• Title/Summary/Keyword: Pulse-on Time

Search Result 1,713, Processing Time 0.036 seconds

Study on Classification of Pulse Condition of the Chronological Medical Practitioners (역대의가(歷代醫家)의 맥상(脈象) 분석(分類)에 대한 연구)

  • Park, Jae-Won;Kim, Byung-Soo;Kang, Jung-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1347-1353
    • /
    • 2008
  • Pulse condition is the essential division for conducting pulse diagnosis which is one of the most fundamental and important diagnostics in traditional Korean/Chinese medicine. We studied the pulse condition referred to classics of traditional medicine for a full understanding in present time and come to a conclusion like below. The reference to pulse condition was concluded to 'twenty four pulse conditions' which is the fundamental conception generally accepted in present age since it had first mentioned in "Huangdi Neijing" and after it had passed through "Nanjing", "pulse pattern identification-chapter of normal pulse"of Zhang Zhongjing and reached "Maijing"of Wang Shuhe. Although medical partitioners had different views to some extent about pulse condition, there were no significant differences in the main theoretical frame. Even though there had been a diversity of opinions on the classification of pulse-condition between various medical practitioners, the method of Dae-dae and the method of systematic endeavored by Zhou Xueting and Zhou Xuehai who were medical scholars in the Ch'ing dynasty have been a criterion for the classification of pulse-condition up to date. We were able to recognize that the change of pulse condition caused by pathological situation should be compared to physiological pulse condition for detecting the deficiency and excess by researching the analyzing methods of pulse condition mentioned in the "Lingshu", and the book of Hua Shou and Zhou Xuehai). To sum up, first normal pulse which is the physiological pulse condition should be a standard for detecting physiological pulse condition. Secondly, Zhou Xueting insisted that relaxed pulse should be a standard pulse condition for detecting normal pulse.

Assessment of transient vibrations of graphene oxide reinforced plates under pulse loads using finite strip method

  • Mirjavadi, Seyed Sajad;Forsat, Masoud;Barati, Mohammad Reza;Hamouda, A.M.S.
    • Computers and Concrete
    • /
    • v.25 no.6
    • /
    • pp.575-585
    • /
    • 2020
  • Based on a refined shear deformation finite strip, transient vibrations of graphene oxide powder (GOP) reinforced plates due to external pulse loads have been investigated. The plate has uniformly and linearly distributed GOPs inside material structure. Applied pulse loads have been selected as sinusoidal, linear and blast types. Such pulse loads result in transient vibrations of the GOP-reinforced plates which are not explored before. Finite strip method (FSM) has been performed for solving the equations of motion and then inverse Laplace transform technique has been employed to derive transient responses due to pulse loading. It is reported in this study that the transient responses of GOP-reinforced plates are dependent on GOP dispersions, GOP volume fraction, type of pulse loading, loading time and load locations.

Effect of Hematocrit Level on the Radial Pulse Wave (적혈구 용적이 요골 동맥의 맥파에 미치는 영향)

  • Ryu, Hyun-Hee;Jeon, Young-Ju;Kim, Jae-Uk;Lee, Hae-Jung;Woo, Young-Jae;Lee, Yu-Jung;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

Influence of 1st,2rd Sustain Pulse Width on AC-PDP Driving (Sustain 초단 펄스가 AC-PDP 의 구동에 미치는 영향)

  • Kim, S.S.;Cho, T.S.;Ahn, J.C.;Choi, M.C.;Jeoung, J.M.;Leem, J.Y.;Jeoung, Y.H.;Kim, T.Y.;Chong, M.W.;Choi, S.H.;Kim, S.B.;Ko, J.J.;Cho, K.S.;Choi, E.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.152-154
    • /
    • 2000
  • Electro_optical characteristics in AC-PDP are confined by a lots of parameters. especially driving pulse shape is very important to improve AC-PDP's luminosity and efficiency. In that experiment measure the luminosity, IR(Infra Red) peak value and response time as the increase of 1st, 2rd sustain pulse width. The VDS(Versatile Driving Simulator -developed by kwangwoon university-) was used to make driving pulse shape. It is found that IR response time after displacement current, Luminosity and IR peak value are changed on account of 1st,2rd sustain pulse width.

  • PDF

Effects of bee venom acupuncture on heart rate variability, pulse wave, and cerebral blood flow for types of Sasang Constitution (봉약침 자극이 사상체질별 건강인의 심박변이도, 맥파, 뇌혈류에 미치는 영향)

  • Lee, Sang-Min;Kim, Koo;Oh, Seung-Yun;Kwon, Young-Mi;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • 1. Objectives To evaluate effects of bee venom acupuncture on cardiovascular system and differences according to each constitution. 2. Methods Heart rate variability, pulse wave and the velocity of cerebral blood flow were measured before bee venom acupuncture(BVA), right after and after 30 minuets, had been applied to 20 subjects. 3. Results 1. BVA did not have effects on measurement variables of heart rate variability. 2. BVA had effects on pulse wave, showing total time, radial augmentation index up and height of percussion wave, time to percussion wave, sum of pulse pressure down. 3. BVA did not have effects on the cerebral blood flow velocity when considering not Sasang Constitution. 4. Considering Sasang Constitution, BVA demonstrates different responses in time to preincisura wave, mean blood flow velocity, peak systolic velocity and end diastolic velocity. 4.Conclusion From those results, the following conclusions are obtained. Cause BVA alters pulse wave and makes differences in the cerebral blood flow velocity according to Sasang Constitution. Various methods of BVA treatment are needed considering Sasang Constitution.

