• Title/Summary/Keyword: Pulse system

Search Result 3,045, Processing Time 0.032 seconds

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Clinical Study of Vascular Injuries (혈관 손상의 임상적 고찰)

  • Chung, Sung-Woon;Kim, Young-Kyu
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.480-484
    • /
    • 2007
  • Background: Major vascular injuries can jeopardize a patient's life or imperil limb survival. We performed this study to establish an optimal management plan for vascular injuries. Material and Method: We retrospectively reviewed 26 cases of vascular injury that were treated at Pusan National University Hospital from May, 1999 to September, 2004. The age and sex distribution, the locations and causes of vascular injury, the diagnostic tools, the degree of injuries, clinical manifestations, the treatment modality and complications were reviewed. Result: The mean age was 39.5 years (range: $12{\sim}86$) and the male to female ratio was 22 : 4. The injuries were in 6 descending thoracic aortas, 4 femoral arteries, 4 popliteal veins and so on. The causes of injury were iatrogenic in 8 cases, traffic accident in 7, stab injury in 6 and industrial accident in 5. The most commonly used diagnostic tools were CT and angiography. The degrees of arterial injury were pseudoaneurysm in 10 cases, partial severance in 5, complete severance in 3 and thrombosis in 3. The degrees of venous injury were partial severance in 6 cases, complete severance in 2 and arteriovenous fistula in 2. The clinical manifestations were absence of pulse in 8 cases, coldness in 7, chest pain in 6, swelling in 5, bleeding in 5 and so on. The most frequently used type of revascularization was graft interposition in 11 cases. Two arteriovenous fistulae were repaired by endovascular procedure. There was one case of mortality due to multi-organ failure after hemorrhagic shock, There were three major amputations, and two of them were due to delayed diagnosis and treatment. Conclusion: A system for the early diagnosis and treatment is essential for improving limb salvage and patient mortality. As a consequence of the widespread application of endovascular procedures, the incidence of iatrogenic injuries has recently increased. Educating physicians is important for the prevention of iatrogenic injury. Easy communication and cooperation for earlier involvement of a vascular surgeon is also an important factor.

Study on Effect of Varience of Physiological Responses in Color Foot Reflexology Using Color Light (컬러광을 활용한 발반사요법이 인체 생리적 반응 변화에 미치는 영향에 관한 연구)

  • Jin, Hye-Ryeon;Yu, Mi;Park, Kyung-Jun;Kim, Nam-Gyun;Chung, Sung-Whan;Kim, Dong-Wook
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.187-196
    • /
    • 2010
  • Recently, people have been suffering from stress-related fatigue and psychological disorders. Most people depend on medicine for pain relief; many treat pain also through alternative medicine or replacement therapy. However, drug therapy has many side effects, including increased stress after the therapy. In comparison, alternative therapies such as massage and foot reflexology are less damaging to the body, and such therapies can be provided without physical or psychological discomfort. In this regard, the author had previously co-developed color foot reflexology, which combines the merits of color therapy and foot reflexology; color foot reflexology has been shown to have beneficial effects without undue pain. This study investigates the effects of color foot reflexology on the physiological response of the body by comparing the body’s response to the signal with that to the placebo. Healthy adult subjects were selected for the experiment, which was conducted under optimal experimental conditions and design. The results indicated that when stimulated, parasympathetic nerves increased in HRV and that blood pressure, pulse, body heat, peripheral blood flow were dramatically activated. However, the results for the placebo indicated minimal changes or irregular outcomes. The results provide strong evidence for the beneficial effects of the color foot reflexology instrument on the autonomic nervous system and on the physiological response of the body. Future research is warranted to verify the results of the current study by examining patients suffering from diseases and disorders arising from irregular physiological functions in the context of the foot.

  • PDF

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF

Growth Characteristics of Lettuce under Different Frequency of Pulse Lighting and RGB Ratio of LEDs (LED의 간헐조명과 RGB 비율에 따른 상추의 품종별 생육 특성)

