• 제목/요약/키워드: Pulse wave analysis

검색결과 243건 처리시간 0.032초

쌍트란지스터 회로에 의한 전류제어형 펄스변조 (Current Control Type Pulse Width Modulation by Using Pair Transistor Circuit)

  • 오현위
    • 대한전자공학회논문지
    • /
    • 제8권4호
    • /
    • pp.7-16
    • /
    • 1971
  • 쌍트란지스터 회로에 의하면 전류제어형의 부성저항소자가 가능하다. 이와같은 부성소자를 사용한 구형파발진회로의 바이어스전류에 신호파를 중첩함으로써 펄스폭변조회로를 구성하였다. 신호파가 정인 경우에는 한쪽의 트란지스터의 바이어스전류만을 증가시키고, 또 신호파가 부인 경우에는 다른 한쪽의 바이러스만을 증가시키는 방법을 채택하였다. 따라서 신호회로로서 일종의 전파정류회로의 변형을 채용하였다. 발진주기의 이론적해석과 회로정수결정의 설계지침을 구명하고 실험회로를 제시하였다.

  • PDF

Effects of Carrier Wave on the Brain Stem Electric Response (BER) in Scala Tympanic Electrode Array

  • Duck-Hwann Lim;Byu
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권2호
    • /
    • pp.105-112
    • /
    • 1982
  • Using electronic cochlear implant system, we studied in cats the difference in the response of the brain stem evoked response (BER) during the stimulation with the acoustic signals and the electric signals. These brain stem electric responses were analyzed using the integral pulse frequency modulation method of the auditory nervous system. Animal experimental results and the analysis show that the carrier wave hasimprored the frequency specificity. of the electronic auditory prosthesis.

  • PDF

콘볼루션 신경회로망을 이용한 능동펄스 식별 알고리즘 (Active pulse classification algorithm using convolutional neural networks)

  • 김근환;최승률;윤경식;이균경;이동화
    • 한국음향학회지
    • /
    • 제38권1호
    • /
    • pp.106-113
    • /
    • 2019
  • 본 논문은 능동소나 시스템이 비협동으로 운용될 경우 수신된 직접파로 부터 이를 탐지하여 식별하는 일련의 알고리즘을 제안하였다. 제안하는 알고리즘은 최근 다양한 분야에서 우수한 성능을 보여주고 있는 콘볼루션 신경회로망을 사용하였으며, 입력 데이터로 수신신호를 단시간 퓨리에 변환을 수행한 시간 주파수 분석 데이터를 사용하였다. 본 논문에서 사용한 콘볼루션 신경회로망의 구조는 두 개의 콘볼루션 계층과 풀링 계층을 사용하였으며, 출력층에 따라 데이터베이스 기반의 신경회로망과 펄스 특징인자 기반의 신경회로망을 설계하였다. 알고리즘의 성능을 검증하기 위해 실제 해상에서 수신한 3110개의 CW(Continuous Wave)펄스와 LFM(Linear Frequency Modulated) 펄스의 데이터를 가공하여 학습 데이터와 테스트 데이터를 구성하였다. 시뮬레이션을 수행한 결과 데이터베이스 기반의 신경회로망은 99.9 %의 정확도를 보였으며, 특징인자 기반의 신경회로망은 두 픽셀의 오차를 허용할 경우 약 96 %의 정확도를 보였다.

배플 플레이트를 가지는 고속철도 터널 출구로부터 방사하는 미기압파에 관한 연구 (Study on Impulse Wave Radiated from High Speed Railway Tunnel Exit with Baffle Plate)

  • 김태호;김동현;김희동
    • 한국가시화정보학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2018
  • Recently, as the high speed railway becomes more common, new environmental problems such as noise around tunnels are appearing. When a high speed train enters a tunnel, a compression wave in the tunnel is generated and propagated toward the tunnel exit at a sonic speed. When it reaches the tunnel exit, a part of compression wave radiates as a pulse typed impulse wave to the outside of tunnel. The impulse wave has an explosive noise. When the impulse wave is propagated around a village, it induces a serious noise or other problems to the resident. In order to solve these engineering problems, it is important to investigate the radiation characteristics of the impulse wave radiated from the tunnel exit. In this study, the effect of the length and angle of the baffle plate at the tunnel exit on the impulse wave radiated from the tunnel exit was investigated by numerical analysis. As a results, the baffle plate greatly affected the propagation of impulse wave.

