• Title/Summary/Keyword: Pulse system

검색결과 3,050건 처리시간 0.03초

Noncoherent UWB 시스템을 위한 펄스 반복 전송 기반의 선택적 검출 기법 (A Selective Detection Scheme based on Pulse Repetition for Noncoherent UWB systems)

  • 김재운;박영진;이순우;이재진;서철헌;신요안
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.185-186
    • /
    • 2007
  • In this paper, We propose the selective detection scheme based on pulse repetition considering Bit Error Rate (BER) performance and complexity of noncoherent Ultra Wide Band (UWB) systems. To consider system complexity, the proposed scheme transmits the UWB signals by pulse repetition at the transmitter, like the conventional Pulse Repetition Coding (PRC). However, to effectively improve BER performance of the system the proposed scheme performs selective detection by estimating the Signal-to-Noise Ratio (SNR) of the received pulse-repeated signal at the receiver. Hence, the proposed scheme effectively improves BER performance of the noncoherent UWB systems without increase of the system complexity, as compared to the conventional PRC algorithm.

  • PDF

맥진 데이터의 온톨로지 표현과 진단 서비스 추론 시스템 (Ontology Representation of Pulse-Diagnosis Data and an Inference System for the Diagnosis Service)

  • 양동일;박순희;임화정;양해술;최형진
    • 정보처리학회논문지B
    • /
    • 제15B권3호
    • /
    • pp.237-244
    • /
    • 2008
  • 본 논문에서는 온톨로지로 구축된 맥 정보를 이용하여 유비쿼터스 컴퓨팅 환경에서 의료 정보 시스템의 상황 인식 서비스를 할 수 있도록 하는 기반 구조를 제안한다. 피검사자의 웨어러블 신호, 온도, 습도 그리고 시간 등을 요소로 사용하는 진맥 인식을 통하여 얻어진 맥진 데이터를 온톨로지로 표현하고 이를 바탕으로 진료 서비스 시나리오를 작성하는 진단 서비스 추론 시스템을 설계 및 구현하였다.

바이스태틱 레이더의 시스템 불안정 요소들에 대한 분석 (Analysis of System Instability Factors in a Bistatic Radar)

  • 양진모;이민준;윤재룡;김환우
    • 한국군사과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.114-122
    • /
    • 2011
  • In this paper, we have identified the system instability factors in a bistatic radar system using pulse chasing and considered their effects on the bistatic receiver's MTI(Moving Target Indication) improvement performance. The pulse chasing is a method to efficiently scan a restricted search area within the limited transmitter power and time in a bistatic radar and to track a series of transmitted pulses using the receiver beam which has ideally matched to the pulse propagation rate. In this paper, we have discussed the interrelationship between the pulse chasing and time and frequency/phase synchronization and described the effects of the identified system instability factors on two kinds of MTI filter configuration, single delay-line and double delay-line, in the bistatic radar. And also, we have confirmed that the overall system improvement is restricted by a lower improvement factor among identified them, and discussed the allowable tolerance of the time and frequency/phase synchronization in the bistatic system.

Computer-Aided Crafting of Pulse Shapes for Broadband Heteronuclear Decoupling in the presence of Homonuclear Coupling

  • Lee, Chang-Jae
    • 한국자기공명학회논문지
    • /
    • 제3권1호
    • /
    • pp.36-43
    • /
    • 1999
  • We present a pulse shape tailored for broadband decoupling for a system of spin-1/2's with scalar couplings as well. In crafting the pulse shape Coherent Averaging Theory and Fourier expansion method are used. The Fourier expansion coefficients are optimized numerically by applying the Simulated Annealing Method. The decoupling performance of the shaped pulse thus designed is then compared with the well-known composite pulse sequence, DIPSI-2. It is shown that the shaped pulse performs well even at the conditions where the DIPSI sequence begins to fail.

  • PDF

Parameter Estimation of The Distributed System via Improved Block Pulse Coefficients Estimation

  • Kim, Tai-hoon;Shim, Jae-sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.61.6-61
    • /
    • 2002
  • In these days, Block Pulse functions are used in a variety of fields such as the analysis and controller design of the systems. In applying the Block Pulse function technique to control and systems science, the integral operation of the Block Pulse series plays important roles. This is because differential equations are always involved in the representations of continuous-time models of dynamic systems, and differential operations are always approximated by the corresponding Block Pulse series through integration operational matrices. In order to apply the Block Pulse function technique to the problems of continuous-time dynamic systems more efficiently, it is necessary to find th...

  • PDF

4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I) (Implementation of 4 Channel Photo-Plethysmogram System(I))

  • 김형태;한순천;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF

다중 사용자 환경에서의 DS-PAM과 TH-PPM UWB 시스템의 분석과 응용 (Analysis and Applications of Multi-user DS-PAM and TH-PPM UWB System)

  • 성태경;김동식;김철성;조형래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.603-610
    • /
    • 2008
  • In this paper, analytical methods for calculating the average probability of bit error of direct sequence pulse amplitude modulation ultra wideband (DS-PAM UWB) system and time hopping pulse position modulation ultra wideband (TH-PPM UWB) system are given. For the multi-user DS-PAM UWB system, the bipolar pulse amplitude modulation is used in order to achieve better performance. As we know, more attention is paid to the TH-PPM UWB systems recently. In this paper. we first introduce the accurate BER calculation methods of the multi-user DS-PAM UWB and TH-PPM UWB systems and then give the performance analysis over the ideal AWGN channel and a correlation receiver. Furthermore, we also introduce their applications in image transmission and data transmission and give the simulation results. The analytical method yields simple and exact formulas relating the performance to the system parameters.

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작 (Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구 (A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis)

  • 이준영;이정환;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

비정격(脾正格) 자침이 정상 성인 맥파(脈波) 변화에 미치는 영향 (The Effects of Sa-Am Spleen-tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 윤광식;이현
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.1-14
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the effects of Sa-Am spleen-tonifying acupuncture on radial pulse in healthy human subjects. Methods : Forty healthy human subjects participated in this study, divided into acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group. The subjects in the control group didn't received acupuncture but took a rest and then the radial pulse was measured at the same time points as the acupuncture group. The parameters were analyzed by gender, measuring location, and measuring time point. However the time related parameters exceptionally were analyzed without distinction of measuring location. Results : 1. T, variance of period, T2/T, T4/T, (T-T4)/T, T4/(T-T4), and W significantly changed after acupuncture. 2. Pressure, amplitude of H1, amplitude of H2, Amplitude of H4 and pulse energy significantly changed after acupuncture. 3. Pulse area, systolic pulse area and diastolic pulse area significantly changed after acupuncture. 4. Elasticity, AIx and AIx/HR significantly changed after acupuncture. Conclusions : The effect of Sa-Am spleen-tonifying acupuncture in healthy human may be observed on time, amplitude, pulse area and augmentation index. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.