• Title/Summary/Keyword: Pulse types

Search Result 337, Processing Time 0.023 seconds

Modeling and Analysis of Cushioning Performance for Multi-layered Corrugated Structures

  • Park, Jong Min;Kim, Ghi Seok;Kwon, Soon Hong;Chung, Sung Won;Kwon, Soon Goo;Choi, Won Sik;Kim, Jong Soon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.221-231
    • /
    • 2016
  • Purpose: The objective of this study was to develop cushion curves models and analyze the cushioning performance of multi-layered corrugated structures (MLCS) using a method based on dynamic stress-energy relationship. Methods: Cushion tests were performed for developing cushion curve models under 12 combinations of test conditions: three different combinations of drop height, material thickness, and static stress for each of four levels of energy densities between 15 and $60kJ/m^3$. Results: Dynamic stress and energy density for MLCS followed an exponential relationship. Cushion curve models were developed as a function of drop height, material thickness, and static stress for different paperboards and flute types. Generally, the differences between the shock pulse (transmitted peak acceleration) and cushion curve (position and width of belly portion) for the first drop and the averaged second to fifth drop were greater than those for polymer-based cushioning materials. Accordingly, the loss of cushioning performance of MLCS was estimated to be greater than that of polymer-based cushioning materials with the increasing number of drops. The position of the belly of the cushion curve of MLCS tends to shift upward to the left with increasing drop height, and the belly portion became narrower. However, depending on material thickness, under identical conditions, the cushion curve of MLCS showed an opposite tendency. Conclusions: The results of this study can be useful for environment-friendly and optimal packaging design as shock and vibrations are the key factors in cushioning packaging design.

Development of Fast Side-impact Sensing Algorithm (고속 측면 충돌 감지 알고리즘의 개발)

  • 박서욱;김현태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.3
    • /
    • pp.163-170
    • /
    • 2000
  • Accident statistics shows that the portion of fatal occupant injuries due to side impacts is considerably high. The side impact usually leads to a severe intrusion of side structure into the passenger compartment. Furthermore, the safety zone for the side impact is relatively small compared to the front impact. Those kinds of physics for side impact frequently result in a fatal injury for the occupant. Therefore, NHTSA and EEVC are trying to intensify the regulation for the occupant protection against side impact. Both the regulation and recent market trends are asking for an installation of side airbag. There are several types of system configuration for side impact sensing. In this paper, we adopt the acceleration-based remote sensing method for the side airbag control system. We mainly focus on the development of hardware and crash discrimination algorithm of remote sensing unit. The crash discrimination algorithm needs fast decision of airbag firing especially for high-speed side impact such as FMVSS 214 and EEVC tests. It is also required to distinguish between low-speed fire and no-fire events. The algorithm should have a sufficient safety margin against any misuse situation such as hammer blow, door slam, etc. This paper introduces several firing criteria such as acceleration. velocity and energy criteria that use physical value proportional to crash severity. We have made a simulation program by using Matlab/Simulink to implement the proposed algorithm. We have conducted an algorithm calibration by using real crash data for 2,500cc vehicle. The crash performance obtained by the simulation was verified through a pulse injection method. It turned out that the results satisfied the system requirements well.

  • PDF

Performance of PN Code Based Time Hopping Sequences in M-ary Ultra Wide Band Multiple Access Systems Using Equicorrelated Signal Sets (동일 상관 신호군을 이용하는 M-ary UWB 다원 접속 시스템에서 PN 부호 기반 시간 도약 시퀀스의 성능)

  • 양석철;신요안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10A
    • /
    • pp.816-829
    • /
    • 2003
  • In this paper, we evaluate the performance of PN (Pseudo Noise) code based time hopping sequences for M-ary UWB (Ultra Wide Band) multiple access systems using the equicorrelated signal sets. In particular, we consider two different types of M-ary UWB systems in UWB indoor wireless multipath channels: The first type of the systems (System #1) has identical symbol transmission rate regardless of the number of symbols M since the length of signal pulse train is fixed while M increases, and the second type of the systems (System #2) has the same bit transmission rate regardless of M since the length of signal pulse train is extended according to the increase of M. We compare the proposed systems with those using the ideal random time hopping sequence in terms of the symbol error rate performance. Simulation results show that the PN code based time hopping sequence achieves quite good performance which is favorably comparable to that of the ideal random sequence. Moreover, as M increases, we observe that System #2 shows better robustness against multiple access interference than System # 1.

Ring-type Heart Rate Sensor and Monitoring system for Sensor Network Application (센서 네트워크 응용을 위한 반지형 맥박센서와 모니터링 시스템)

  • Jang, In-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • As low power, low cost wireless communication technology like Bluetooth, Zigbee, RFID has been put to practical use together with the wellbeing trend, the concern about ubiquitous health care has been greatly increased and u-Health is becoming one of the most important application in the sensor network field. Especially, development of the medical services to be able to cope with a state of emergency for solitary senior citizens and the aged in silver town is very meaningful itself and their needs are also expected to continuously increase with a rapid increase in an aging population. In this paper we demonstrate the feasibility of extracting accurate heart rate variability (HRV) measurements from photoelectric plethysmography(PPG) signals gathered by a ring type pulse oximeter sensor attached to the finger. For this, we made 2 types of ring sensor, that is reflective and pervious type, and developed the remote monitoring system which is able to collect HR data from ring sensor, analyze and cope with a state of emergency.