  • Kim, Sungjin;Bok, Gwonjeong;Lee, Gongin;Park, Jongseok
    • Journal of Bio-Environment Control
    • /
    • v.26 no.2
    • /
    • pp.123-132
    • /
    • 2017
  • This study was aimed to investigate the effect of 1)irradiation with several different ratios using red, green, and blue LEDs and 2)various pulsed light irradiation with 50% duty ratio using red and blue LEDs on the growth and morphogenesis of three lettuce cultivars (Lactuca sativar L. cv. 'Jukchukmeon', 'Lolo Rosa', and 'Grand Rapid') in hydroponics culture system for 4 weeks after transplanting. Seeds were sown in rock-wool plug trays and they were placed in a culture room which was controlled at $23{\pm}1^{\circ}C/18{\pm}1^{\circ}C$ temperature and 50-60/70-85% for day and night, respectively, during cultivation period. Irradiated RGB ratios with LEDs were 6:3:1, 5:2.5:2.5, 3:3:4, 2:2:6, and 1:1:8 with $110{\pm}3{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD on the surface of cultivation bed. The frequencies of pulsed lighting was 50, 100, 500, 1,000, 5,000, 10,000, 25,000Hz (20, 10, 0.1, 0.04 ms) with red and blue LEDs and 50% duty ratio. At the RGB ratio of 6:3:1, the average fresh weight of 'Jukchukmeon' was significantly higher than that of other RGB treatments, but no significant difference compared to the fluorescent treatment. The average fresh weight at 1:1:8 RGB ratio in 'Lolo Rosa' was significantly lower than that of other RGB treatments. Leaf number and fresh weight of 'Grand Rapid' were significantly lower in the control and 1:1:8 RGB treatments, compared to the other RGB treatments. As the ratio of blue light increased, leaf length decreased and leaf shape became round in three lettuces. Although there is little change in growth, it could not be found any tendency to affect the growth and morphogenesis of three lettuces caused by increasing or decreasing frequency of pulsed lighting with 50% duty ratio at the $72{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Rainfall and Hydrological Comparative Analysis of Water Quality Variability in Euiam Reservoir, the North-Han River, Korea (북한강 의암호의 수질 변동성에 대한 강우·수문학적 비교분석)

  • Hwang, Soon-Jin;Sim, Yeon Bo;Choi, Bong-Geun;Kim, Keonhee;Park, Chaehong;Seo, Wanbum;Park, Myung-Hwan;Lee, Su-Woong;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.1
    • /
    • pp.29-45
    • /
    • 2017
  • This study explored spatiotemporal variability of water quality in correspondence with hydro-meteorological factors in the four stations of Euiam Reservoir located in the upstream region of the North-Han River from May 2012 to December 2015. Seasonal effect was apparent in the variation of water temperature, DO, electric conductivity and TSS during the study period. Stratification in the water column was observed in the near dam site every year and vanished between August and October. Increase of nitrogen nutrients was observed when inflowing discharge was low, while phosphorus increase was distinct both during the early season with increase of inflowing discharge and the period of severe draught persistent. Duration persisting high concentration of Chl-a (>$25mg\;m^{-3}$: the eutrophic status criterion, OECD, 1982) was 1~2 months of the whole year in 2014~2015, while it was almost 4 months in 2013. Water quality of Euiam Reservoir appeared to be affected basically by geomorphology and source of pollutants, such as longitudinally linked instream islands and Aggregate Island, inflowing urban stream, and wastewater treatment plant discharge. While inflowing discharge from the dams upstream and outflow pattern causing water level change seem to largely govern the variability of water quality in this particular system. In the process of spatiotemporal water quality change, factors related to climate (e.g. flood, typhoon, abruptly high rainfall, scorching heat of summer), hydrology (amount of flow and water level) might be attributed to water pulse, dilution, backflow, uptake, and sedimentation. This study showed that change of water quality in Euiam Reservoir was very dynamic and suggested that its effect could be delivered to downstream (Cheongpyeong and Paldang Reservoirs) through year-round discharge for hydropower generation.

Empirical Study of Key Factors in Satisfaction with Subway Services (지하철 이용만족도 결정요인에 관한 실증적 연구 -서울지역을 중심으로-)

  • Shim, Jong-Seop;Jeon, Ki-Heung
    • Korean Business Review
    • /
    • v.13
    • /
    • pp.49-66
    • /
    • 2000
  • Despite the fact that understanding customers satisfaction with transportation services is a subject of great importance, authors, so far, found no systematic researches referred to that issue. From this point, studying the satisfaction with subways services can be extremely useful. Empirical study of key factors in the satisfaction with subway services is the departure point, which holds as objectives, and we believe, will contribute to overall increasing in the number of subways services used and in the amount of public benefits derived from that usage. In order to achieve these goals: First, several items referred to some key factors in the satisfaction of subway usage were systemized. Second, a research of specific weights attached to those key factors by subway passengers was conducted. Knowledge of the satisfaction variables system can provide deep insights into ones perceptual experience when using a subway. The results were as follows: Various interrelated factors compose a passengers satisfaction with subway services. People do not just use subway passively; a number of key factors, like physical and personal services, exact timing, easiness to access etc. determine the passengers satisfaction with subway. In order to find out specific weights of these key factors multiple regression analysis was employed. Results showed that satisfaction with subway is determined by (in order of importance) easiness to access, quality of physical services, friendliness of working stuff and timing exactness. According to the findings, passengers do not use subway as a simple mean of transportation, rather they perceive it as a complex combination of environmental elements and overall satisfaction depends on these various factors. Therefore, to learn passengers satisfaction with subways services, passengers subway experience must be thoroughly studied and analyzed, and this is where papers value resides.

