• 제목/요약/키워드: Pulse wave analysis

검색결과 243건 처리시간 0.027초

손목의 피부특성을 고려한 맥상파 해석모델 개발 (Development of Pulse Wave Analysis Model with Skin Effect)

  • 신상훈
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.159-168
    • /
    • 2011
  • Objectives: The purpose of this study is to develop the pulse wave analysis model with the palpation pressure and the skin effect. Methods: The position of pulse diagnosis was modeled with elastic string system. The skin was modeled with the elastic string, the palpation pressure with tension in the string, and the blood vessel pressure with external force on the string. Using the wave equation in the physics, the simplified pulse model was transformed to the mathematical model. Results: To the verification of the model, the effects of the palpation pressure and the skin effect were tested. Conclusions: There was optimal palpation pressure, describing the exact vessel pressure pattern and maximizing the amplitude of the skin displacement. For the optimal condition, the increased palpation pressure was needed with the increased skin thickness. Therefore, the developed pulse wave analysis model showed the good results.

대사증후군을 동반한 허혈성 뇌혈관 질환 환자의 맥파속도에 관한 연구 (Determinants of the Brachial-ankle Pulse Wave Velocity in Patients with Metabolic Syndrome and Ischemic Stroke)

  • 김동웅;박보라
    • 동의생리병리학회지
    • /
    • 제25권3호
    • /
    • pp.551-557
    • /
    • 2011
  • The purpose of this study is to investigate the relation between brachial-ankle pulse wave velocity and the features of metabolic syndrome, and differences according to sex in patients diagnosed cerebral infarction. The study group comprised 61 patients over age 30 who were diagnosed cerebral infarction, accompanied with metabolic syndrome. The brachial-ankle pulse wave velocity, blood pressure, lipid profiles, fasting blood glucose, body mass index were measured. Also we checked past history of patients. Then we analyzed the association between brachial-ankle pulse wave velocity and the features of metabolic syndrome. Pearson correlation analysis reflected the variables affecting the brachial-ankle pulse wave velocity as follows : Age, SBP(systolic blood pressure), DBP(diastolic blood pressure), FBS(fasting blood glucose) were positively correlated. As a result of regression analysis, in patients with cerebral infarction accompanied with metabolic syndrome, the brachial-ankle pulse wave velocity is affected by age to men, SBP, FBS, DBP to women. The brachial-ankle pulse wave velocity is not affected by the components of metabolic syndrome, except blood pressure, FBS, in patients with ischemic stroke.

토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화 (AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry)

  • 조정희;전영주;전민호;김영민
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

수중폭발 충격파와 가스구체 압력파를 함께 고려한 구조물의 동적응답해석 (Integrated Structural Dynamic Response Analysis considering the UNDEX Shock Wave and Gas Bubble Pulse)

  • 이상갑;권정일;정정훈
    • 대한조선학회논문집
    • /
    • 제44권2호
    • /
    • pp.148-153
    • /
    • 2007
  • Two typical impact loadings, shock wave and gas bubble pulse, due to UNDEX(UNDerwater EXplosion), should be considered together for the closest response analysis of structure subjected to UNDEX to a reality. Since these two impact loadings have different response time bands, however, their response characteristics of structure are different from each other. It is impossible to consider these effectively under the current computational environment and the mathematical model has not yet been developed. Whereas Hicks model approximates the fluid-structure interaction due to gas bubble pulse as virtual mass effect, treating the flow by the response of gas bubble after shock wave as incompressible ideal fluid contrary to the compressible flow due to shock wave, Geers-Hunter model could make the closest response analysis of structure under UNDEX to a real one as a mathematical model considering the fluid-structure interaction due to shock wave and gas bubble pulse together using acoustic wave theory and DAA(Doubly Asymptotic Approximation). In this study, the application and effectiveness of integrated dynamic response analysis of submerged structure was examined with the analysis of the shock wave and gas bubble pulse together.

촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토 (The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG.)

  • 류희영;허은정;김지현;윤정미;전성하
    • 동의신경정신과학회지
    • /
    • 제19권2호
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

미출산 여성과 출산 여성의 맥파 비교 - 난임 맥파 지표 연구를 위한 - (A Study on the Pulse Wave Parameter in Non Delivery and Delivery Women)

  • 서창운;김경철;김이순
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.200-215
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the differences of pulse wave parameter between the non delivery group (single women with no childbirth experience) and the delivery group (married women who gave birth(s) in delivery). Methods : Sixty one healthy (non delivery) nulliparous women and fifty three delivery women participated in this study. We used 3 dimensional pulse analyser(3D MAC, DAEYOMEDI co., Korea), which measures radial pulse waveform non-invasively by way of tonometry method at 5 different applied pressure levels. From 114 subjects enrolled, pulse wave parameters were measured on the six locations of Chon, Kwan and Cheok of each hands. Results : Delivery group's pulse showed larger values in the following pulse wave parameters (Energy, Ap, RAI, As, Aw, h1, h2, h4, h4/h1, t, t1, t2, t4, Wm, Wm/t). Non delivery group's pulse indicated larger values in the pulse wave parameters such as Energy of left Chon, difference pulse energy between left and right hand, Ad, h5, h5/h1, t5. Conclusions : According to the analysis result, delivery group's pulse has bigger values in most part of pulse wave parameters, especially in Kwan and Cheok which correspond to Liver, Kidney, and Myeong-mun. We interpret these results that delivery women are more mature and stable in reproductive organs than non delivery group, as they have experienced delivery(deliveries) and child-caring through married life.

