• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.026 seconds

Estimation of the hydraulic conductivity profile in fractured rocks using the borehole flowmeter test (시추공 유속 검층을 이용한 암반 대수층의 수리전도도 분포 산정)

  • 구민호;차장환
    • The Journal of Engineering Geology
    • /
    • v.12 no.3
    • /
    • pp.257-271
    • /
    • 2002
  • The vertical distribution of hydraulic conductivity of 3 boreholes located at Kongju National University was estimated by the ambient flow and the pump-induced flow measurements using a heat-pulse flowmeter. The ambient flow measurements showed that a great amount of groundwater (1~2 m$^3$/day) flowed in the boreholes through the conductive fractures. The analyzed conductivity profiles we similar to those of the packer test performed for the same boreholes. The conductive fractures in which the differential net flow changed greatly could be identified by the BIPS logging. The water-quality logging data showed that quality of groundwater changed abruptly at some depths of the boreholes. This change in water quality can be attributed to the presence of conductive fractures that have resulted in the mixing of groundwater of different quality flowing in different fracture channels. However, compared to the flowmeter test, the water-quality logging showed low capability in identifying locations of conductive fractures.

The Effect of Rhythmical Exercise Program Period on Physiological Improvements in the Elderly (율동적 근육운동 프로그램의 적용 기간에 따른 노인의 신체기능 변화)

  • Han Ae-Kyung;Won Jong-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.301-315
    • /
    • 2000
  • The main purpose of this study was to evaluate the effect of a Rhythmical Exercise Program(REP) on physiological functions such as muscle strength, blood pressure, pulse, flexibility and body fat in the elderly. The research employed a non-equivalent control group pre-post test quasi experimental design. REP consisted of 45 minutes of dance, 3 times a week for 10 weeks. The formulated hypothesis were examined using the non-parametric statistics; Wilcoxon Signed rank sum test and Mann-Whitney test. The results are as follows; 1. The upper muscle strength and lower muscle strength of the experimental group were significantly higher than those of the control group following the REP(P<.0 5). And the Period of REP affected the muscle strength; the longer the exercise period, the stronger the muscle strength became. 2. The systolic blood pressure of the experimental group was significantly lower than that of the control group following the REP(p<.05). But there was no significant difference in the diastolic blood pressure between the experimental and control groups. The period of REP affected only systolic pressure; the longer the exercise period, the lower the systolic pressure became. 3. There was no significant difference in heart rate between the experimental and control groups, following the exercise period. 4. The flexibility of the experimental group was significantly higher than those of the control group following the REP(p<.01). And the period of REP affected flexibility; the longer the exercise period, the higher the flexibility(p<.05) became. 5. There was no significant difference of body fat between the experimental and control groups. The body fat of the experimental groups was significantly lower only 10 weeks after exercise(p<.01). Based on these results, it is suggested that rhythmical exercise program improves muscle strength, systolic pressure, and flexibility in the elderly.

  • PDF

The Effects of Music Therapy on the Preoperative Anxiety of Surgical Patients (음악요법이 수술환자의 수술전 불안에 미치는 효과)

  • Park, Sung Hee;Park, Kyung Sook
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.654-665
    • /
    • 2000
  • The purpose of this study was to elucidate the effects of music therapy on the preoperative anxiety of surgerial patients. The research design was a nonequivalent control, group non-synch-ronized design. The data were collected during the period from January 4 to March 17, 1999 at C-University hospital in Seoul. The subjects were sixty patients who had surgery under general anesthesia and had undergone laparotomy. They were assigned to two groups, thirty to the experimental group and thirty to the control group. They also did not have any complication, were alert enough to be interviewed and agreed willingly to participate in this study. The tool of Trait Anxiety Inventory was used to measure trait-anxiety on all patients and the Visual Analogue Scale(VAS) was used to measure state-anxiety on all patients. And systolic and diastolic blood pressure, pulse rate, and blood sugar levels were collected a the day before surgery and the preoperative period. The experimental group received music therapy with self-selected music tapes after choosing from a Music Preference Questionnaire, while the control group didn't receive music therapy. Data were analyzed by ${\chi}^2$-test, t-test, paired t-test. The results of this study are summarized as follows: 1. The preoperative state anxiety of the experimental group was re-markably lower than that of the control group. 2. Decreasing rate in the vital signs of the experimental group was remarkably lower than that of the control group. 3. The preoperative blood sugar of the experimental group was remarkably lower than that of the control group. According to these results, Music Therapy can be regarded as an effective nursing intervention that relieves preoperative anxiety of surgical patients and helper stabilize vital signs. From this study, the following recommendations can be made: 1. In order to decrease surgical patient's preoperative anxiety, I suggest the nursing intervention should go side by side with music therapy.

