• 제목/요약/키워드: Pulse transformers

검색결과 70건 처리시간 0.02초

변압기의 고장검출을 위한 유중 코로나 특성 연구 (Transformer diagnosis using characteristics of corona in Oil)

  • 권태원;곽희로;김재철;김응상;박민규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.65-70
    • /
    • 1989
  • This paper presents resarch results on the use of a corona detector and a pulse counter in order to diagnose for oil transformers. Using these experimental apparatus, tests were carried out on a typical transformer oil containing different carbonized paper and various moisture contents to measure the picocoulomb val-ues and pulse count. Through the result of this study it was found that the picocoulomb values and pulse count of corona were depended on the getting stained in transformer oil. The amplitude of the partial discharge amount and the number of pulse were decreased up to 70 [。c] and then was increased as the oil temperature goes up. It was concluded that the determinati-on level for diagnosis of oil transform-er was taken into account the temperatu-er of transformer oil, The use of pulse counter method, which have been taken the same property of voltage and temperature variation for the corona measurement mothod, considera-bly increase insulator avilability.

  • PDF

전류 고조파에 기인하는 변압기 손실 해석 (Power Loss Analysis of Transformer Caused By Current Harmonics)

  • 장승용;한상훈;최재호
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.34-41
    • /
    • 2016
  • This study investigates transformer losses caused by current harmonics. Electrical transformers are designed to work under sinusoidal voltage and current waves at a rated frequency. Recently, various nonlinear loads, such as power electronic converters, are connected to a power system; these converters generate current harmonics. Current harmonics increase power loss in transformers, which results in several problems, including temperature increase of the transformer and insulation damage. These problems will eventually shorten the operational life of the transformer. In this study, different types of losses caused by current harmonics in three-phase transformers are studied under linear and nonlinear load conditions. Linear loads are simulated and experimented on using pure resistance load, whereas nonlinear loads are simulated and experimented on using a three-phase twelve-pulse thyristor full-bridge rectifier. The different types of losses in three-phase transformers are evaluated analytically through the experimental result and simulation in PSiM.

펄스파워전원용 고전압 펄스변압기 (High voltage Pulse Transformer for Pulsed Power Supply)

  • 김종해;구치욱;최영욱;이홍식;임근희;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1755-1757
    • /
    • 1998
  • Pulse transformers have been developed to apply for pulsed power technology as an alternative of a Marx generator. To obtain repetitive pulsed power generation, it is necessary to observe the rising time of output of pulse transformer. In this paper, using the equivalent circuit, The rising wave of output of pulse transformer is simulated for various input wave by using the Electromagnetic transient program(EMTP).

  • PDF

몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술 (Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers)

  • 정광석;박대원;차현규;차상욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

두 개의 변압기를 이용한 전류불균형 개선 하프브리지 LLC 공진형 컨버터 (Current Unbalance Improved Half-bridge LLC Resonant Converter using the Two Transformers)

  • 유두희;정강률
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.497-507
    • /
    • 2010
  • 본 논문은 상이한 누설인덕턴스를 가진 두 개의 변압기를 이용하여 전류불균형을 개선한 하프브리지 LLC 공진형 컨버터를 제안한다. 제안된 컨버터는 변압기의 누설인덕턴스와 자화인덕턴스 및 공진커패시턴스를 이용하여 공진하고, 넓은 부하영역을 가지며, 경부하에서도 영전압스위칭 조건을 만족한다. 직/병렬로 연결된 두 개의 변압기는 동작모드에 따라 변압기 또는 공진인덕턴스로써 교대로 동작하고, 변압기 2차측에는 누설인덕턴스를 이용하므로 별도의 출력 필터인덕턴스가 필요하지 않다. 또한 제안된 컨버터는 두 변압기의 상이한 누설인덕턴스와 하프브리지 스위치의 비대칭 펄스폭변조를 이용하여 2차측 정류다이오드의 전류불균형 문제를 개선한다. 본 논문에서는 제안된 컨버터의 동작원리를 모드별로 설명하고 프로토타입 컨버터의 설계 예를 제시한다. 제안된 컨버터의 우수한 성능을 입증하기 위하여 설계된 프로토타입의 회로파라미터로써 프로토타입 컨버터를 제작하고 실험하였다. 제안된 컨버터의 우수한 성능을 실험결과를 통하여 보인다.

