• Title/Summary/Keyword: Pulse types

Search Result 337, Processing Time 0.028 seconds

Comparison of Longitudinal Wave Velocity in Concrete by Ultrasonic Pulse Velocity Method and Impact-Echo Method (초음파 속도법과 충격반향기법에 의한 콘크리트의 종파 속도 비교)

  • Lee, Hoi-Keun;Lee, Kwang-Myong;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.2
    • /
    • pp.98-106
    • /
    • 2003
  • Nondestructive test (NDT) provides much information on concrete without damage of structural functions. Of NDT methods, elastic wave propagation methods, such as ultrasonic pulse velocity (UPV) method and impact-echo (IE) method, have been successfully used to estimate the strength, elastic modulus, and Poisson's ratio of concrete as well as to detect the internal microstructural change and defects. In this study, the concretes with water-binder ratio ranging from 0.27 to 0.50 and fly ash content of 20% were made and then their longitudinal wave velocities were measured by UPV and IE method, respectively. Test results showed that the UPV is greater than the longitudinal wave velocity measured by the If method, i.e., rod-wave velocity obtained from the same concrete cylinder. It was found that the difference between the two types of velocities decreased with increasing the ages of concrete and strength level. Moreover, for the empirical formula, the dynamic Poisson's ratio, static and dynamic moduli of elasticity, and velocity-strength relationship were determined. It was observed that the Poisson's ratio and the modulus of elasticity determined by the dynamic method are greater than those determined by the static test. Consequently, for the more accurate estimation of concrete properties using the elastic wave velocities, the characteristics of these velocities should be understood.

A Research on The Pulse & Disease-patterns and Diagnostic Theory of Exogenous Febrile Disease in the "Sanghanjeonsaengjip(傷寒全生集)" ("상한전생집(傷寒全生集).변상한발열례(辨傷寒發熱例)" 등에 대한 연구(硏究))

  • Choi, Dong-Su;Sheen, Yeong-Il1
    • Journal of Korean Medical classics
    • /
    • v.23 no.4
    • /
    • pp.103-153
    • /
    • 2010
  • "Sanghanjeonsaengjip(傷寒全生集)" is a classic medical work, written by the outstanding physician Dohwa(陶華) in the Ming Dynasty. The characteristic of "SangHanJeonSaengJip" is that this book succeeded to the spirit of pattern identification and treatment of Treatise on Cold Damage Diseases, newly changed a table of contents by symptoms, and together with this indicated the prescriptions in accordance with diswase-pattern at "YujeunghwalInseo(類證活人書)", "Hwajegookbang(和劑局方)" etc. Also because this kept the existing ephedra decoction, cinnamom twig decoction, minor decoction of bupleurum, decoction for reinforcing middle-energizer and replenishing qi etc.'s name on and unlikely indicated the medicine composition, it caused confusion, but at the later ages "Euhakipmun(醫學入門)" the so-called 'Doci(陶氏)' was added to the prescription name, so we are able to distinguish. Together with this, this book dose not indicate the dosage of medicine and indicates the first, the second, and the third classes[上中下] below medicine. As this dose not mean the three grades of quality"good, fair, and poor[上中下] of "Shennong's Classic of Materia Medica" but expresses the sovereign medicinal as the first class[上], minister medicinal as the second class[中] and assistant and courier medicinal as the third class[下], doctors can voluntarily decide the dosage of medicine in accordance with the degree of disease. At this thesis, I single out ten chapters in contents of 2nd volume named Hyeong(亨) corresponding to the details, among "Sanghanjeonsaengjip(傷寒全生集)". I discussed superficial fever types of exogenous febrile disease in chapter 1, aversion to cold types of exogenous febrile disease in chapter 2, syndrome caused un-sufficient sweating in chapter 3, organic fever types of exogenous febrile disease in chapter 4, aversion to wind types of exogenous febrile disease in chapter 5, Tidal fever types of exogenous febrile disease in chapter 6, Alternative attacts of chills and fever in chapter 7, Dysphoria with smothery sensation in chapter 8, Fidgetiness of exogenous febrile disease in chapter 9, and Headache of exogenous febrile disease in chapter 10, and together with this I discussed, in detail, which influence the prescriptions which are listed on each chapter have caused on future generations In accordance with this, I think that the above-mentioned symptoms and prescriptions are important when I research cold damage and warm disease study. So I orderly research revision, annotation, rendering and an investigation.