  • PDF

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.

An Empirical Estimation Procedure of Concrete Compressive Strength Based on the In-Situ Nondestructive Tests Result of the Existing Bridges (공용중 교량 비파괴시험 결과에 기반한 경험적 콘크리트 압축강도 추정방법의 제안)

  • Oh, Hong-Seob;Oh, Kwang-Chin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.111-119
    • /
    • 2016
  • Rebound hammer test, SonReb method and concrete core test are most useful testing methods for estimate the concrete compressive strength of deteriorated concrete structures. But the accuracy of the NDE results on the existing structures could be reduced by the effects of the uncertainty of nondestructive test methods, material effects by aging and carbonation, and mechanical damage by drilling of core. In this study, empirical procedure for verifying the in-situ compressive strength of concrete is suggested through the probabilistic analysis on the 268 data of rebound and ultra-pulse velocity and core strengths obtained from 106 bridges. To enhance the accuracy of predicted concrete strength, the coefficients of core strength, and surface hardness caused by ageing or carbonation was adopted. From the results, the proposed equation by KISTEC and the estimation procedures proposed by authors is reliable than previously suggested equation and correction coefficient.

Case Report of Generalized Anxiety Disorder Treated with Guibiondamtang-gami (범불안장애를 호소하는 귀비온담탕 가미방 치험 1례)

  • Yang, Seung-bo;Kim, Yeon-jin;Lee, Hyung-min;Lee, Hyun-joong;Cho, Seung-yeon;Park, Seong-uk;Park, Jung-mi;Ko, Chang-nam
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.361-367
    • /
    • 2016
  • Objective: This clinical study reports on the effect of traditional Korean medicine on a patient with generalized anxiety disorder.Method: A patient who suffered from generalized anxiety disorder was treated with herbal medicine (Guibiondamtang-gami), acupuncture, moxibustion, and pharmacopuncture. We assessed the changes of anxiety-related symptoms with the state-trait anxiety inventory (STAI) score, the Beck anxiety inventory (BAI) score, a heart rate variability (HRV) test, and a second derivative of photoplethymogram waveform (SDPTG) test.Results: After taking Guibiondamtang-gami for 22 days, the patient’s STAI score, BAI score, and LF/HF (low-frequency/high-frequency heart rate variability) ratio decreased, while the differential pulse wave index and stress power in the SDPTG test increased.Conclusion: This clinical case study has demonstrated that traditional Korean medicine may be an effective option for treating generalized anxiety disorder.

The Efect of Cutaneus Stimulation on AV Fistula Puncture Pain of Hemodialysis Patients (피부자극이 혈액투석환자의 동정맥루 천자시 동통감소에 미치는 영향)

