• 제목/요약/키워드: Pulse-on Time

Search Result 1,713, Processing Time 0.039 seconds

The Method of Reducing Echo Time in 3D Time-of-flight Angiography

  • Park, Sung-Hong;Park, Jung-Il;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.367-369
    • /
    • 2002
  • We have designed ramp profile excitation pulse based on the Shinnar-Le Roux (SLR) algorithm. The algorithm provides many advantages to pulse designers. The first advantage is the freedom of deciding the amplitudes, frequencies, and ripple sizes of stopband, passband, and transition band of pulse profile. The second advantage is the freedom of deciding the pulse phase, more specifically, minimum phase, linear phase, maximum phase, and any phase between them. The minimum phase pulse is the best choice in the case of 3D TOF, because it minimizes the echo time, which implies the best image quality in the same MR examination condition. In addition, the half echo technique is slightly modified in our case. In general, using the half echo technique means that the acquired data size is half and the rest part can be filled with complex conjugate of acquired data. But in our case, the echo center is just shifted to left, which implies the reduction of echo time, and the acquired data size is the same as the one without using the half echo technique. In this case, the increase of right part of data leads to improvement of the resolution and the decrease of left part of data leads to decrease of signal to noise ratio. Since in the case of 3D TOF, the signal to noise ratio is sufficiently high and the resolution is more important than signal to noise ratio, the proposed method appears to be significantly affective and gives rise to the improved high resolution angiograms.

  • PDF

Spectral Analysis of Heart Rate Variability in ECG and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • Kim NagHwan;Lee EunSil;Min HongKi;Lee EungHyuk;Hong SeungHong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • The analysis of power spectrum based on linear AR model is applied widely to quantize the response of autonomic nerve noninvasively, In this paper, we estimate the power spectrum density for heartrate variability of the electrocadiogram and pulse wave for short term data(less than two minute), The time series of heart rate variability is obtained from the time interval(RRI, PPI) between the feature point of the electrocadiogram and pulse wave for normal person, The generated time series reconstructed into new time series through polynomial interpolation to apply to the AR mode. The power spectrum density for AR model is calculated by Burg algorithm, After applying AR model, the power spectrum density for heart rate variability of the electrocadiogram and the pulse wave is shown smooth spectrum power at the region of low frequence and high frequence, and that the power spectrum density of electrocadiogram and pulse wave has similar form for same subject.

  • PDF

A numerical study on the characteristics of a thermal mass air flow sensor with periodic heating pulses (주기 발열 파형을 이용한 열식 질량 유량계의 특성에 관한 수치적 연구)

  • Jeon, Hong-Kyu;Oh, Dong-Wook;Park, Byung-Kyu;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2482-2487
    • /
    • 2007
  • Numerical simulations are conducted for the analysis of a thermal mass air flow sensor with periodic heating pulses on silicon-nitride ($Si_3N_4$) thin membrane structure. This study aims to find the locations of temperature sensors on the thin membrane and the heating pulse conditions, that the higher sensitivity can be achieved, for the development of a MEMS fabricated mass air flow sensor which is driven in periodic heating pulse. The simulations, thus, focus on the membrane temperature profile according to variation of the flow velocity, heating duration time and imposed power. The flow velocity of the simulations is ranging from 3 m/s to 35 m/s, heating duration time from 1 ms to 3 ms and imposed power from 50 mW to 90 mW. The corresponding Reynolds numbers vary from 1000 to 10000.

  • PDF

Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity (맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발)

  • Choi, Jung-Hyeon;Cho, Wook-Hyun;Park, Jun-Ho;Kim, Nam-Hoon;Seong, Hyang-Sook;Cho, Jong-Man
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

A Study on High-Repetition Rate Optical-Pulse for OTDM System Using Fiber Loop Mirror (OTDM 시스템을 위한 광섬유 루프 미러를 이용한 고 반복률 펄스 발생에 관한 연구)

  • 최원석;정찬권;김선엽;강영진
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.330-333
    • /
    • 2000
  • With the recent development of the ultrahigh-speed optical time division multiplexed system, high-repetition rate optical-pulse stream generation is necessary. This is different from conventional approaches, which use fiber or integrated waveguide delay line circuits. The high-repetition-rate optical-pulse multiplication phenomenon occurs when the optical pulse's spectral width is greater than the transfer bandwidth of the coupler used. From the analysis, the output repetition rate can be controlled by using fiber couplers with different equivalent transfer bandwidths. The pulse seperation spacing is controlled by number of cascaded coupler in optical loop mirror coupler scheme.

