• Title/Summary/Keyword: Pulsed Current

Search Result 496, Processing Time 0.028 seconds

Pulsed-Power System for Leachate Treatment Applications

  • Jang, Sung-Roc;Ryoo, Hong-Je;Ok, Seung-Bok
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.612-619
    • /
    • 2011
  • This paper presents a water treatment system for leachate from sewage-filled ground that uses a pulsed-power modulator developed based on semiconductor switches in order to realize a long life, a high repetition rate, and a fast rising time. The specifications of the developed pulsed-power modulator are the pulsed output voltage, the output current, the pulse repetition rate (PRR), the pulse width, and an average output power of $60\;kV_{max}$, $300\;A_{max}$, 3000, $50\;{\mu}s$, and 15 kW, respectively. The pulsed-power water treatment system was introduced and analyzed using an equivalent electrical circuit model to optimize the output voltage waveform. The experimental results verify that the proposed water treatment system can be effectively used for industrial applications.

펄스 GMA 위빙 용접에서 그루브형상에 따른 아크특성에 관한 연구 (Influence of the Groove Angle on Arc Characteristics in Pulsed GMA Weaving Welding)

  • 최광덕;조원익;김철희;나석주
    • Journal of Welding and Joining
    • /
    • 제27권4호
    • /
    • pp.67-72
    • /
    • 2009
  • In this paper, arc characteristics of V groove joints using pulsed GMA welding were found out. The bevel angles of $22.5^{\circ}$ and $30.0^{\circ}$ were chose to make the V groove configuration with the groove angles of $45^{\circ}$ and $60.0^{\circ}$, respectively. In the experiment, the arc current waveform measurement and the high speed photography were taken to investigate the arc characteristics for a single-beveled asymmetric workpiece. Consequently, the welding current was changed abnormally around the edge of groove. As the arc moved close to the groove face, the welding current was increased rapidly because the welding arc was affected by the inclined surface. Also the welding current waveforms were measured for the double-sided symmetric workpiece to verify the previous measurements for the single-beveled workpiece, and similar current waveforms were found.

펄스 와전류를 이용한 알루미늄 두께 평가 (Thickness Evaluation of the Aluminum Using Pulsed Eddy Current)

  • 이정기;서동만;이승석
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.15-19
    • /
    • 2005
  • 일반적인 와전류 검사는 단일 주파수 또는 매우 협소한 주파수 대역을 가지는 정현적 신호 사용하며, 알루미늄과 같은 도체에서 피로 균열 같은 결함을 검출하는데 사용되고 있다. 이에 반하여 펄스 와전류는 아주 넓은 주파수 대역폭을 가지는 펄스 신호를 사용한다. 이것은 여러 주파수를 동시에 사용하는 다중 주파수 와전류 검사를 한번에 수행할 수 있도록 하며, 일상적인 와전류 검사에 비하여 침투 깊이를 더 깊게 할 수 있다는 장점이 있다. 본 연구에서는 부식 또는 침식 등에 의한 금속 손실을 평가하기 위한 펄스 와전류 장치를 개발하였다. 개발된 장비는 최대 40 V의 구형 펄스를 발생시키는 펄스 발생기, 수신된 신호를 52 dB까지 증폭하는 증폭기, 16 bit 20MHz의 A/D 변환기, 윈도우 프로그램으로 운영되는 산업용 개인 컴퓨터로 구성하였다. 펄스 와전류 탐촉자는 구동 코일 안에 검출 코일을 삽입한 pancake 형태로 설계 제작하였다. 검출 코일의 출력 신호는 구동 코일에 전압을 끊을 때 갑자기 증가하고 신호의 후반부는 시간에 따라 지수적으로 감소하였으며, 감쇠율을 나타내는 지수 값은 알루미늄 두께가 두꺼울수록 증가하였다.

펄스전류인가가 황동-알루미나 나노복합도금층의 경도에 미치는 영향 (Effect of Pulse Plating on Hardness of Brass-Alumina Nanocomposite)

  • 오영주;안재우;안종관;이만승
    • 한국표면공학회지
    • /
    • 제35권3호
    • /
    • pp.158-164
    • /
    • 2002
  • Nanocomposites consisting of a nanocrystalline brass matrix (grain size ; 20-100nm) with sub-micron sized Al2O3 particles (60-200nm) were prepared by pulsed current electrodeposition. The microhardness of the nanocomposite with a grain size of 90-100nm was approximately 1.7 times higher than that of a comparable electrodeposit with no particles. However, significant variations in microhardness were not observed between the nanocomposites with grain sizes of 20 nm and the comparable electrodeposit.

