• Title/Summary/Keyword: Pulse width modulation(PWM)

Search Result 717, Processing Time 0.031 seconds

High-Frequency Induction Heating System Design of a PFM and PWM method using Fuzzy Control (퍼지제어기를 이용한 PFM 방식과 PWM방식의 고주파 유도가열기의 설계)

  • 장종승;설재훈;박종오;임영도
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.2
    • /
    • pp.43-49
    • /
    • 1998
  • This paper describes a phase-shift pulse-width modulation and pulse-frequency modulation seriesresonant high-frequency inverter using IGBT for the power control of high-frequency inductionheating using fuzzy, which is practically applied for 2 0- 5~0 0~~ ~in 1d uction-heating and meltingpov~er supply in industrial fields. The adaptive frequency tracking based phase-shifting PWMregillation scheme is presented in order to minimize switching losses. The trially-producedbreadboards using IGBT are succesfully demostrated and discussed.discussed.

  • PDF

A Novel Optimized PWM Method Based on the Selection of Pulse Position (펄스 위치 가변에 의한 취적 PWM 방식)

  • 최익;권순학;송중호;박귀태;황재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.8-14
    • /
    • 1998
  • This paper describes a novel real-time based optimal Pulse Width Modulation (PWM) method suitable for microprocessor-based PWM inverters. Optimal switching patterns minimizing the performance index corresponding to the distortion between the reference and the controlled output voltages are decided by on-line calculation using the microprocessor-implemented control system. To show the effectiveness of the proposed PWM scheme, digital simulation studies and experiments using a 16-bit single-chip microcontroller (Intel 80C196KC) are performed. The results obtained from these simulation studies and experiments show that the proposed PWM scheme has better performance than the other methods such as the natural PWM and the direct PWM.

A Study on The Resonant Frequency Following Control of Resonant Inverters (공진형 인버터의 공진 주파수 추종 제어에 관한 연구)

  • Kim, Nam-Jeung;Yo, Wan-Sik;Cho, Kyu-Min;In, Chi-Gak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1177-1181
    • /
    • 2000
  • Usually, in many applications. high frequency resonant inverters are used, and the PAM(Pulse Amplitude Modulation), PFM(Pulse Frequency Modulation) or PWM(Pulse Width Modulation) techniques are used to control the output power of resonant inverters. And the resonant inverters have to control the output frequency for the reliable operation under the variable load conditions. In this paper, a new switching scheme is proposed as a resonant frequency following control of resonant inverters. With the proposed method. it can be obtained that optimum resonant frequency and unity output displacement factor under the variable resonant frequency adaptively. The detail algorithm of the proposed switching scheme and its characteristics are discussed. And the veridity of the proposed method is confirmed with the experimental results.

  • PDF

Effects of Current Modulation Conditions on the Chromaticity of Phosphor Converted (PC) White LEDs

  • Kim, Seungtaek;Kim, Jongseok;Kim, Hyungtae;Kim, Yong-Kweon
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.449-456
    • /
    • 2012
  • For two well-known modulation methods, stepwise current modulation (SCM) and pulse width modulation (PWM), the effects of driving current modulation conditions on chromaticity were experimentally investigated in a white LED lighting system. For the experimental implementation of both SCM and PWM, a white LED lighting was fabricated using phosphor converted (PC) white light emitting diodes (LEDs) and a driving circuit module was developed. By using them, the variations of illuminance, color coordinates, and spectrum were evaluated under various forward current conditions. Through the analysis in color coordinates, yellow shift in SCM and blue shift in PWM were observed on chromaticity diagrams with increasing average driving current. In addition, in order to analyze color deviation quantitatively, color distance before and after current increase, and the correlated color temperature (CCT) were calculated. As a result, for the white LED lighting in both modulation conditions, the maximum difference in the calculated CCT was obtained close to 1000 K. It means that careful consideration is required to be taken in the design of illumination systems to avoid serious problems such industrial accidents.

Performance Improvement of BLDC Motor Speed Control Using Hybrid PWM Method (하이브리드 PWM 방식을 이용한 브러시리스 직류 전동기의 속도 제어 성능 향상)

  • 이동훈;오태석;전성구;김일환;남부희
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.7
    • /
    • pp.491-500
    • /
    • 2004
  • This paper considers a hybrid PWM(pulse width modulation) method which can be used in the brushless DC motor controller. Due to many disadvantages of bipolar PWM method, unipolar PWM method is mostly used in industrial field. In constant speed control application, the unipolar PWM method shows the good performance of speed control. But in the wide range of speed control application, it shows poor performance especially when deceleration is needed. So we propose the hybrid PWM method that utilizes both of bipolar and unipolar PWM methods according to the sign of the speed controller output. Simulation and experimental result show that the proposed method improves speed control performance of the brushless DC motor which is applied to the industrial sewing machines.