Wave shape analysis of seismic records at borehole of TTRH02 and IWTH25 (KiK-net)

  • Kamagata, Shuichi
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.297-312
    • /
    • 2020
  • The KiK-net by NIED is a vertical array measurement system. In the database of KiK-net, singular pulse waves were observed in the seismic record at the borehole of TTRH02 during the mainshock (the magnitude of Japan Meteorological Agency (MJ) 7.3, MW 6.8) and aftershock (Mj 4.2) of Tottori-ken Seibu earthquake in 2000. Singular pulse waves were also detected in the seismic records at the borehole of IWTH25 during the Iwate-Miyagi Nairiku earthquake in 2008 (MJ 7.2, MW 6.9). These pulse waves are investigated by using the wave shape analysis methods, e.g., the non-stationary Fourier spectra and the double integrated displacement profiles. Two types of vibration modes are discriminated as the occurrence mechanism of the singular pulse waves. One corresponds to the reversal points in the displacement profile with the amplitude from 10-4 m to 10-1 m, which is mainly related to the fault activity and the amplification pass including the mechanical amplification (collision) of the seismograph in the casing pipe. The other is the cyclic pulse waves in the interval of reversal points, which is estimated as the backlash of the seismograph itself with the amplitude from 10-5 m to 10-4 m.

Pulse Shaper를 이용한 SHPB 실험 응력파 제어 효과의 해석 및 실험적 검증 (Numerical and Experimental Verification of Stress Wave Control Effect in SHPB Experiment using Pulse Shaper)

  • 김용희;우민아;강범수;김정
    • 소성∙가공
    • /
    • 제26권5호
    • /
    • pp.314-322
    • /
    • 2017
  • In the high-speed forming analysis, dynamic material properties considering a high strain rate are required. The split Hopkinson pressure bar (SHPB) experiment was performed for measuring dynamic material properties under high strain rate. The pulse shaping method was used to improve the accuracy of the SHPB experiment. A pulse shaper attached to the front of the incident bar was used for specimen dynamic stress equilibrium through stress wave control. Numerical analysis and SHPB test were performed to verify whether the pulse shaper affects the dynamic stress equilibrium in copper and Al6061 specimens. The results of SHPB test and numerical analysis show that the pulse shaper contributes to the dynamic stress equilibrium. Based on the improved stress equilibrium using a pulse shaper, the flow stress curves for copper and Al6061 materials were obtained at strain rates of 1344.4/sec and 1291.6/sec, respectively.

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥파의 주파수 분석 (A Study on the Effect of Food Intake on Radial Pulse using Fourier Analysis)

  • 임윤경;박광석
    • 대한한의학회지
    • /
    • 제32권4호
    • /
    • pp.139-148
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the effect of food intake on the Fourier components of radial pulse wave. Methods: Thirty-one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Fourier transform was performed and the frequency and amplitude of Fourier components were analyzed. Results: 1. The frequency and the amplitude of Fourier components of radial pulse wave increased significantly after food intake. 2. The frequency of Fourier components increased right after food intake and then gradually decreased as time passed, however the amplitude of Fourier components increased and maintained certain levels and patterns throughout the experimental period of 120 minutes. 3. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations. Conclusions: Food intake exerts an influence on radial pulse wave, resulting in increase of frequency and amplitude of Fourier components. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations.

영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석 (Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device)

  • 김동영;이상석;현석산;이진규
    • 한국자기학회지
    • /
    • 제24권5호
    • /
    • pp.146-151
    • /
    • 2014
  • 영구자석과 홀소자로 구비된 집게형 맥진기를 이용하여 목 부위의 경추동맥의 맥진파형과 손목 부위의 요골동맥 맥진파형을 각각 측정하였다. 두 개의 맥진파형을 비교하여 얻은 맥파전달시간과 맥파전달속도를 분석하였다. 맥파전달속도는 기존의 방식으로 측정한 값과 유사한 약 8.5 m/s으로 나타났다. 재현성과 신뢰성이 있는 한방의료기기인 집게형 맥진기로 얻은 맥파전달속도를 기준하여 동맥경화도를 예측할 수 있음을 제시하였다.