• Title/Summary/Keyword: Pulse types

Search Result 337, Processing Time 0.024 seconds

Study on the Characteristics of Heart Rate Variability, Body component analysis and accompanying symptoms in 175 Insomnia Patients (불면환자 175명의 심박변이도, 체성분 분석 및 동반증상의 특징에 관한 연구)

  • Ha, Ji-Won;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.4
    • /
    • pp.21-39
    • /
    • 2010
  • Objectives : This study was to investigate the characteristics of the heart rate variability(HRV), types of insomnia and accompanying symptoms of 175 insomnia patients. Methods : For this study we carried out HRV, Inbody of 175 patients with insomnia who have come to Dongeui oriental hospital of Dongeui university from the period of Janaury 2008 to September 2010. We studied the association of the insomnia patients' age and gender with HRV, accompanying symptoms and the types of insomnia. The information of the accompanying symptoms and types of insomnia was based on each patients' progress note. Results : l. There was no significant differences in the characteristics of HRV between male and female. 2. The most frequent symptom shown among the insmonia patents' was headache(41.14%). 3. Comparing the symptoms between the gender, female patients had more dry mouth, alternative periodic chill and fever, and hot flush symptoms than the male patients. 4. Comparing the symptoms between the age groups(divided in two), the lower age group (20~59) had more dizziness and constipation symptoms than the higher age group (over 60). 5. Comparing the types of insomma between the age group, the higher age group (over 60) had more termination insomnia. 6. The types of insomnia of the entire insomnia patients were onset insomnia (73.1%), maintenance insomnia(20.6%), termination insomma(l7.1 %), shallow sleep (52.6%), listed by order of frequency. 7. The patients who takes hypnotics had more anorexia symptoms than the patients who doesn't take hypnotics. 8. There was no visible differences of the average fractal portrait between male and female. The age group of 20~30yrs. had the highest average fractal portrait, and the age group of 30~59yrs. the second highest, and the age group over 60yrs. the lowest. 9. The average of the regulation reserves of the autonomic nervous system(B2) - was lower than the regulation level of the ANS at the present (Bl). 10. When compared the priority of the function of the ANS, it showed that the proportion of HF($38.61{\pm}29.19%$)was the most, and than VLF($30.65{\pm}23.36%$), LF($20.04{\pm}19.13%$) the least. 11. The average of the compensation level of the central nervous system at present(Cl) - was lower than the compensation reserves of the CNS(C2). 12. The average of the control reserves of the cerebrum(D2) - was lower than the control level of the cerebrum at the present (Dl). 13. There was no visible differences between different sexes and ages in pulse rate. 14. The abdomen fat ratio above the line of the insomnia patients was 77.97% in male and 93.1% in female. Both sexes showed that insomnia patients had more abdomen fat that the standard, and female patients had more abd. fat than male patients. Conclusions : This study shows that the HRV of insomnia patients had no significant differences between gender. Fractal portrait, HF, LF and VLF of the insomnia patients are in inverse proportion to the age. The study of the Body Component Analysis showed that female had more abdomen fat than male, and both gender showed more abdomen fat than the standard. When looked into the accompanying symptoms of the insomnia patients, the symptoms show differences according to gender, age and hypnotics taking, as shown as below. In the entire patients, Headache was the most accompanying symptom. Female had more dry mouth, alternative periodic chill and fever, and hot flush symptoms than male. Higher age groups had more dizziness and constipation as accompanying symptoms than lower age groups. Patients who takes hypnotics had more anorexia than those who dont.

Optimization of Procedure for Efficient Gene Transfer into Porcine Somatic Cells with Lipofection