  • PDF

Effect of Fusion Condition on In Vitro Development of Caprine Cloned Oocytes with Nuclear Transfer (재래산양에 있어서 핵이식란의 융합조건이 융합 및 체외발달에 미치는 영향)

  • 박희성;김태숙;이윤희;정수영;이명열;홍승표;박준규;김충희;정장용
    • Reproductive and Developmental Biology
    • /
    • v.28 no.2
    • /
    • pp.127-132
    • /
    • 2004
  • This study was conducted to examine the effects of electric stimulation conditions on in vitro developmental ability of caprine embryos after somatic cell nuclear transfer. Recipient oocytes were surgically collected after superovulation by using CIDR and FSH, PMSG, hCG and estrous synchronization in Korean native goats. The caprine ear cells were cultured in vitro in serum-starvation condition (TCM-l99 + 0.5% FBS) for 3 to 5 days of cell confluence. The zona pellucida of in vivo and in vitro matured oocytes were partially drilled using laser system. Single somatic cell was individually transferred into the enucleated oocyte. The reconstructed oocytes were electrically fused with 0.3M mannitol. After the electofusion, embryos were activated by electric stimulation or Ionomycin + 6-DMAP. Nuclear transfer embryos were cultured in mSOF medium supplemented with 0.8% BSA 6∼7 days at 39 , 5% $CO_2$, 5% $O_2$, 90% $N_2$. The fusion rate of donor cells was 60.4% and 40.3 % in ear cell and fetal fibroblast, and cleavage rate were 40.6% and 48.2%, respectively. No significant difference was found in the fusion and cleavage rate in different donor cells. Nuclear transferred oocytes were fused by electric pulses of 1.30∼1.40, 2.30∼2.39 and 2.40∼2.46 ㎸/cm. There was no significant difference among different electric pulses in fusion rates (26.7, 34.8 and 43.8%). The cleavage rate was higher (p<0.05) in 1.30∼1.40 ㎸/cm (82.9%) than 2.30∼2.39 ㎸/cm (43.8%) and 2.40∼2.46 ㎸/cm. (51.8%). The fusion rates of recipient oocyte source were 1st (43.5% and 23.6%), 2nd (55.7% and 39.2%) and 3rd (66.1% and 52.8%) in in vivo and in vitro oocytes. However, fusion ratee were significantly higher (p<0.05) in in vivo than in vitro oocyte. The cleavage rate of fused oocytes from in vivo and in vitro sources were 52.6% and 54.4%, respectively. No significant difference was found in the cleavage rate according to the recipient oocyte source. These results suggest that factors such as field pulse of electric stimulation and oocyte source could affect in vitro developmental ability of nuclear transplanted caprine oocytes.

Analysis of Groundwater Flow Characterization in Fractured Aquifer System (파쇄대 응회암 대수층의 지하수 유동 특성화 기법)

  • Kim Yong-Je;Kim Tae-Hee;Kim Kue-Young;Hwang Se-Ho;Chae Byung-Gon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.33-44
    • /
    • 2005
  • On the basis of a stepwise and careful integration of various field and laboratory methods the analysis of groundwater flow characterization was performed with five boreholes (BH-1, -2, -3, -4, -5) on a pilot site of Natural Forest Park in Guemsan-gun, Chungcheongbook-do, Korea. The regional lineaments of NW-SE are primarily developed on the area, which results in the development of many fractures of NW-SE direction around boreholes made in the test site for the study. A series of surface geological survey, core logging, geophysical logging, tomography, tracer tests, and heat-pulse flowmeter logging were carried out to determine fracture characteristics and fracture connectivity between the boreholes. In the result of fracture connectivity analysis BH-1 the injection well has a poor connectivity with BH-2 and BH-3, whereas a good with BH-4 and BH-5. In order to analyse the hydraulic connectivity between BH-1 and BH-5, in particular, a conspicuous groundwater outflux in the depth of 12 m and influx in the depth of 65 m and 70 m, but partly in/outflux occurred in other depths in BH-5 were observed as pumping from BH-1. On the other hand, when pumping from BH-5 the strong outflux in the depths of 17 m and 70 m was occurred. The spatial connectivity between the boreholes was examined in the depth of 15 m, 67 m, and 71 m in BH-1 as well as in the depth of 15 m, 17 m, 22 m, 72 m, and 83 m in BH-5.