Experimental investigation of Scalability of DDR DRAM packages

  • Crisp, R.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.4
    • /
    • pp.73-76
    • /
    • 2010
  • A two-facet approach was used to investigate the parametric performance of functional high-speed DDR3 (Double Data Rate) DRAM (Dynamic Random Access Memory) die placed in different types of BGA (Ball Grid Array) packages: wire-bonded BGA (FBGA, Fine Ball Grid Array), flip-chip (FCBGA) and lead-bonded $microBGA^{(R)}$. In the first section, packaged live DDR3 die were tested using automatic test equipment using high-resolution shmoo plots. It was found that the best timing and voltage margin was obtained using the lead-bonded microBGA, followed by the wire-bonded FBGA with the FCBGA exhibiting the worst performance of the three types tested. In particular the flip-chip packaged devices exhibited reduced operating voltage margin. In the second part of this work a test system was designed and constructed to mimic the electrical environment of the data bus in a PC's CPU-Memory subsystem that used a single DIMM (Dual In Line Memory Module) socket in point-to-point and point-to-two-point configurations. The emulation system was used to examine signal integrity for system-level operation at speeds in excess of 6 Gb/pin/sec in order to assess the frequency extensibility of the signal-carrying path of the microBGA considered for future high-speed DRAM packaging. The analyzed signal path was driven from either end of the data bus by a GaAs laser driver capable of operation beyond 10 GHz. Eye diagrams were measured using a high speed sampling oscilloscope with a pulse generator providing a pseudo-random bit sequence stimulus for the laser drivers. The memory controller was emulated using a circuit implemented on a BGA interposer employing the laser driver while the active DRAM was modeled using the same type of laser driver mounted to the DIMM module. A custom silicon loading die was designed and fabricated and placed into the microBGA packages that were attached to an instrumented DIMM module. It was found that 6.6 Gb/sec/pin operation appears feasible in both point to point and point to two point configurations when the input capacitance is limited to 2pF.

Two Types of Voltage-activated Calcium Currents in Goldfish Horizontal Cells

  • Paik, Sun-Sook;Bai, Sun-Ho;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.5
    • /
    • pp.269-273
    • /
    • 2005
  • In horizontal cells (HCs) that were freshly dissociated from goldfish retina, two types of voltagedependent calcium currents ($I_{Ca}$) were recorded using a patch-clamping configuration: a transient type current and a sustained type current. The cell was held at -40 mV, and the prepulse step of -90 mV was applied before command pulse between -65 and +55 mV. The transient $Ca^{2+}$ current was activated by depolarization to around -50 mV from a prepulse voltage of -90 mV lasting at least 400 ms and reached a maximal value near -25 mV. On the other hand, the sustained $Ca^{2+}$ current was induced by pre-inactivation for less than 10 ms duration. Its activation started near -10 mV and peaked at +20 mV. $Co^{2+}$ (2 mM) suppressed both of these two components, but nifedipine ($20{\mu}M$), L-type $Ca^{2+}$ channel antagonist, blocked only the sustained current. Based on the activation voltage and the pharmacolog$I_{Ca}$l specificity, the sustained current appears to be similar to L-type $I_{Ca}$ and the transient type to T-type $I_{Ca}$. This study is the first to confirm that transient type $I_{Ca}$ together with the sustained one is present in HCs dissociated from goldfish retina.

