• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.032 seconds

Computerized pulse diagnosis system (컴퓨터 맥진시스템)

  • Lee, Ho-Jae;Huh, Woong
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.81-90
    • /
    • 1996
  • In this paper, we implemented a computerized pulse diagnosis system for the developement of pulse diagnosis algorithms and the generalization of the pulse diagnosis. The system consists of the hardware and software. The hardware detects pulse waves and inputs the waves into the computer system, while the software not only manages and analyzes the input pulse wave data but also privides the database. In order to clinically test the developed pulse diagnosis system, we applied the carotid-radial pulse diagnosis algorithm to the system. As the results, it is found that the genralizatio of the pulse diagnosis is possible.

  • PDF

A Study on the Applicability of the Hydraulic Test Method Performed at an underground Research Facility in Crystalline Rock (결정질 암반내 지하연구시설에서 수행한 현장수리시험법 적용성 연구)

  • Park, Kyung-Woo;Ko, Nak-Yeol;Ji, Sung-Hoon
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.121-131
    • /
    • 2020
  • In this paper, the transmissivities obtained from the pulse test, the slug test and the constant head test were compared each other to assess an applicability and a reliability of the hydrogeological test method, which are commonly used to derive the hydrogeological properties of a crystalline rock at un underground research facility. When comparing the results of the pulse test and the slug test, the transmissivities were very similar in the entire test section of the medium. However, there was a little discrepancy in the results in the areas where the permeability is relatively high. The results of the constant head test on the same section showed the lower transmissivity than the results of the pulse test and the slug test on the highly permeable section. This difference in permeability was considered to be due to the difference in the radius of the hydraulic effect applied in each hydraulic test. When the heterogenetic distribution of fracture affects the hydrogeological properties on crystalline rock, it is believed that the hydrogeological characteristics can be explained through a constant head test or a constant flow rate test with a large hydraulic effective radius, as well as a pulse and a slug test that can identify hydrogeological properties in a relatively short time.

Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator

  • Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Hong, Yong-Ju;Koh, Deuk-Yong;Yeom, Hankil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.50-53
    • /
    • 2012
  • This paper describes experimental study on GM-type pulse tube refrigerator (PTR). In a PTR, the pulse tube is only filled with working gas and there exists secondary flow due to a large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus, the cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube refrigerator is fabricated and tested. The cooing performance of the fabricated PTR is measured as varying cold-head orientation angle and the results are used as reference data. Then, we divided interior space of pulse tube into three segments, and fixed the various size of screen mesh at interface of each segment to suppress the performance degradation due to secondary flow. For various configuration of pulse tube, no-load test and heat load test are carried out with the fixed experimental condition of charging pressure, operating frequency and orifice valve turns. From experimental results, the fine screen mesh shows the effective suppression of performance degradation for the large orientation angle, but the use of screen mesh cause the loss of cooling capacity rather than the case of no insertion into pulse tube. It should be compromised whether the use of screen mesh in consideration of the installation limitation of a GM-type pulse tube refrigerator.

A Study on Pulse Pattern Using Ultrasonic Device (초음파기기를 이용한 맥상(脈象) 연구)

  • Kim, Hee Young;Park, Jeongbin;Keum, Yujeong;Yeo, Inkeum;Eom, Dongmyung;Song, Jichung
    • Journal of Korean Medical classics
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

A Study on the Statistical Distribution of Rebound Number and Ultrasonic Pulse Velocity in RC and PSC Concrete Structures (RC 및 PSC 콘크리트에서 반발도 및 초음파 속도의 변화에 대한 연구)

  • Sa, Min-Hyung;Yoon, Young-Geun;Lee, In-Bok;Woo, In-Sung;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.53-58
    • /
    • 2017
  • The rebound hammer test and the measurement of ultrasonic pulse velocity(UPV) have been widely used for the physical properties & condition evaluation of reinforced & prestressed concrete structures for a long time, but the acoustoelastic effects by the prestressing in the prestressed concrete structures on the rebound number and ultrasonic pulse velocity have not been studied clearly. Therefore, this study investigated the data distribution of the rebound numbers and ultrasonic pulse velocities in reinforced and prestressed concrete slabs of $3000{\times}3000mm$ with a thickness of 250 mm. Also, the Kolmogorov-Smirnov goodness-of-fit test was done in order to identify statistical consistency and reliability. The statistical analysis results show that the rebound number and ultrasonic pulse velocities increased about 1.9% and 2.5%, respectively when prestressing was applied. As expected, the UPV shows better statistical reliability and potential for in situ evaluation than the RB because the RB are more sensitive to testing posture, surface condition, temperature and humidity so on. The experimental data in this study can be used for the condition assessment of reinforced and prestressed concrete structures by the rebound number and ultrasonic pulse velocity.