Definition, Role and Method of Yinyang Pattern Differentiation (음양변증(陰陽辨證)의 정의와 기능 및 판별방법 연구)

  • Chi, Gyoo-yong;Park, Shin-hyung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.47-55
    • /
    • 2021
  • In order to ensure the fact that eight principle pattern differentiation is used clinically as a basic guideline for Korean medicine practice, the definition, role and method of yin-yang pattern differentiation with its case report were explored at first. Yinyang Pattern Differentiation is a method of discriminating human tendencies or morbidity based on the yin and yang characteristics expressed in living bodies. And yin and yang are the two contrasting characteristics and aspects of the interaction when certain physical conditions that have a lasting effect on the human physiological metabolic function are correlated with the morbidity. Specific methods of yinyang pattern differentiation can be divided into several types of yin and yang indicators. First, time and space factors like day and night, hot and cold seasons, above and below, topographical districts. Second, colors and pulse and their/or relative clearness and muddiness, hardness and softness, moving and resting. Third, diagnose yin and yang patterns through distinguishing the true and false of a fever and cold in an emergency phase such as increase of brain pressure and shock state. Fourth, general characteristics of the propensity and constitution of a subject such as body type, speech, behavior, and physiological metabolism. And for clinical use, these were summarized again as a symptom indicators of physical signs and color, pulse, tongue and questionnaire indicators of propensity, body type, and space-time characteristics. Conclusively, it was confirmed that yinyang pattern differentiation has its own diagnostic significance which is distinct from exterior-interior, cold-heat and deficiency-excess pattern differentiation.

Evaluation of vibration damping rate performance according to polymer mixing rate of polymer mixed mortar through ultrasonic pulse analysis (초음파 펄스 분석을 통한 폴리머 혼입 모르타르의 폴리머 혼입률에 따른 진동감쇠율 성능 평가)

  • Jeong, Min-Goo;Jang, Jong-Min;Lee, Gwang-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.71-72
    • /
    • 2022
  • In this paper, the performance evaluation of the vibration damping ratio according to the polymer mixing ratio of the polymer modified mortar used as the floor finishing material of the apartment building structure was evaluated. To compare the vibration damping rate, ordinary potland cement (OPC) mortar and polymer modified mortar (PMM) were prepared. In addition, the mixed polymer was mixed with Styrene Butadiene Rubber (SBR) liquid polymer with a solid content of about 49%. Accordingly, the W/C of the test specimen was adjusted and compounded, and the experiment was conducted by mixing 5 types of the test specimen: OPC-60, PMM-5%, PMM-10%, PMM-15%, and PMM-20%. In addition, in order to adjust the W/C of the specimen, the fluidity of each specimen was set as 210 (±5) mm. The specimens measured density and flow in fresh mortar and after curing for 28 days, flexural strength, compressive strength and ultrasonic pulse were measured. The attenuation rate was shown. The experimental results showed that the density increased according to the mixing of the polymer, the flexural strength increased as the mixing rate of the polymer increased, and the compressive strength was decreased. In addition, it was shown that the vibration damping rate increases with the increase in the amount of polymer incorporated.

  • PDF

A Model for Liquid Circulation Velocity in Airlift Reactors (공기부양반응기 내에서의 액체순환속도를 위한 모델)

  • Keun Ho Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.446-455
    • /
    • 2023
  • A mathematical model for predicting the liquid circulation velocity in an airlift reactor was developed based on the mechanical energy balance of the fluid circulation loop. The model considered the energy loss due to a 90° turn, the energy loss due to friction, and the energy loss due to the change in cross-sectional area at each part of the reactor. The model that separately considered the loss coefficients related to friction, direction change, and cross-sectional area change was able to predict the liquid circulation velocity better than the previous model using lumped parameters. The liquid circulation velocity was measured by the tracer pulse method. Most of our experimental results obtained in external-loop airlift reactors, which had the top and bottom connecting pipes, as well as other investigators' results obtained in various types of airlift reactors, were well predicted by the developed model with an error within 20%. Useful empirical equations for the loss coefficient related to the 90° turn of the circulating fluid were obtained in external and internal-loop airlift reactors and used to predict the liquid circulation velocity.