  • Kim, D.Y.;McElroy, S.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.5
    • /
    • pp.648-656
    • /
    • 2008
  • The objective of this study was to establish conditions for transfection of a foreign gene into somatic cells using cationic lipid reagents and to evaluate the effects of transfection on in vitro development of somatic cell nuclear transfer (SCNT) embryos. Green fluorescent protein (GFP) gene was used as a foreign gene and a non-transfected somatic cell was utilized as a control karyoplast. Monolayers of porcine cells were established and subsequently transfected with a GFP-expressing gene (pEGFP-N1) using three types of transfection reagents (LipofectAMINE PLUS, FuGENE 6 or ExGen500). Donor cells used for SCNT included transfected fetal or adult fibroblasts and oviduct epithelial cells, either serum-fed or serum-starved. Oocytes matured in vitro for 42 h were reconstructed with either transfected or non-transfected porcine somatic cells by electric fusion and activation using a single DC pulse of 1.8 kV/cm for $30{\mu}s$ in $Ca^{2+}$ and $Mg^{2+}-containing$ 0.26 M mannitol solution. Reconstructed oocytes were subsequently cultured in NCSU-23 medium for 168 h and the developmental competence and cell number in blastocyst were compared. There were no significant differences (P>0.05) in fusion, cleavage rates or development to the blastocyst stage between non-transfected, transfected, serum-fed and serum-starved cells. However, the rates of GFP-expressing blastocysts were higher in the FuGENE 6 group (71.4%) among transfection reagents and in the fetal fibroblasts group (70.4%) for donor cells. These results indicate that fetal fibroblasts transfected with FuGENE 6 can be used as donor cells for porcine SCNT and that GFP gene can be safely used as a marker of foreign genes in porcine transgenesis.

Influence of Stress Experience on Change of Attention (스트레스 사건의 경험이 주의변화에 미치는 영향)

  • 최남희;이남희;김희숙
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.2
    • /
    • pp.214-226
    • /
    • 1990
  • For a man to maintain attention, he needs to keep a certain level of arousal. An inordinate increase or decrease in the level of arousal eventually has a negative influence on attention. Precedent research has shown that the degree of attention changes when an experience of stress is related to anxiety resulting in a rise in arousal. This research was done to examine this hypothesis by looking at the 27 female students, 14 of whom had failed in the annual examination. The results of the investigation are as follows : The stress of failure in the examination was seen to raise the level of physiological arousal. Although pulse and electromyography showed no significant change, further inquiries should be made based on other types of methodology. In spite of the rise of arousal, the performance of selective task was degraded. This suggests those students failed to give moderate attention to given information for that kind of task. But the exact reason of that failure was not identified : that is it was difficult decide whether they gave too much attention to the anxiety brought about by stress. Performance of integral tasks, however, did not show any degradation. Judging from these results, stress seems to exert significant influence on attention in the selection of the appropriate information among the various options given. This offers an important hint in relation to the health care situation where nursing information is offered. Clients who receive nursing information in stressful situations may have difficulty in separating and selecting this helpful information from other options which they have acquired through their life experience. The content and terminology of nursing information may be strange and unintelligible to clients, although they are quite familiar and distinct to nurses. So, it is desirable for nurses to give, in addition and at the same time when nursing information is given, some certain related information as devices for selection, instead of merely giving nursing informations as such. So far it is not clear whether the concepts of information processing theory can be suitably applied to nursing. However, it is obvious, according to this research, that the quality of attention is disturbed in the stress situation. This is why further inquiries should be made into attention in practical nursing situation.

  • PDF

Transcutaneous electrical nerve stimulation, acupuncture, and spinal cord stimulation on neuropathic, inflammatory and, non-inflammatory pain in rat models

  • Sato, Karina Laurenti;Sanada, Luciana Sayuri;da Silva, Morgana Duarte;Okubo, Rodrigo;Sluka, Kathleen A.
    • The Korean Journal of Pain
    • /
    • v.33 no.2
    • /
    • pp.121-130
    • /
    • 2020
  • Background: Transcutaneous electrical nerve stimulation (TENS), manual acupuncture (MA), and spinal cord stimulation (SCS) are used to treat a variety of pain conditions. These non-pharmacological treatments are often thought to work through similar mechanisms, and thus should have similar effects for different types of pain. However, it is unclear if each of these treatments work equally well on each type of pain condition. The purpose of this study was to compared the effects of TENS, MA, and SCS on neuropathic, inflammatory, and non-inflammatory pain models. Methods: TENS 60 Hz, 200 ㎲, 90% motor threshold (MT), SCS was applied at 60 Hz, an intensity of 90% MT, and a 0.25 ms pulse width. MA was performed by inserting a stainless-steel needle to a depth of about 4-5 mm at the Sanyinjiao (SP6) and Zusanli (ST36) acupoints on a spared nerve injury (SNI), knee joint inflammation (3% carrageenan), and non-inflammatory muscle pain (intramuscular pH 4.0 injections) in rats. Mechanical withdrawal thresholds of the paw, muscle, and/or joint were assessed before and after induction of the pain model, and daily before and after treatment. Results: The reduced withdrawal thresholds were significantly reversed by application of either TENS or SCS (P < 0.05). MA, on the other hand, increased the withdrawal threshold in animals with SNI and joint inflammation, but not chronic muscle pain. Conclusions: TENS and SCS produce similar effects in neuropathic, inflammatory and non-inflammatory muscle pain models while MA is only effective in inflammatory and neuropathic pain models.