The Effect of Guided Imagery on Blood Pressure and Pulse Rate - In Nursing Students - (지시적 심상요법이 혈압과 맥박에 미치는 효과 - 간호대학생을 대상으로 -)

  • Choi, Eun-Ok;Lee, Dong-Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.5 no.2
    • /
    • pp.31-39
    • /
    • 2003
  • The purpose of this study was to test the effect of guided imagery on blood pressure and pulse rate. The subjects were thirty-nine nursing students in I university located in Busan, Korea To enhance the effect of treatment, they were trained getting themselves absorbed in guided imagery on three different occasions before the study. Actually in the study, the subjects were given instruction in Mason's guided imagery for 19 minutes and 58 seconds. Blood pressure and pulse rate were measured before and after guided imagery application. The data were analyzed through paired t-test. The Results were as follows : 1) There was a significant decrease in systolic blood pressure after the use of guided imagery. 2) There was no significant decrease in diastolic blood pressure after the use of guided imagery. 3) There was a significant decrease in pulse rate after the use of guided imagery. These results indicate that guided imagery is a helpful technique for decreasing blood pressure and pulse rate, which are increased in stress condition.

  • PDF

Design, Test and Evaluation on the PSD with Thermal Barrier Type for Subscale Dual Pulse Rocket Motor (격막형 PSD를 적용한 소형 추진기관 설계 및 시험평가)

  • Kim, Jinyong;Kwon, Taeha;Lee, Wonbok;Cho, Wonman;Lee, Bangeop;Yun, Namgyun;Rhee, Youngwoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.6
    • /
    • pp.82-87
    • /
    • 2014
  • Dual pulse rocket motor has a rocket motor with different pulse grains divided by a pulse separation device such as a fragile bulkhead or a thermal barrier type. It distributes thrust energy very effectively via pulse separation device to improve range and terminal velocity of a missile. This paper contains the thermal barrier design and experimental analysis through ground firing tests of small dual pulse motors. The results will be applied to the design, test and evaluation of the scale up dual pulse rocket motor.

The Characteristic Analysis of SRM Dirven by Single-pulse Mode Considering the Voltage Ripple of DC Linke (SRM의 DC linke 전압리플을 고려한 단일 펄스 구동 방식의 특성 해석)

  • Lee, Sung-Gu;Jung, Dae-Sung;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1976-1980
    • /
    • 2008
  • This paper deals the characteristic analysis of Switched Reluctance Motor(SRM) driven by single-pulse mode considering dc link voltage ripple. Two dimensional time-stepped Finite Element Method(FEM) is used to analyze the characteristic of SRM driven by single-pulse mode with dc link voltage ripple. The analysis results is verified by experimental test.

Application of Plackett-Burman model in welding experiments : effects of welding parameters on bead shape in Cu-Ni PULSE MIG process (PLACKETT-BURMAN MODEL을 이용한 Cu-Ni합금의 PULSE MIG 용접 변수해석)

  • 문영훈;이기학;허성도
    • Journal of Welding and Joining
    • /
    • v.5 no.4
    • /
    • pp.47-53
    • /
    • 1987
  • The purpose of this study is to reexamine our test method in the light ofstatistical methods for data interpretation. Our trial to apply Plackett-Burman statistical model in multifactorial welding experiments shows that is saves much time and cost and extracts very accurate results. In this study, the parametric effects of bead shape on pulse MIG process in Cu-Ni alloy are investigated for verifying our trial.

  • PDF

Study on the Setting time of Concrete Using Ultrasonic Test (초음파법에 의한 콘크리트 응결시간 측정에 관한 연구)

  • 구본창;강민호;이대근;김종우;하재담;박석균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.707-711
    • /
    • 1998
  • Ultrasonic test usually was used for defect detection, crack depth measurements and strength estimation of hardened concrete. The essence of the pulse velocity method is that the transition time of an ultrasonic longitudinal pulse is measured in concrete. Ultrasonic velocity was propagated to the age of concrete, made a radical change at that time when concrete was setted. This study which monitored the change in a concrete by ultrasonic test was performed to estimate initial setting and final setting.

  • PDF