele and a ranula respectively, based on the comprehensive evaluation of data obtained from history taking, clinical and radiologic examination and histopathological findings. In these cases, the authors removed mucocele and ranula using the pulsed Nd:YAG laser with advantage of good hemostatic effect, and so we could minimize improper tissue destruction during operation. The excisional wounds of lower lip and mouth floor had a good healing process without any symptom of pain and any signs of bleeding and infection.

  • PDF

A Study on the control of output power and pulse repetition rate in pulsed Nd:YAG laser (펄스형 Nd:YAG 레이저의 출력 에너지 및 펄스 반복률 제어에 관한 연구)

  • Park, K.R.;Kim, B.G.;Moon, D.S.;Hong, J.H.;Kim, W.Y.;Kang, U.;Kim, H.J.;Cho, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.74-77
    • /
    • 2000
  • A pulsed Nd:YAG laser has been used in a wide variety of fields : measuring, material processing and so on. In a material processing, it is very important to control the laser energy density. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, pulsed Nd:YAG laser system was designed and manufactured to control the laser output usefully and easily. This system adopted the sequential charge and discharge circuit is controlled by 80196 micro- processor. As a result, it is found that laser output is controlled minutely by changing laser input and pulse repetition rate, and usefully by using 80196 microprocessor.

  • PDF

Characteristics of Output Energy and Optical Parameters in Welding of Braun Tubes by Pulsed Nd:YAG Laser (펄스 Nd:YAG 레이저에 의한 브라운관 부품의 용접시 빔의 출력특성과 광학변수)

  • Kim Jong-Do;Ha Seung-Hyup
    • Laser Solutions
    • /
    • v.8 no.1
    • /
    • pp.27-37
    • /
    • 2005
  • During laser spot welding of the braun tube electron gun, phenomena such as serious spattering and oxidative reaction, etc. were occurred. The spatter occurred from weld pool affects the braun tube, namely it blocks up a very small hole on the shadow mask and causes short circuit between two poles of the electron gun. We guessed that high power density and oxidative reaction are main sources of these problems. So, we studied to prevent and to reduce spatter occurring in spot welding of the braun tube electron gun using pulsed Nd:YAG laser. The characteristics of laser output power was estimated, and the loss of laser energy by optical parameter and spatter was measured by powermeter. The effects of welding parameters, laser defocused distance and incident angle, were investigated on the shape and penetration depth of the laser welded bead in flare and flange joints. From these results, the laser peak power was a major factor to control penetration depth and to occur spatter. It was found that the losses of laser energy by optic parameter and sticked spatter affect seriously laser weldability of thin sheets.

  • PDF

The high repetition operating characteristics of pulsed Nd:YAG laser by parallel mesh and alternating charge-discharge system (병렬 메쉬 및 교번 충.방전 방식에 의한 펄스형 Nd:YAG 레이저의 고반복 동작특성에 관한 연구)

  • Park, K.R.;Kim, B.G.;Hong, J.H.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1060-1062
    • /
    • 1999
  • Pulsed Nd:YAG laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. And the parallel mesh is added to increase laser output power. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition, we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the parallel mesh and the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 10pps to 110pps by the step of 20pps at 1000V and 1200V, it is found that the laser efficiency decreases but the laser output power increases about 5W at each step.

  • PDF

A STUDY OF ANALGESIC EFFECT ON PULP INDUCED BY PULSED Nd : YAG LASER (Pulsed Nd ; YGA 레이저의 치수마취효과에 관한 연구)

  • Kim, Do-Hyeong;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.301-312
    • /
    • 1997
  • The purpose of this study was to evaluate the analgesic effect on pulp induced by pulsed Nd : YAG laser according to the power density, irradiated time and the method of application (Non-contact vs contact) in vivo. Experiments were carried out on 90 volunteers who have sound 4 canines. Each canine was grouped by the intensity and the time of irradiation of pulsed Nd : YAG laser was measured. Mean EPT response(units) was measured at 5 min, 30 min, and 60 min after irradiation with various intensity(1.5-3W, 15-30Hz), irradiated time (1.5min, 3min), and application method (Non-contact and contact). The results were as follows: 1. 5 minutes after irradiation, the mean EPT response(units) was increased by 32 % in the non-contact method and by 35% in the contact method of application. Which showed significant difference in mean EPT response(units) compared to not-lased canine in each groups(P<0.05). 2. The mean EPT response(units) with irradiating condition according to the various laser intensity, and the irradiation time stastically did not show significant difference in each groups as time elapsed. 3. There was no significant difference between the non-contact and contact method in the mean EPT response(units). 4. The mean EPT response(units) returned to the baseline value within 30 miuntes. In regard to the above results, the analgesic effect on pulp induced by pulsed Nd : YAG laser resulted a slight increase of pulpal pain threshold, but it was not as high as to replace the role of drug analgesia as whole. This technique can be used for inducing pulpal analgesia as adjunct to other pain control methods and is needed to develop better analgesic effects.

  • PDF

Nd:YAG laser firmware Design under RTOS operation (RTOS(Real Time Operation System) 환경하의 Nd:YAG 레이저 Firmware 설계)

  • Kim, B.G.;Kim, W.Y.;Park, G.R.;Moon, D.S.;Hong, J.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2107-2109
    • /
    • 2000
  • A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate This system is controlled by microprocessor and allows to replace an expensive condenser for high frequency to cheap one for low frequency. In addition, The microcontroller monitors the flow of cooling water, short circuit. and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now.

  • PDF

A study on the pure Al weldability using a pulsed Nd : YAG laser (펄스형 Nd:YAG 레이저를 이용한 Al의 용접 특성연구)

  • 김덕현
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.52-61
    • /
    • 1993
  • Laser welding of ASTM no. 1060 Al plate with a pulsed Nd: YAG laser of 200W average power was performed for end capping of KMRR nuclear fuel elements In this research, we performed basic welding experiments. Firstly, laser output parameters which affect laser welding parameters were studied by changing laser input parameters for effective welding of 1060 Al plates. We found that laser power density and pulse energy are important parameters for smooth bead shape. Secondly, welding parameters which affect weld width-to-depth ratio were studied by changing power density and pulse energy, shielding gas, and defocusing. We found that power density must be higher than 0.3 Mw/cm$^{2}$ pulse energy must be higer than 3 J. travel speed must not exceed 200mm/sec, laser focus must be existed beneath 2-3mm from plate surface and helium is proper shielding gas. Thirdly, we studied the weld defects of Al-1060 such as crack and porosity in lap-joint welding. We designed new welding geometry for crack free welding of Al-1060 plates, and obtained crack free weldment but with lack of fusion. However, with Ti, Zr grain refiner elements, we can weld Al plates without solidification hot crack. Finally, we studied the origin of porosity by changing shielding gas. And we found that porosity was resulted from entrapment of shielding gas by the collapsing keyhole.

  • PDF

The high repetition operating characteristics of pulsed Nd:YAG laser by alternating charge-discharge system (펄스형 Nd:YAG 레이저의 교번 충.방전 방식에 의한 고반복 동작특성)

  • Kim, W.Y.;Park, K.R.;Kim, B.G.;Hong, J.H.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2204-2206
    • /
    • 1999
  • Pulsed Nd:YAC laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition. we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 30pps to 120pps by the step of 30pps at 1200V, it is found that the laser efficiency decreases but the laser output power increases about 6W at each step.

  • PDF