Modeling of Wavelength Conversion Charateristics in Directionally Coupled Semiconductor Optical Amplifier (반도체 광증폭기로 형성된 방향성 결합기에서의 파장변환 특성 모델링)

  • Chung, Ho-Young;Chung, Young-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.43-53
    • /
    • 2001
  • Wavelength conversion devices are essential to build an expanding all-optical network, and various types of wavelength conversion techniques are being researched. Among them, wavelength conversion based on the cross phase modulation in a directionally coupled semiconductor optical amplifier has been introduced and the concept has been experimentally proved. In this paper, a split-step method is applied to properly model the mentioned wavelength converter in the time-domain and various characteristics have been analyzed. It is shown that the present modeling approach can explain the results of the reported experimental results. Furthermore the wavelength conversion is shown to be well performed when the input signal wave and the converted wave travels in the opposite direction. The simulation shows that the positive and negative chirping appear simultaneously at both the leading and trailing of edges of the optical pulse.

  • PDF

The Effect of Napping of Knitted Fabric on Wear Sensation (편성물의 기모가공이 착용감에 미치는 영향)

  • Lee Jong-Min;Lee Soon-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.11 no.3 s.25
    • /
    • pp.41-55
    • /
    • 1987
  • The purpose of this study is to investigate the effects of napping of knitted fabric on wear sensation and physiological responses. Experimental garments were four types of warm-ups made of either $100\%$ PET or $65/35\%$ P /C and either napped or unnapped respectively. Two healthy young female adults were chosen as subjects for the experiment. Experimental room conditions were as follows: Temp., $22\pm0.5^{\circ}C$ R.H., $54\pm3\%$ and Air Velocity, 0.25m/ sec or 2. 86m/sec. The subjects exercised on bicycle ergometer and rested alternatively for totally 45-min. The results are summarized as follows. 1) With napped Warm-up, chest, back, mean skin temp. and microclimates, i.e., temp., relative humidity and water vapor pressure inside the clothing, were higher than with unnapped warm-up. And there was no difference in pulse rate between napped and unnapped warm-ups. 2) Wear sensations of thermal, humidity, tactile and comfort were 'more hot' and 'more uncomfortable' in 0.25m/sec air velocity. but in 2.86m/sec condition the tactile sensation was 'better' and 'more comfortable' with napped warm-ups. According to Pearson's Correlation, among various kinds of wear sensations, tactile is most related with comfort. From these results, it can be concluded that napped fabric decreases the rate of heat trans? mission and moisture diffusion through the clothing. Therefore skin and body temp. and temp., R.H., Vapor Pressure inside the clothing are increased.

  • PDF

Numerical Analysis for Contaminant Transport using a Dual Reactive Domain Model

  • 정대인;최종근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.122-126
    • /
    • 2002
  • Contaminant transport in porous media is characterized by solving an advection-dispersion equation(ADE). The ADE can cover equilibrium phenomena of interest, which include sorption, decay, and chemical reactions. Among these phenomena, sorption mechanism is described by several types of sorption isotherm. If we assume the sorption isotherm as linear, the solution of ADE can be easily procured. However, if we consider the sorption isotherm as non-linear isotherm like a Dual Reactive Domain Model (DRDM), the resulting differential equation becomes non-linear. In this case, the solution of ADE cannot be easily acquired by an analytic method. In this paper, we present the numerical analysis of ADE using a DRDM. The results reveal that even if sorption data may be fitted well using linear or non-linear isotherm, the characteristics of contaminant transport of the two cases are different from each other. To be concrete, the retardation of linear isotherm has stronger effect than that of the DRDM. As the non-linearity of sorption isotherm increases, the difference of retardation effects of the two cases becomes larger. For a pulse source, the maximum concentration of the linear model is higher than that of the DRDM, but the plume of the DRDM moves faster than that of the linear model. Behaviors of contaminant transport using the DRDM are consistent with common features of a linear model. For instance, biodegradation effect becomes larger as time goes by The faster the seepage velocity is, the faster the plume of contaminant moves. The plume of the contaminant is distributed evenly over overall domain in the event of high dispersion coefficient.