Sinusoidal A Study on the gain Stability of the Feedback Linear Pulse Amplifiers for Fast Pulse Input (금속펄스 선형증폭기의 빠른 입력펄스에 대한 이득안정도에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.3
    • /
    • pp.1-14
    • /
    • 1974
  • The gain stability of the nuclear pulse linear amplifiers with feedback for such a fast pulse input as the step voltage or the nuclear radiation detector pulse is analysed in detail. The expression is derived which describes the waveform at the anode circuit of the photomultiplier tube which is a part of the nuclear radiation detector. It is analysed and compared when the feedback amplifier has one and two time-constants. When these fast input pulse voltages are applied to the feedback amplifier, the effects of feedback in linearity and stability of the output voltage appear only after two or three rise-times of the amplifier, And it is proved that in order to reduce this limitation, the rise time of the feedback amplifier shou1d be less than the input pulse width. It is also shown that the above theory can be applied directly to the voltage-shunt feedback amplifier stages designed as the basic amplifier of the linear amplifier, and that the gain stability is more improved for the smaller input impedance of this amplifier stage.

  • PDF

Classification of Emotional States of Interest and Neutral Using Features from Pulse Wave Signal

  • Phongsuphap, Sukanya;Sopharak, Akara
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.682-685
    • /
    • 2004
  • This paper investigated a method for classifying emotional states by using pulse wave signal. It focused on finding effective features for emotional state classification. The emptional states considered here consisted of interest and neutral. Classification experiments utilized 65 and 60 samples of interest and neutral states respectively. We have investigated 19 features derived from pulse wave signals by using both time domain and frequency domain analysis methods with 2 classifiers of minimum distance (normalized Euclidean distanece) and ${\kappa}$-Nearest Neighbour. The Leave-one-out cross validation was used as an evaluation mehtod. Based on experimental results, the most efficient features were a combination of 4 features consisting of (i) the mean of the first differences of the smoothed pulse rate time series signal, (ii) the mean of absolute values of the second differences of thel normalized interbeat intervals, (iii) the root mean square successive difference, and (iv) the power in high frequency range in normalized unit, which provided 80.8% average accuracy with ${\kappa}$-Nearest Neighbour classifier.

  • PDF

Effects of Temperature Coefficients for Dielectric Constants on Thermoreflectances and Thermal Responses of Metal Thin Films Exposed to Ultrashort Pulse Laser Beams

  • Seungho Park
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Effects of temperature coefficients fur dielectric constants on transient reflectances and thermal responses have been investigated for a metal(gold) thin-film during ultrashort pulse laser heating. Heating processes are simulated using the conventional conduction model(parabolic one-step, POS), the parabolic tow-step model(PTS), the hyperbolic two-step model(HTS). Results fro the HTS model are very similar to those from the PTS model, since the laser heating time in this study is considerably greater than the electron relaxation time. PTS and HTS models, however, result in completely different temperature profiles from those obtained by the POS model due to slow electron-lattice interactions compared to laser pulse duration. Transient reflectances are directly estimated from the linear relationship between electron temperature and complex dielectric constants, while conventional approaches assume that the change in reflectances is proportional to that in temperatuer. Reflectances at the front surface vary considerably for various dielectric constants, while those at the rear surface remain unchanged relatively.

Damage Classification by Time Density Function of Ultrasonic Pulse Signal occurred at Tire (타이어에서 발생하는 초음파펄스신호의 시간밀도함수에 의한 손상 분별)

  • Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.291-296
    • /
    • 2015
  • The tire damage classification method is researched on the periodicity detection of ramdomness ultrasonic signals to occur at the driving vehicle tire. Setting method of adaptive threshold is proposed in order to valid pulse detection by tire damage in ultrasonic noise on the road and used low pass filter for decrease signal ramdomness as preprocessing. Time interval of detected pulse is setted the density function depend on the vehicle's speed and the method of tire damage detection is proposed that measuring the first peak's time of time density function.The result of time density function in case of one damage material, the first peak's time is measured within the error limit of tire's rotation period, 169.8ms and 97.9ms and 81.8ms, about the speed of 50km/h and 80km/h and 100km/h. In case of more than one damage material, the sum of each peak's time is measured within the error limit of tire's rotation period about the speed.

An Empirical Study on the Application of Lead-Acid Batteries to ESSs and Performance Improvement Methods

  • Jung, Hyun-Chul;Heo, Hoon
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1295-1304
    • /
    • 2015
  • In this paper, an approach to extend the life of lead-acid batteries through the elimination of sulfation with "rest time" using the pulse current of a conventional DPV (Differential Pulse Voltammetry) method is discussed. A new rest time without "0" current in "saw-tooth" pattern pulses is proposed to overcome the "0" current (blackout period), which is a shortcoming of DPV. This will enable the proposed method to be used in the loaded state. In the proposed approach, ESSs (Energy Storage Systems) were discharged for 5 h twice per day for 6 months on weekdays. To observe the changes in the lifespan of the systems, for the same period, the changes in the impedances of lead-acid batteries which were being charged e without charging and discharging were measure and compared. This study is focused on determining the effectiveness of lead-acid batteries as ESSs.