• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.035 seconds

The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

  • Prasetyono, Theddeus O.H.;Adianto, Senja
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.505-509
    • /
    • 2013
  • Background The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. Methods An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. Results The mean times from the vessel clamping until the saturation became undetectable were $20.19{\pm}2.13$ seconds and $74.91{\pm}10.57$ seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was $34.5{\pm}11.72$ minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

Compressive Strength Estimation Technique of Underwater Concrete Structures using Both Rebound Hardness and Ultrasonic Pulse Velocity Values (반발경도와 초음파속도를 이용한 수중 콘크리트 구조물의 압축강도 예측 기술)

  • Shin, Eun-Seok;Lee, Ji-Sung;Park, Seung-Hee;Han, Sang-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.118-125
    • /
    • 2014
  • As the earth's current global warming has caused elevation of sea water temperature, size of storms is foreseen to increase and consequently large damages on port facilities are to be expected. In addition, due to the improved processing efficiency of port cargo volume and increasing necessity for construction of eco-friendly port, demands for various forms of port facilities are anticipated. In this study, two kinds of nondestructive evaluation (NDE) techniques (rebound hardness and ultrasonic pulse velocity methods) are investigated for the effective maintenance of smart green harbor system. A new methodology to estimate the underwater concrete strengths is proposed and its feasibility is verified throughout a series of experimental works.

Physiological Parameters Related to Health of The Elderly (노인의 건강관련 생리적 지수에 관한 연구)

  • Kim Jong Im;So Hee Young;Kim Hyun Li
    • Journal of Korean Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.271-280
    • /
    • 2000
  • The purpose of this study was to identify the health status of elderly. Subjects were 132 older people who live in home and institution located Taejon metropolitan city. Data were collected from May 1997 to April 1998. To obtain data about health status of elderly. pulse, respiration, systolic and diastolic blood pressure. grip strength. pinch pressure. flexibility, arm circumference. triceps skin fold thickness were measured. Data were analyzed for frequency. percentage. t-test using SPSS pc+ program. The results were as follows: 1. $74.4\%$ of subjects was perceived as 'good' in their health status. 2. Mean pulse, mean respiration, systolic and diastolic blood pressure were with in normal limits. There were no statistical differences between men and women in pulse, respiration, systolic and diastolic pressure. 3. Left and right grip strength were 24.89 psi and 25.23psi. The grip strength in men was higher than that of women. It showed statistically difference between men and women in grip strength. 4. Left and right pinch pressure were 7 pound and 7.32 pound. There was statistically difference of pinch pressure between men and women. 5. left flexibility was better than right flexibility of subjects. There was no statistically significant difference between men and women in flexibility. 6. Arm circumference was 24.96cm and there was no statistically significant difference between men and women. 7. Mean skin fold thickness was 12.83 em. Skin fold thickness in men was lower than that of women. It showed statistically difference between men and women. From these results, further study should be considered gender differences in health status of elders and carried in larger sample than this study.

  • PDF

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

A Study on the Validity and Reliability of the Eight-Constitution Questionnaire (8체질(體質) 설문지(說問紙)의 타당도(妥當度), 신뢰도(信賴度)에 관한 연구(硏究))

  • Min, Jae-Young;Kim, Min-Yong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.2
    • /
    • pp.27-44
    • /
    • 2007
  • Background: Eight-Constitution Medicine (ECM) classifies the human body into eight constitutions. Diagnosis of discrimination of the eight constitutions depends on a unique pulse diagnosis. However, pulse diagnosis is subjective and requires vigorous training. Objectives: This study aims to analyze the validity and reliability of the Eight-Constitution Questionnaire as a diagnostic method. Methods: Participants of this study were outpatients in six ECM clinics located in Seoul. The resources were collected from 409 patients who were classified into one of the eightconstitutions according to their pulse types and their responses to constitution-acupuncture therapy. SPSS 13.0 for Windows was used for statistical analysis: factor analysis, reliability analysis, independent sample t-test, and multinomial logistic regression were used to verify the results. Results and Conclusions: 1. The proportion of participants' constitutions is in the order of Pancreotonia (23.7%), Colonotonia (19.8%), Pulmotonia (18.1%), Hepatonia (16.9%), Vesicotonia (8.1%), Cholecystotonia (7.3%), Renotonia (5.3%) and Gastrotonia (0.7%). 2. Sevencomponents and 74 items were selected through factor factor and relaibility analysis performed on about 251 items. 3. The firstcomponent's mean is significantly higher in Pancreotonia than that in other constitutions (p<0.05). The second is in Pulmotonia and Colonotonia, whereas the third is in Hepatonia and Cholecystotonia. Fifth is in Vesicotonia, the sixth is in Colonotonia, and the fourth and seventh are not significant in specific constitutions. 4. The percentage that Pancreotonia is correctly predicted is 96.9%, Pulmotonia is 91.9%, Colonotonia is 91.4%, Hepatonia is 88.4%, Vesicotonia is 81.8%, Gastrotonia is 66.7%, Renotonia is 66.7%, Choleeystotonia is 30.0%, and the total percentage is 85.3%.