  • PDF

An Experimental Study on the Development of Lightweight Concrete (경량콘크리트의 개발에 관한 실험적 연구)

  • 김성완;성찬용;민정기;정현정
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.5
    • /
    • pp.90-100
    • /
    • 1995
  • This study was performed to develop the lightweight concrete using synthetic lightweight aggregate and natural coarse aggregate. Mixing ratios were three types, the first type was mixed cement and synthetic lightweight fine aggregate (Type CP), the second type was mixed cement, synthetic lightweight fine aggregate and synthetic lightweight coarse aggregate (Type CPE), the third type was mixed cement, synthetic lightweight fine aggregate and natural coarse aggregate (Type CPN). The results of this study are summarized as follows ; 1. The W/C of each mixing ratio was increased with increase of the amount of cement used, and it was shown higher in order of Type CP, CPN, CPE. 2. The unit weight of Type CP, CPE and CPN was 1.473~1.647g/cm$^3$, 1.467~1.622g/cm$^3$ and 1.658~1 .838g/cm$^3$, respectively. And the absorption ratio was approximately 20%, which was higher than that of the normal cement concrete. 3. The compressive strength of Type CP was shown 178 ~249kg/cm2, Type CPE was shown 149~241kg/cm$^2$ and Type CPN was shown 196~297kg/cm$^2$, respectively. Each strength ratio was smaller than that of the normal cement concrete. 4. The pulse velocity of Type CP, CPE and CPN was 2, 688~3, 240m/sec, 2, 981~3, 324m/sec and 2, 989 ~ 3, 545m/sec, respectively. And it was increased with increase of strength and unit weight. 5. The length change ratio at 28 days was in the range of 0.057~0.077%, and earlier length change ratio was higher than that of the later.

  • PDF

Rotor Failures Diagnosis of Squirrel Cage Induction Motors with Different Supplying Sources

  • Menacer, Arezki;Champenois, Gerard;Nait Said, Mohamed Said;Benakcha, Abdelhamid;Moreau, Sandrine;Hassaine, Said
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.219-228
    • /
    • 2009
  • The growing application and the numerous qualities of induction motors (1M) in industrial processes that require high security and reliability levels has led to the development of multiple methods for early fault detection. However, various faults can occur, such as stator short-circuits and rotor failures. Traditionally the diagnosis machine is done through a sinusoidal power supply, in the present paper we study experimentally the effects of the rotor failures, such as broken rotor bars in function of the ac supplying, the load and show the impact of the converter from diagnosis of the machine. The technique diagnosis used is based on the spectral analysis of stator currents or stator voltages respectively according to the types of induction motor ac supplying. So, four different ac supplying are considered: ${\odot}$ the IM is directly by the balanced three-phase network voltage source, ${\odot}$ the IM is fed by a sinusoidal current source given the controlled by hysteresis, ${\odot}$ the IM is fed (in open loop) by a scalar control imposing through ratio V/f=constant, ${\odot}$ the IM is controlled through a vector control using space vector pulse width modulation (SVPWM) technique inverter with an outer speed loop.

Optical Characteristics of Bolometric Terahertz Sensor (볼로미터형 테라헤르츠 센서의 광학적 특성 연구)

  • Han, Myung Soo;Song, Woosub;Hong, Jung Taek;Lee, Donghee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • The optical characteristics of a terahertz (THz) antenna-coupled bolometer (ACB) detector were evaluated using a pulsed quantum cascade laser (QCL) and radiation blackbody sources. We investigated a method for measuring the responsivity and noise-equivalent power (NEP) of the THz detector using two different types of light sources. When using a QCL source with a frequency of 3 THz, the average responsivity of 24 devices was $1.44{\times}10^3V/W$ and the average NEP of those devices was $3.33{\times}10^{-9}W/{\surd}Hz$. The average responsivity and NEP as measured by blackbody source were $1.79{\times}10^5V/W$ and $6.51{\times}10^{-11}W/{\surd}Hz$, respectively, with the measured values varying depending on the light source. This was because the output power of each light source was different, with the laser source being driven by a pulse type wave and the blackbody source being driven by a continuous wave. The power input to the THz sensor was also different. Futhermore, the responsivity and NEP values measured using band pass filter (BPF) were similar to those measured when using only THz windows. It was found that ACB sensor responds normally in the THz region to both the laser and the blackbody source, and the method was confirmed to effectively evaluate the characteristics of the THz sensor.