New Communication Method using Pulse Width Information for Power Converter Parallel Operation (전력변환기 병렬운전을 위한 펄스폭 정보를 이용한 새로운 통신방식)

  • Dong-Whan Kim;Seong-Cheol Choi;Tuan-Vu Le;Sung-Jun Park;Seong-Mi Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1097-1108
    • /
    • 2023
  • Recently, demand for technology for energy economy and stable supply is increasing due to the increase in power demand of loads. The amount of DC power generation using new and renewable energy is noticeably increasing, and the use of DC power supplies is also increasing due to the increase in electric vehicles and digital loads. During parallel operation to increase the capacity of the power converter, the module bus method or the method using Can communication and serial communication has significant difficulties in smooth operation due to communication time delay for information sharing. Synchronization of information sharing of each power converter is essential for smooth parallel operation, and minimization of communication time delay is urgently needed as a way to overcome this problem. In this paper, a new communication method using pulse width information is proposed as a communication method specialized for parallel operation of power converters to compensate for the disadvantage of communication transmission delay in the existing system. The proposed communication method has the advantage of being easily implemented using the PWM and Capture function of the microcomputer. In addition, the DC/DC converter for DC distribution was verified through simulation and experiment, and it has the advantage of easy capacity expansion when applied to parallel operation of various types of power converters as well as DC/DC converters.

A Study on the Clinical Characteristics of 4-Constitution Groups in 8-Constitution Medicine (8체질의학에서 목$\cdot$$\cdot$$\cdot$수 4체질군의 임상적 특징에 대한 연구)

  • Lee Sang-Beom;Choi Kyung-Mee;Park Young-Jae;Park Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.26 no.3 s.63
    • /
    • pp.80-97
    • /
    • 2005
  • Backgrounds : In recent years there has teen renewed interest in the importance of 8-constitution medicine as evidenced by growth of research in this field. Although diagnosis by 8-constitution depends on pulse types, it still is subjective and thus could be insignificant. Therefore, diagnosis based on objective characteristics is essential. Objectives : The purpose of this study was to find objective characteristics of the 4-constitution groups {木(Mok; hepatonia, cholecystonia), {土(To; pancreotonia, gastrotonia), {金(Gum; pulmotonia, colonotonia), {水(Soo; renotonia, vesicotonia)} in 8-constitution for further diagnosis and therapy. Also, some significant clinical tendencies of 4-constitution groups were studied. Methods : From Nov. 2001 to Apr. 2004, data were collected through a questionnaire given to 720 patients who were classified into one of 8 constitutions according to their pulse types and their responses to constitution-based acupuncture therapy. The questionnaire was composed of 80 items which were about personality, physical shape, habit, physiological and pathological symptoms, response to drugs, favorites and responses to various foods. The data were statistically analyzed by cross-tabulation and one-way analysis of variance, and SPSS V10.0.7PC was used. Results : The results are summarized as follows: 1) Among participants, proportions of hepatotonia, pancreotonia, and cholecystotonia were higher than those of vesicotonia, pulmotonia, colonotonia, renotonia, grstrotonia. 2) 52 items of 80 variances showed significant differences by gender, 3) 13 items were highly correlated with 4-constitution groups in males, and 26 items in fremales. 4) 22 items showed significant group differences among 4-constitution groups in males, and 41 items in females. Also, for each item 4-constitution groups were sorted according to their means, so that the constitutional tendencies were objectively figured out by personality, shape, habit, physiological and pathological symptoms, response to drugs, favorites and responses to foods. Conclusions : Most clinical characteristics of 4-constitution groups found in this study coincided with those from the previous ones in this fold. Thus, classifying patients into one of the 4-constitution groups based on significant objective characteristics is of great benefit to diagnosis and therapy. further study should be followed to improve proper therapy for each constitution.

  • PDF

Assessment of Ni Catalyst Properties for Removal of O2 and CO Impurity in Inert Gas (불활성 가스의 O2와 CO 불순물 제거를 위한 Ni 촉매의 물성 평가)

  • Kim, Kwangbae;Jin, Saera;Kim, Eunseok;Lim, Yesol;Lee, Hyunjun;Kim, Seonghoon;Noh, Yunyoung;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.588-595
    • /
    • 2020
  • This study examined the catalytic property of Ni-catalyst used in the gas purifying process to manufacture inert gases of N2 and Ar with high-purity over 9N for semiconductor industrial applications. Two types of Ni-catalysts with a cylindrical shape (C1) and churros shape structure (C2) were compared for the assessment. Optical microscopy and FESEM were used to analyze the shape and microstructure of the Ni-catalyst. EDS, XRD, and micro-Raman characterization were performed to examine the composition and properties. BET and Pulse Titration analyses were conducted to check the surface area and catalytic property of the Ni-catalyst. From the composition analysis results, C1 contained a relatively large amount of graphite as an impurity, and C2 contained higher Ni contents than C1. From specific surface area analysis, the specific surface area of C2 was approximately 1.69 times larger than that of C1. From catalytic property analysis, outstanding performance in O2 and CO impurity removal was observed at room temperature. Therefore, C2, having low-impurity and large specific surface area, is a suitable catalyst for the high-purity inert gas process in the semiconductor industry because of its outstanding performance in O2 and CO impurity removal at room temperature.