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

수백 kV급 공심형 펄스 변압기 개발 (Development of several hundred kV Air Core pulse transformer)

  • 김성철;박성수;김상희;허훈;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2132-2135
    • /
    • 2005
  • Cylindrical type air core pulse transformers capable of passing high voltage and energy pulse waveforms with high efficiency and low distortion require a much more delicate design balance of physical dimensions and electrical parameters than iron or ferrite core units. The structure of an air core high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent breakdown between transformer windings. Since the thickness of the windings in spiral type is on the order of sub-millimeter, field enhancement at the edge of the windings is very high. It is, therefore, important to find proper electrical insulation Parameter to make the system compact. Several shapes of the winding are considered for air core pulse transformer development. In this paper, we are described design procedure, parameters measure and experiment results of air core type HV pulse transformer.

  • PDF

개선된 초음파방법에 의한 변압기내 부분방전 위치 검출 (Improved Ultrasonic Method for Locating Partial Discharges in Transformers)

  • 곽희로;김재철;조국희;한민구;임주일;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.252-257
    • /
    • 1988
  • This paper discribes an improved technique for locating partial discharge sites within operating transformers by ultrasonic method which utilizes the different travel times of the electrical and ultrasonic signals produced by partial discharges to determine the location of the sources. The technique was to develope the measurement system based on the enhancement of the acoustic emission signals using signal square, circuit to improve the detectable sensitivity and reliability. Also an ultrasonic pulse generator was designed and made to transmit periodically pulses equivalent to pratial discharges and to check the good performance of the system, echo effects and self-diagnosis. Through the laboratory work, it was confirmed that the system and the generator can be used satisfactorily for diagnosing power transformers and for studying echo effects and self-diagnosis of the system.

  • PDF

펄스 방전을 위한 고전압 스위치 설계 (Design of High Voltage Switch for Pulse Discharging)

  • 아피아 기드온 니모;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.361-362
    • /
    • 2016
  • Presented in this paper is the design of a high voltage switch module made up of MOSFETs, pulse transformers and their gate driver circuits compactly fitted onto a single PCB module. The ease by which the switch modules can be configured (series stacking and/or parallel stacking) to meet future load variations allows for flexible operation of this design. In addition, the detailed implementation of the gate driver circuit for reliable and easier switch synchronization is also described in this paper. The stored energy in the capacitor bank of a 15kV, 4.5kJ/s peak power capacitor charger was discharged using the developed high voltage switch, and by experimental results, the operation of the proposed circuit was verified to be effectively used as a switch for pulse discharging.

  • PDF

A Study on the Design of a Pulse-Width Modulation DC/DC Power Converter

  • Lho, Young-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권3호
    • /
    • pp.201-205
    • /
    • 2010
  • DC/DC Switching power converters are commonly used to generate regulated DC output voltages with high-power efficiencies from different DC input sources. A switching converter utilizes one or more energy storage elements such as capacitors, or transformers to efficiently transfer energy from the input to the output at periodic intervals. The fundamental boost converter studied here consists of a power metal-oxide semiconductor field effect transistor switch, an inductor, a capacitor, a diode, and a pulse-width modulation circuit with oscillator, amplifier, and comparator. A buck converter containing a switched-mode power supply is also studied. In this paper, the electrical characteristics of DC/DC power converters are simulated by simulation program with integrated circuit emphasis (SPICE). Furthermore, power efficiency was analyzed based on the specifications of each component.