Development of Animal Health Monitoring System Model V. Analysis of Risk Factors in Clinical Part (동물(젖소)건강 Monitoring system 모델 개발 V. 임상학적 위해요소 분석)

  • 최민철;김종수;김곤섭;김용환;이효종;손우진;원현희
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.439-442
    • /
    • 1999
  • An animal health monitoring system in Gyeongnam area (near-Chinju) was studied to evaluate the environmental risk factors, physical examinations and 4 disease entities(abomasal displacement, traumatic reticulopericarditis & -peritonitis, milk fever and lameness) in 40(34 in second year)dairy herds (total 1253 dairy cattle). In feeding environments, we examined housing system, forage percentage in ration, stall types, playground, cleanness of stall. In housing system, most of herds (60%) have tie-stall types and 36 herds are open-type housing. The forage ratio of ration was less than 50% in most of herds (67%). 39 herds had their own playgrounds and the frequency of playground cleanness was irregular, Physical examinations included the T(temperature), P (pulse), R (respiration), abnormalities of superficial lymph nodes, claw examination and total CBC with blood from tail veins. T, P, R are within normal limits (T : 38.1$\pm$0.6$^{\circ}C$, P : 84.6$\pm$12.9/min., R : 24.0$\pm$7.6/min. ,respectively), the swelling of lymph nodes were shown in 13 cattle and overall claw trimming was required in 3 herds. In blood examination, 23 cattle showed leuko-cytosis and 7 cattle showed low RBC and hemoglobin level, the other cattle were within normal limits (WBC : 8.90$\pm$2.06 10$^3$/ul., RBC : 6.36$\pm$1.02 10$^{6}$ ul, Hb : 9.83$\pm$ 1.20 g/dl PCV : 27.43$\pm$5.67 %, respectively). In 4 disease entities, we found some metallic foreign bodies in men of 13 cattle, which had predisposing factors of traumatic reticulopericarditis and reticuloperitonitis, 13 abomasal displacement, 51 milk fever and lameness in 39 cattle.

  • PDF

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

Effect of fiber type and content on properties of high-strength fiber reinforced self-consolidating concrete

  • Tuan, Bui Le Anh;Tesfamariam, Mewael Gebregirogis;Hwang, Chao-Lung;Chen, Chun-Tsun;Chen, Yuan-Yuan;Lin, Kae-Long
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.299-313
    • /
    • 2014
  • Effects of polypropylene (PP) fibers, steel fibers (SF) and hybrid on the properties of highstrength fiber reinforced self-consolidating concrete (HSFR-SCC) under different volume contents are investigated in this study. Comprehensive laboratory tests were conducted in order to evaluate both fresh and hardened properties of HSFR-SCC. Test results indicated that the fiber types and fiber contents greatly influenced concrete workability but it is possible to achieve self consolidating properties while adding the fiber types in concrete mixtures. Compressive strength, dynamic modulus of elasticity, and rigidity of concrete were affected by the addition as well as volume fraction of PP fibers. However, the properties of concrete were improved by the incorporation of SF. Splitting tensile and flexural strengths of concrete became increasingly less influenced by the inclusion of PP fibers and increasingly more influenced by the addition of SF. Besides, the inclusion of PP fibers resulted in the better efficiency in the improvement of toughness than SF. Furthermore, the inclusion of fibers did not have significant effect on the durability of the concrete. Results of electrical resistivity, chloride ion penetration and ultrasonic pulse velocity tests confirmed that HSFR-SCC had enough endurance against deterioration, lower chloride ion penetrability and minimum reinforcement corrosion rate.

A study of Agricultural fatigue shoes - A comparative study of heat load by shoe type - (농작업화에 관한 연구 - 신발종류에 따른 열적 부담 비교연구 -)