  • Park, Jeong-Sook
    • The Korean Nurse
    • /
    • v.33 no.1
    • /
    • pp.37-51
    • /
    • 1994
  • The cutaneous stimulation is an independent nursing intervention used in various painful conditions, and is explained by gate control theory. This study was aimed at identifying the effect of cutaneous stimulation on reduction of arteriovenous fistula puncture pain of hemodialysis patients. One group repeated measurement post test research was designed. Forty-five hemodialysis patients who received arteriovenous fistula puncture regulary in hemodialysis units of an attacted D hospital to K university have been studied from August 16 to 21, 1993. First the arteriovenous fistula puncture pain of control period was measured, and then the arteriovenous fistula puncture pain of experimental period(with cutaneous stimulation) was measured. The instrument used for this study were visual analogue pain scale as subjective pain measurement, objective pain behavior checklist and Spielberger's Trait Anxiety Inventory as intervening variables. Analysis of data was done by use of paired t-test, t-test, ANOVA and Perarson correlation coefficient. The results of this study were summarized as follows; 1) The first hypothesis that the subjective pain score of arteriovenous fistula puncture pain in experimental period(with cutaneous stimulation) will be lower than in control period was partly supported. The subjective pain score of arterial line was rejected(paired t=-0.28, p=0.77) and the subjective pain score of venous line was supported(paired t=2.61, p=0.01). 2) The second hypothesis that the objective pain behavior score of arteriovenous fistula pain in experimental period(with cutaneous stimulation) will be lower than in control period was rejected(arterial line paired t=-0.45, p=0.65; venous line paired t=-0.36, p=0.72). 3) The third hypothesis that the cardiopulmonary signs of arteriovenous fistula puncture pain in experimental period(with cutaneous stimulation) will be lower than in control period was rejected(pulse paired t=-0.8, p=0.42; systolic BP paired t=0.98, p=0.33; diastolic BP paired t=0.43, p=0.66). Further experimental studies with simple intravenous injection patients will be recommended in order to identify the effect of cutaneous stimulation.

  • PDF

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

Suppression of stray electrons in the negative ion accelerator of CRAFT NNBI test facility

  • Yuwen Yang ;Jianglong Wei ;Junwei Xie ;Yuming Gu;Yahong Xie ;Chundong Hu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.939-946
    • /
    • 2023
  • Comprehensive Research Facility for Fusion Technology (CRAFT) is an integration of different demonstrating or testing facilities, which aim to develop the critical technology or composition system towards the fusion reactor. Due to the importance and challenge of the negative ion based neutral beam injection (NNBI), a NNBI test facility is included in the framework of CRAFT. The initial object of CRAFT NNBI test facility is to obtain a H0 beam power of 2 MW at the energy of 200-400 keV for the pulse duration of 100 s. Inside the negative ion accelerator of NNBI system, the interactions of the negative ions with the background gas and electrodes can generate abundant stray electrons. The stray electrons can be further accelerated and dumped on the electrodes or eject from the accelerator. The stray electrons, including the ejecting electrons, cause the unwanted particle and heat flux onto the electrodes and the inner components of beamline (especially the temperature sensitive cryopump). The suppression of the stray electrons from the CRAFT accelerator is carried out via a series of design and simulation works. The paper focuses the influence of different magnetic field configurations on the stray electrons and the character of the ejecting electrons.

Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis

  • Paula Lambert;Sergio Augusto Quevedo Miguens Jr;Caroline Solda;Juliana Tomaz Sganzerla;Leandro Azambuja Reichert;Carlos Estrela;Fernando Branco Barletta
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.48.1-48.11
    • /
    • 2020
  • Objectives: This systematic review aimed to identify mean oxygen saturation values (SpO2) using pulse oximetry in permanent maxillary anterior teeth. Materials and Methods: The MEDLINE, Scientific Electronic Library Online, Cochrane Central Register of Controlled Trials, EMBASE, and Literatura Latino Americana em Ciências da Saúde electronic databases were searched. Combinations and variations of "oximetry" AND "dental pulp test" were used as search terms. Studies reporting means and standard deviations of SpO2 values were included. Two reviewers independently extracted data following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Heterogeneity was assessed using the I2 statistic, and all analyses were performed using R software. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool and the Newcastle-Ottawa scale. Results: Of the 251 studies identified, 19 met the eligibility criteria and were included (total sample, 4,541 teeth). In the meta-analysis, the mean SpO2 values were 84.94% (95% confidence interval [CI], 84.85%-85.04%) for the central incisors, 89.29% (95% CI, 89.22%-89.35%) for the lateral incisors, and 89.20% (95% CI, 89.05%-89.34%) for the canines. The studies were predominantly low-quality due to the high risk of bias associated with the index test, unclear risk regarding patient selection, and concerns about outcome assessment. Conclusions: Although most studies were low-quality, the oxygen saturation levels in normal pulp could be established (minimum saturation, 77.52%). Despite the risk of bias of the included studies, the reference values reported herein are clinically relevant for assessments of changes in pulp status.