  • PDF

A New Strength Equations of Concrete by Ultrasonic Pulse Velocity Test (콘크리트의 초음파속도 시험식 제안)

  • Yoo Jae Eun;Park Song Chul;Kim Min Su;Kwon Young Wung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.619-622
    • /
    • 2005
  • This study concerns the new strength equation of concrete by ultrasonic pulse velocity test. There are not only few estimate strength equations of concrete by ultrasonic pulse velocity test, but also many problems to apply them because of time,. cost, easiness, structural damage, reliability and so on. For this study, there performed a series of test and proposed equations as follows; Linear: ${\Large f}_{ck}=-193.15+60.97Vp\;r^2=77.9\%$ Quadratic : ${\Large f}_{ck}=276.85-189.64Vp+33.22Vp^2\;r^2=80.3\%$ here, $f_{ck}$ : Estimated compressive strength of concrete by MPa Vp : Ultrasonic Pulse Velocity of concrete by km/sec

  • PDF

Development of Bidirectional Pulse Power Electrochemical Etching System for the Groove Manufacturing of the Dynamic Bearings (동압베어링의 그르브 가공용 양방향 펄스 파워 전해가공시스템 개발)

  • Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.224-229
    • /
    • 2005
  • This paper presents a bidirectional pulse power electrochemical etching system for groove manufacturing of the dynamic bearings. To manufacture the dynamic bearing for the groove, it is very important to consider the depth and roughness. If the precision of the groove is not exact, we can not get the desirable performance for the target of the dynamic bearing. To make the groove of bearing precise, we propose the method of electrochemical etching system. In order to design the depth and roughness exactly, the bidirectional pulse power converter is proposed. With the bidirectional pulse power converter, we obtain the condition and the parameters of converter such as frequency, duty ratio, time, temperature, velocity, pressure and so on. In this paper, we get the experimental results to verify the precise groove manufacturing.

A Study On PIN Pulse Pattern Optimization In The Space Vector Notation Using Pulse Frequency Modulation (펄스 주파수 변조 방법을 이용한 공간 벡터 PWM 펄스 패턴최적화 기법에 관한 연구)

  • Jeon, Hi-Jong;Son, Jin-Geun;Kim, Dong-Joon;Lee, Suck-Tae;Choi, Woo-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.307-312
    • /
    • 1994
  • In this investigation the PFM(Pulse Frequency Modulation} will be used for optimizing PWM inverter pulse pattern. In traditional the pulse frequency of PWM is kept const. But modulated PWM's frequency in this study, the sinusoidal inverter's performance should be improved. The PWM pulsepatterns are definitely controlled so that the time-integral function of the voltage vectors in the space vector notation may show a circular locus. Further, performance index will be minimized because of minimizing distortion of output current. Finally, we will implement itusingsingle-chip microprocessor.

  • PDF

A New Strength Equation of Concrete by Ultrasonic Pulse Velocity Test (초음파시험법에 의한 콘크리트의 강도 추정)

  • Yoo Jae-Eun;Park Song-Chul;Kim Min-Su;Kwon Young-Wung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.129-132
    • /
    • 2004
  • This study concerns the new strength equation of concrete by ultrasonic pulse velocity test. There are not only few estimate strength equations of concrete by ultrasonic pulse velocity test, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. For this study, there performed a series of test and proposed equations as follows; $$Linear\;:\;f_{kc}=65.43Vp-207.18\;r^2=80.8\%$$ $$Quadratic\;:\;f_{ck}=42.35Vp^2-250.71Vp+378.8\;r^2=83.7\%$$ here, fck : Estimated compressive strength of concrete by MPa Vp: Ultrasonic Pulse Velocity of concrete by km/sec.

  • PDF

A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer (피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구)

  • Kwon, Sung-Yul;Lee, Dong-Hoon;Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.