Performance Improvement of BLDC Motor Speed Control Using Hybrid PWM Method (하이브리드 PWM 방식을 이용한 브러시리스 직류 전동기의 속도 제어 성능 향상)

  • Lee, Dong-Hoon;Kim, Il-Hwan;Nam, Bu-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.19-21
    • /
    • 2004
  • This paper considers pulse width modulation (PWM) methods which are used in 3-phase brushless DC motor controller. Due to many disadvantages of bipolar PWM method, unipolar PWM method is mostly used in industrial field. In constant speed control application, the unipolar PWM method shows a good performance of speed control. But in the wide range of speed control application, it shows a poor performance especially when deceleration is needed. So we propose hybrid PWM method that utilizes two PWM methods according to the sign of speed controller output. The simulation and experimental result shows that the proposed method improves a speed control performance of the brushless DC motor which is applied to industrial sewing machines.

  • PDF

Analysis of the Phase Current Measurement Boundary of Three Shunt Sensing PWM Inverters and an Expansion Method

  • Cho, Byung-Geuk;Ha, Jung-Ik;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.232-242
    • /
    • 2013
  • To obtain phase currents information in AC drives, shunt sensing technology is known to show great performance in cost-effectiveness and therefore it is widely used in low cost applications. However, shunt sensing methods are unable to acquire phase currents in certain operation conditions. This paper deals with the derivation of the boundary conditions for phase current reconstruction in three-shunt sensing inverters and proposes a voltage injection method to expand the measurable areas. As the boundary conditions are deeply dependent on the switching patterns, they are typically analyzed on the voltage vector plane for space vector pulse width modulation (SVPWM) and discontinuous pulse width modulation (DPWM). In the proposed method, the voltage injection and its compensation are conducted within one sampling period. This guarantees fast current reconstruction and the injected voltage is decided so as to minimize the current ripple. In addition to the voltage injection method, a sampling point shifting method is also introduced to improve the boundary conditions. Simulation and experimental results are presented to verify the boundary condition derivation and the effectiveness of the proposed voltage injection method.

A New Random PWM Technique for Conducted-EMI Mitigation on Cuk Converter

  • Krishnakumar, C.;Muhilan, P.;Sathiskumar, M.;Sakthivel, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.916-924
    • /
    • 2015
  • Electromagnetic Interference (EMI) is a system to system or environment to system phenomenon. The literature survey proved that the Randomized Pulse Width Modulation (RPWM) technique is a promising technique to reduce EMI. A new Constant Trailing Edge, Randomized Pulse Width Modulation (CTERPWM) technique is proposed in this paper. The effect of the proposed RPWM technique for mitigation of conducted-EMI on Cuk converter operating in Continuous Conduction Mode (CCM) is simulated and tested. In this paper, the analytical expressions for the Power Spectral Density (PSD) are derived for the proposed RPWM technique and are validated by experimental measurements. The effectiveness of the proposed RPWM technique on the mitigation of conducted-EMI is verified comparing simulation and experimental results and it is identified that both the results are almost similar with allowable experimental deviations. The comparative investigation proves that the proposed RPWM technique can mitigate and spread the dominant peaks of conducted-EMI over the complete spectrum for the Cuk converter. Based on the investigation the CTERPWM technique is recommended for adoption.

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

THD Analysis of Output Voltage According to PWM Carriers in Single-Delta Bridge Cell MMC (Single-Delta Bridge Cell MMC의 전압합성을 위한 PWM 반송파 형태에 따른 출력전압의 THD 분석)

  • Jae-Myeong, Kim;Jae-Jung, Jung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.6
    • /
    • pp.526-534
    • /
    • 2022
  • The modular multilevel converter (MMC) has been widely applied to various industrial areas because of its various advantages and structural characteristics. Therefore, many methods for synthesizing the output voltage of MMC have been studied. Among these methods, phase-shifted pulse width modulation (PSPWM) is frequently used in MMC systems because it has diverse merits, such as excellent output qualities even with a small number of cells and uniform power distribution among cells. In this study, the total harmonic distortion (THD) of the output voltage is analyzed in accordance with the number of cells in one arm of a single-delta bridge cell MMC in order to compare PSPWM methods in terms of the THD of the output voltage. The physical characteristics of the triangle and sawtooth carrier waves used for the PSPWM and the mathematical modeling of output voltage are introduced. Then, the obtained results are verified through real-time simulation of a 1 MW single-delta bridge cell MMC system.