  • PDF

Development of LED Module for Tooth Care with Effect of Promoting Scar Treatment and Analysis of Optical Properties (흉터 치료 촉진 효과를 갖는 치아 케어용 LED 모듈 개발과 광학적특성 분석)

  • Yoo, Kyun-Man;Son, Jeong-Hueon;Jo, Hyun-Min;Kang, So-Hi;Kang, Seong-Soo;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.701-708
    • /
    • 2020
  • In this paper, we analyzed the optical properties of the LED module for dental care, which has the effect of promoting cell regeneration and scar treatment. The LED module is a U-shaped module suitable for the shape of teeth. It is manufactured with an LED module (632 nm) and an LED module (632 nm + 870 nm), analyzes the results of optical properties, sets the irradiation distance, irradiation time, and is effective in healing skin wounds. Evaluation was conducted. It was tested in 6 test groups according to the light irradiation conditions, and light was irradiated to the scar site every other day for 7 days, 1 day and 3 days. As a result, it was confirmed that the effect of scar treatment was the highest when the combined wavelength of 632 nm + 870 nm was irradiated in pulse mode than when the single wavelength was irradiated and the composite wavelength was continuously irradiated. In group C group irradiated with PW Mode: pulse mode (period 36 ms, pulse width 35 ms) using a composite wavelength with LED module (632 nm + 870 nm) than group A without light irradiation, the length of scar reduction was 19 %, the area of the scar was further reduced by 10%, and it was confirmed that it is effective in treating scars in the wound area.

An extension of new laser pulse atom-probe construction and time-of-flight mass spectrum of $H_2$ and He gas (A new laser pulse atom-probe 제작 및 $H_2$ 가스와 He 가스의 time-of-flight mass spectrum)

  • 송순달;홍남관
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.465-472
    • /
    • 1997
  • An extension of new test methods for surfaces with an apparatus based on photon-induced desorption and ionisation in the electric field, is constructed and tested, It also investigates how to show the efficiency of the arrangement adsorbates $H_2$ and He on W(110). The field emitter temperature was 80 K. The wavelength of light used was 193 nm with field strengths between 10 and 50 V/nm. Many ion fragments($CO^+, He^+, H_2^^+, H_2O^+, W^{3+}\; and\; W^{2+}$) were produced by an electronic stimulation of the adsorbate with the help of a photon energy of 6.4 eV at He and $H_2$/W(110). A transient recorder enables the registration of the entire mass spectrum.

  • PDF

Homogeneity of lightweight aggregate concrete assessed using ultrasonic-echo sensing

  • Wang, H.Y.;Li, L.S.;Chen, S.H.;Weng, C.F.
    • Computers and Concrete
    • /
    • v.6 no.3
    • /
    • pp.225-234
    • /
    • 2009
  • Dredged silt from reservoirs in southern Taiwan was sintered to make lightweight aggregates (LWA), which were then used to produce lightweight aggregate concrete (LWAC).This study aimed to assess the compressive strength and homogeneity of LWAC using ultrasonic-echo sensing. Concrete specimens were prepared using aggregates of four different particle density, namely 800, 1100, 1300 and 2650 kg/$m^3$. The LWAC specimens were cylindrical and a square wall with core specimens drilled. Besides compressive strength test, ultrasonic-echo sensing was employed to examine the ultrasonic pulse velocity and homogeneity of the wall specimens and to explore the relationship between compressive strength and ultrasonic pulse velocity. Results show that LWA, due to its lower relative density, causes bloating, thus resulting in uneven distribution of aggregates and poor homogeneity. LWAC mixtures using LWA of particle density 1300 kg/$m^3$ show the most even distribution of aggregates and hence best homogeneity as well as highest compressive strength of 63.5 MPa. In addition, measurements obtained using ultrasonic-echo sensing and traditional ultrasonic method show little difference, supporting that ultrasonic-echo sensing can indeed perform non-destructive, fast and accurate assessment of LWAC homogeneity.

The Effects of the Inhalation Method Using Essential Oils on Blood Pressure and Stress Responses of Clients with Essential Hypertension (향기흡입법이 본태성고혈압 환자의 혈압 및 스트레스반응에 미치는 효과)

  • Hwang, Jin-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.7
    • /
    • pp.1123-1134
    • /
    • 2006
  • Purpose: The purpose of this study was to identify the effects of aromatherapy on blood pressure and stress responses of clients with essential hypertension. Method: There were fifty-two subjects divided into an essential oil group, placebo group, and control group by random assignment. The application of aromatherapy was the inhalation method of blending oils with lavender, ylangylang, and bergamot once daily for 4 weeks. To evaluate the effects of aromatherapy, blood pressure and pulse were measured two times a week and serum cortisol levels, catecholamine levels, subjective stress, and state anxiety were measured before and after treatment in the three groups. Data was analyzed by repeated measures of ANOVA, one-way ANOVA, and $X^2-test$ using the SPSS 10.0 program. Results: The blood pressure, pulse, subjective stress, state anxiety, and serum cortisol levels among the three groups were significantly statistically different. The differences of catecholamine among the three groups were not significant statistically Conclusion: The results suggest that the inhalation method using essential oils can be considered an effective nursing intervention that reduces psychological stress responses and serum cortisol levels, as well as the blood pressure of clients with essential hypertension.

Estimation of Thickness of Concrete Structures using the Impact Echo Method and Ultrasonic Pulse Velocity Method

  • Hong, Seonguk;Lee, Yongtaeg;Kim, Seunghun;Lee, Changsik
    • Architectural research
    • /
    • v.18 no.4
    • /
    • pp.179-184
    • /
    • 2016
  • The structure must be periodically checked and measures must be taken to prevent deterioration in building construction. From this point of view, a nondestructive test is essential to estimate whether the construction of buildings is proper, and whether the dimension of depositing concrete is consistent and without damage. This study estimated the thickness of the concrete component of construction framework using the ultrasonic velocity method and the impact echo method, in order to investigate reliability of the estimation of the thickness of normal strength concrete and high strength concrete, leading to the following conclusions. In the estimation of the thickness of the concrete structures, specimens of normal strength of 24MPa and specimens of high strength of 40MPa demonstrated an average error rate of 5.1% and 2.2%, respectively. The impact-echo method, one of the non-destructive tests, is verified as an efficient diagnostic technique. With this information, we will determine specific standards for the maintenance of structures, and the re-creation of lost building blueprints.