맥파를 이용한 사상체질의 진단에 있어서 분류방법에 따른 진단의 정확도 비교 (Comparisons of the Accuracy of Classification Methods in Sasang Constitution Diagnosis with Pulse Waves)

  • 신상훈;김종열
    • 한국콘텐츠학회논문지
    • /
    • 제9권10호
    • /
    • pp.249-257
    • /
    • 2009
  • 사상의학은 체질에 따라 치료하는 방법을 달리하므로, 체질진단의 객관화가 절실히 요구되고 있다. 본 연구는 맥파를 이용하여 사상체질을 객관적으로 진단함에 있어서, 정확도가 높으면서 실용적인 체질분류 방법을 탐색하는 것이 목적이다. 한방병원에 건강검진을 목적으로 내원한 2848명의 피험자를 대상으로 전문의가 진단한 체질, 체질량지수, 혈압, 맥파 자료를 입수하였다. 자료의 선별과정을 통하여 최종적으로 1635명의 자료를 분석에 사용하였다. 판별분석, 회귀분석, 의사결정나무, 신경망으로 체질을 예측하고 전문의가 진단한 결과와 비교하여 분류방법의 정확도를 비교하였다. 판별분석은 체질별로 공분산 행렬이 동일해야 한다는 가정을 만족시키기 어려웠으며, 체질량지수를 고려하지 않은 의사결정나무와 신경망 분석의 결과는 분석표본의 변동에 민감했다. 체질분류에 결정적인 영향을 미치는 변수인 체질량지수가 고려된 로지스틱 회귀분석 또는 의사결정나무 방법이 체질분류 방법으로 추천할 만하다.

Ultrasonic characterization of exhumed cast iron water pipes

  • Groves, Paul;Cascante, Giovanni;Knight, Mark
    • Smart Structures and Systems
    • /
    • 제7권4호
    • /
    • pp.241-262
    • /
    • 2011
  • Cast iron pipe has been used as a water distribution technology in North America since the early nineteenth century. The first cast iron pipes were made of grey cast iron which was succeeded by ductile iron as a pipe material in the 1940s. These different iron alloys have significantly different microstructures which give rise to distinct mechanical properties. Insight into the non-destructive structural condition assessment of aging pipes can be advantageous in developing mitigation strategies for pipe failures. This paper examines the relationship between the small-strain and large-strain properties of exhumed cast iron water pipes. Nondestructive and destructive testing programs were performed on eight pipes varying in age from 40 to 130 years. The experimental program included microstructure evaluation and ultrasonic, tensile, and flexural testing. New applications of frequency domain analysis techniques including Fourier and wavelet transforms of ultrasonic pulse velocity measurements are presented. A low correlation between wave propagation and large-strain measurements was observed. However, the wave velocities were consistently different between ductile and grey cast iron pipes (14% to 18% difference); the ductile iron pipes showed the smaller variation in wave velocities. Thus, the variation of elastic properties for ductile iron was not enough to define a linear correlation because all the measurements were practically concentrated in single cluster of points. The cross-sectional areas of the specimens tested varied as a result of minor manufacturing defects and levels of corrosion. These variations affect the large strain testing results; but, surface defects have limited effect on wave velocities and may also contribute to the low correlations observed. Lamb waves are typically not considered in the evaluation of ultrasonic pulse velocity. However, Lamb waves were found to contribute significantly to the frequency content of the ultrasonic signals possibly resulting in the poor correlations observed. Therefore, correlations between wave velocities and large strain properties obtained using specimens manufactured in the laboratory must be used with caution in the condition assessment of aged water pipes especially for grey cast iron pipes.

보조전원장치에 의한 12-펄스정류기의 고조파 저감 (A harmonic reduction scheme for 12-pulse diode rectifiers by auxiliary voltage supply)

  • 김성환;김종수;오세진;윤경국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.916-922
    • /
    • 2014
  • 본 논문에서는 12-펄스정류기의 고조파 저감을 위해 12-펄스정류기의 커패시터 중앙 DC버스에 보조전원장치의 설치를 제안하였다. 그리고 이 장치에 의해 고조파가 감소되는 이론적인 배경을 다루었으며 부하전류의 크기에 따라 보조전원장치가 어떻게 제어되어야 하는지를 밝혔다. 본 논문에서 제안한 보조전원장치는 구형파 전압원을 적용함으로써 능동필터와 같은 다른 방식에 비해 시스템 구조가 간단하고 보다 저렴하다. 본 논문에서 제안하는 12-펄스정류기 고조파 저감법의 검증을 위해 소프트웨어 PSIM을 활용하였으며 제안된 방식의 유효성을 확인하였다.

지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구 (A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit)

  • 남동현;박영배;박영재;신상훈
    • 대한한의진단학회지
    • /
    • 제11권1호
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

복제 방지용 PUF 모델링을 위한 전자계 해석 (Electromagnetic Analysis to Design Unclonable PUF Modeling)

  • 김태용;이훈재
    • 한국정보통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1141-1147
    • /
    • 2012
  • 본 논문에서는 Debye 분산 특성을 가지는 복제 방지용 PUF를 설계하기 위한 전자계 해석 방안을 고려하였다. 공기층과 유전체 기판 위에 형성된 분산매질(Si)로 구성된 1차원 모델 내에 전파하는 펄스를 모형하기 위해 FDTD법을 이용하였다. 불연속 경계면에 도달한 펄스는 일부 반사되고 일부는 투과되어 빠르게 감쇠되는 것으로 나타났다. 그 결과 FDTD법에 의한 유전체 기판을 고려한 Debye 분산특성을 가지는 1차원 복제방지용 PUF 모델링에 적용 가능한 것을 확인하였다.