  • 이경숙;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.7 no.2
    • /
    • pp.99-108
    • /
    • 1996
  • This study has intended to suggest fundamental data to develope and choose appropriate shoes for upland farming in order to prevent health deterioration of women workers and improve work effectiveness and reduce fatigue by wearing appropriate shoes. During 1995. 4. 28 - 5. 10, Fifty women workers in hot pepper farming were observed and major shoe types, which were rubber shoes, walking shoes, slippers, and rubber boots, were selected for the study. During 1995. 10. 9 - 31, two subjects were tested by wearing those shoes in the laboratory where the temperature was 24$\pm$1$^{\circ}C$ and relative humidity 50$\pm$5%RH. And the temperature & humidity on sole and in the shoes, the rectal temperature, skin temperature, blood pressure, pulse, lactate concentration of blood, Flickers' value and subjective sensation were measured. The results were as follows : 1. 84% of women workers mentioned that they need shoes improvement and the order of most frequent shoe types to be worn was rubber shoes, walking shoes, slippers, rubber boots. 2. The rate of women who were unsatisfied with shoes for upland farming is 38 percentages. The reason of unsatisfaction was that feet were in a sweat and alien substances were let into shoes. 3. The temperature & humidity on sole were the lowest in rubber boots during experiment(p<0.01). 4. The relative humidity in the shoes was the highest in rubber boots by 90% and the lowest in walking shoes by 72% during rest And the humidity in slippers and walking shoes were significantly low in experiment(p<0.001). 5. Rubber boots showed the highest rise in rectal temperature by 0.2$^{\circ}C$ showing increase of core temperature (p<0.05). 6. The mean skin temperature during experiment was highest in rubber boots by 33.8$^{\circ}C$(p<0.001).

  • PDF

Development and Evaluation of Repeatability of the Integrated Constitutional Diagnosis System (통합 체질진단 시스템 개발 및 반복성 평가)

  • Jeon, Young-Ju;Kim, Jang-Woong;Kim, Jae-Uk;Bae, Jang-Han;Kim, Jong-Yeol;Kim, Keun-Ho
    • Journal of Sasang Constitutional Medicine
    • /
    • v.24 no.3
    • /
    • pp.34-41
    • /
    • 2012
  • Objectives In this study, we developed a mock-up of the system for Sasang Constitutional (SC) diagnosis. This system consists of 5 devices which are the face analyzer, the voice analyzer, the skin analyzer, the pulse analyzer, and the computer-based questionnaire. Our goal is to evaluate the repeatability of the system. Methods Each device is capable of classifying SC types. The classification probability of the integrated system for the SC types was obtained by summing the probability from each device. For evaluating the repeatability of the system, we collected data for 5 subjects, and repeated the measurement three times for each individual. The average and standard deviation were used for calculating the Coefficient of Variation. Results The results showed that the repeatability of the classification probability of the integrated system is about 8%, which implies the system is repeatable. Conclusions To increase usability of this system, it is desirable for the system to offer information on health condition of the user. The integrated constitutional diagnosis system will be upgraded to complement the convenience and to develop the diagnostic algorithm for the user's health condition.

Implementation of Simplified Electronic Measuring Devices Using Java Applets (자바 애플릿을 이용한 단순화된 전자계측장비의 구현)

  • Kim, Dongsik;Moon, Ilhyun;Woo, Sangyeon
    • The Journal of Korean Association of Computer Education
    • /
    • v.10 no.6
    • /
    • pp.69-77
    • /
    • 2007
  • In this paper we implement main functions of electronic measuring devices, which are essential to design electric/electronic virtual laboratories on the Web. The implemented virtual electronic measuring devices such as virtual analog multimeter(VAM), virtual function generator(VFG), virtual oscilloscope(VOSC) enable the learners to perform the virtual experiments on the Web by simple mouse clicks. In order to show their validity virtual experiments for understanding how to use them are designed. The virtual experiments for measuring resistance(OHM), AC/DC Voltage(ACV/DCV) and DC Current(DCA) by the VAM are illustrated. In addition, the learners can change the frequency of the signal generated from the VFG and measure by the VOSC several types of the signals generated from the VFG such as triangular, pulse, sinusoidal waveforms. The VOSC can measure voltage and current through two channels of it and provide the learners with additional functions such as zooming, trigger, cursor, summing of waveforms. Since the virtual electronic measuring devices have been implemented as forms of Java classes, various types of applications are available according to the structures of virtual laboratories.

  • PDF