고전압.대전류폴스파워를 이용한 암반발파 모의 기술개발 (Application of Pulsed Power with the High Voltage & current for Rock Fragmentation)

  • 서길수;김영배;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1592-1595
    • /
    • 1998
  • The rock fragmentation system with a capacitor bank, switching device, cable and blasting electrode are described. Utilization of the chemical energy from the electrolyte and the pseudospark with a large current capacity suggested the commercialization possibility of the rock fragmentation system. The vibration and noise level of the pulsed blasting is acceptable in the most ground breaking. And also the electromagnetic force produced by the inductor is introduced for the rock fragmentation.

  • PDF

Electromigration Characteristics in PSG/SiO$_2$ Passivated Al-l%Si Thin Film Interconnections

  • Kim, Jin-Young
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.39-44
    • /
    • 2003
  • Recent ULSI and multilevel structure trends in microelectronic devices minimize the line width down to a quarter micron and below, which results in the high current densities in thin film interconnections. Under high current densities, an EM(electromigration) induced failure becomes one of the critical problems in a microelectronic device. This study is to improve thin film interconnection materials by investigating the EM characteristics in PSG(phosphosilicate glass)/SiO$_2$ passivated Al-l%Si thin film interconnections. Straight line patterns, wide and narrow link type patterns, and meander type patterns, etc. were fabricated by a standard photholithography process. The main results are as follows. The current crowding effects result in the decrease of the lifetime in thin film interconnections. The electric field effects accelerate the decrease of lifetime in the double-layered thin film interconnections. The lifetime of interconnections also depends upon the current conditions of P.D.C.(pulsed direct current) frequencies applied at the same duty factor.

  • PDF

Investigation of Diazepam by Pulsed Rotation Voltammetry

  • Blaedel, W.J.;Hahn, Young-Hee
    • Archives of Pharmacal Research
    • /
    • 제2권2호
    • /
    • pp.111-114
    • /
    • 1979
  • Diazepam was investigated in aqueous buffer media using pulsed rotation voltammetry. The dependence of half-wave potentials on pH indicated a two proton involvement in a two electron transfer reduction in the pH range 3-10. Dizaepam at micromolar concentration levels may be determined by measurement of the limiting difference current.

  • PDF

Dual Core Differential Pulsed Eddy Current Probe to Detect the Wall Thickness Variation in an Insulated Stainless Steel Pipe

  • Angani, C.S.;Park, D.G.;Kim, C.G.;Kollu, P.;Cheong, Y.M.
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.204-208
    • /
    • 2010
  • Local wall thinning in pipelines affects the structural integrity of industries like nuclear power plants (NPPs). In the present study, a pulsed eddy current (PEC) differential probe with two excitation coils and two Hall-sensors was fabricated to measure the wall thinning in insulated pipelines. A stainless steel test sample was prepared with a thickness that varied from 1 mm to 5 mm and was laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe were driven by a rectangular current pulse, the difference of signals from two Hall-sensors was measured as the resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The peak value increased as the thickness of the test sample increased. The results were measured at different insulation thicknesses on the sample. Results show that the differential PEC probe has the potential to detect wall thinning in an insulated NPP pipelines.

펄스전류활성 소결 공정을 이용한 Ni 함량변화에 따른 WC 소재의 특성평가 (Characteristic Evaluation of WC Hard Materials According to Ni Content Variation by a Pulsed Current Activated Sintering Process)

  • 박현국
    • 한국재료학회지
    • /
    • 제30권12호
    • /
    • pp.672-677
    • /
    • 2020
  • Expensive PCBN or ceramic cutting tools are used for the processing of difficult-to-cut materials such as Ti and Ni alloy materials. These tools have a problem of breaking easily due to their high hardness but low fracture toughness. To solve this problem, cutting tools that form various coating layers are used in low-cost WC-Co hard material tools, and researches on various tool materials are being conducted. In this study, WC-5, 10, and 15 wt%Ni hard materials for difficult-to-cut cutting materials are densified using horizontal ball milled WC-Ni powders and pulsed current activated sintering method (PCAS method). Each PCASed WC-Ni hard materials are almost completely dense, with a relative density of up to 99.7 ~ 99.9 %, after the simultaneous application of pressure of 60 MPa and electric current for 2 min; process involves almost no change in the grain size. The average grain sizes of WC and Ni for WC-5, 10, and 15 wt%Ni hard materials are about 1.09 ~ 1.29 and 0.31 ~ 0.51 µm, respectively. Vickers hardness and fracture toughness of WC-5, 10, and 15 wt%Ni hard materials are about 1,923 ~ 1,788 kg/mm2 and 13.2 ~ 14.3 MPa.m1/2, respectively. Microstructure and phase analyses of PCASed WC-Ni hard materials are performed.