• Title/Summary/Keyword: Pulse system

Search Result 3,050, Processing Time 0.254 seconds

The Literature Study on Macula among the Symptoms of Warm Factor Disease (온병(溫病)의 증상(症狀) 중(中) 반진(斑疹)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Jang, Yunjeong;Ryu, Sangchae;Kim, Jeongsoon;Jeon, Hoseong;Yu, Donghee;Kim, Nanyeong;Chong, Myongsoo;Lee, Kinam
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.11 no.1
    • /
    • pp.80-116
    • /
    • 2009
  • It studies into viewpoints of 7 doctors of Wenbing studies on macula. The results concerning characteristics, remedy and prevention of macula are as follows; Macule does not protrude on the surface of skin and does not have any color change for external stimulus, but rash out on the surface and becomes white when pushed. It becomes macule when the blood leaks beneath skin as stomach-heat of yangming enters into blood system and damages it. On the other hand, when heat enters lung meridian, penetrates beneath the skin and congeals inside the vessel, it becomes rash. When you combine symptoms of body and pulse with numbers, color, shape and distribution status of macula, you can diagnose the depth of rash, seriousness, the possibility of treatment and prognosis of macula. The remedy for macule consists of cooling heat of yaming, removing heat from the blood and relieving feverish rash, and the one for rash consists of facilitating meridian with aroma, expelling pathogenic factors from muscles with drugs of pungent flavor and cool nature and clearing away heat from the blood systems. It relieves the inhibited functional activities of lung-Ki, and helps extermination of rash as well as clearing heat of the vessel. Also, it is the most important to preserve resin of stomach for every treatment. It is good to avoid expelling pathogenic factors with drugs of pungent flavor and warm nature, raising drugs and invigorating drugs during treating macula. Moreover, the patients should not over dose cold-natured drugs and purgative therapy. There are common clinical symptoms of macula in advance, so right recognition of symptoms can contribute to prevention of macula.

Effects of Post-Tensioning Tendons and Vehicle Speeds on Dynamic Response of Concrete-Filled Steel Tubular Tied Arch Girder (긴장재 및 차량속도 변화에 따른 콘크리트 충전 타이드 아치형 거더의 동적거동)

  • Roh, Hwasung;Hong, Sanghyun;Park, Kyunghoon;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.163-172
    • /
    • 2011
  • The CFTA girder developed is a concrete filled steel tubular system with arched shape and external post-tensioning (PT) tendons which control the initial camber and the bending stress of the girder. In the present study the effects of the PT tendons on the dynamic behavior of the girder subjected to a moving vehicle load are numerically investigated. Various levels for the tendon quantity and the tendon forces are considered, using the existing FE model of the girder. The vehicle considered is a DB-24 truck and is modeled with two tracks-three axles. Equivalent-load pulse time histories are applied to each node to simulate the moving vehicle, depending on the time of arrival and the discretization. The vehicle speeds are varied from 40 km/hr to 100 km/hr with increment of 20 km/hr. The analysis results show that the tendon forces do not produce any influences on the dynamic responses of the girder. However the dymamic deflection of the girder increases when a smaller amount of tendons is used. The Dynamic Amplification Factors (DAF) are evaluated based on the static and dynamic responses. Much lower values of the DAF are obtained, even no tendons applied, than those provided by the design criteria of the AASHTO LRFD and the Korea Highway Standard Specification.

Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T (복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2016
  • This study conducted an analysis to compare the differences in the properties of the magnetic field and the generation of artifacts because of the difference in the magnetic field between 1.5 T equipment and 3.0 T equipment, centering around four types of pulse sequences, mainly applied to the abdominal Magnetic Resonance Imaging (MRI). With data on 500 persons transmitted to the PACS, this study analyzed the SNR value, quantitatively and carried out a qualitative evaluation, dividing MSA, CSA, and DA into three steps. As a result of the quantitative evaluation, the SNR value was significantly higher in the 1.5 T equipment; however, there was a factor deteriorating the image quality, too, as artifacts were generated in the images. The 1.5 T equipment generated fewer artifacts than the 3.0 T equipment did, so it could compensate the image quality for 3.0 T. In conclusion, based on these findings, this study could understand the differences in the properties of the magnetic field and the generation of artifacts occurring because of the difference in the magnetic field and could provide a measure for them. This study would be guidelines for MRI users who directly examine the patients in abdominal MRI using the two types of equipment in the clinical setting in the future.

The Mechanism for Analgesic Effects of Electroacupuncture on Surgical Ankle Sprain Model Classified as Grade 3 in Rats (수술적 방법으로 유도된 3단계 발목염좌에 대한 전침의 진통기전 연구)

  • Yang, Seung-Bum;Choi, Suck-Jun;Lee, Sung-Ho;Kim, Min-Su;Sohn, In-Chul;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Objectives : Electroacupuncture(EA) has been used effectively in producing analgesia on ankle sprain pain of humans and animals. Currently to examine the underlying mechanisms of the EA-induced analgesia, the effects of EA on weight-bearing forces(WBR) were examined at ankle sprain classified as grade 3 in rats. Methods : The severe ankle sprain classified as grade 3 was induced surgically by ankle ligament injury in the Sprague-Dawley rats. WBR of the affected foot were examined to evaluate effects and mechanism of EA(2 Hz, 1 ms pulse width, 2 mA intensity, for 15 min) which was applied to either SI6, GB34, or GB39 acupoints. The rats were pretreated with naltrexone(10 mg/kg, i.p.) as an opioid receptor antagonist or phentolamine(5 mg/kg, i.p) as an ${\alpha}$-adrenoceptor antagonist at 30 min before EA. Results : The daily repeat EA at either SI6, GB34, or GB39 showed significant analgesic effects on the severe ankle sprain. Particularly, daily EA at GB34 showed more potent analgesic effect than the others. In addition, the naltrexone pretreatment completely blocked the analgesic effect of EA at GB34, indicating the involvement of the endogenous opioid system in mediating the effect of EA at GB34. However, the phentolamine pretreament blocked analgesic effects of EA at either SI6 or GB39, indicating the involvement of ${\alpha}$-adrenoceptors in mediating the effect of EA at either SI6 or GB39. Conclusions : These data suggest that EA-induced analgesia on ankle sprain pain is mediated through either endogenous opioids or ${\alpha}$-adrenoceptors dependant on acupoint specific pattern.

The Effect of Ultrasound Irradiation on the Neural Cell Adhesion Molecules(NCAM) Expression in Rat Spinal Cord after the Sciatic Nerve Crush Injury (초음파가 흰쥐의 좌골신경 압좌손상 후 척수내 Neural Cell Adhesion Molecules의 발현에 미치는 영향)

  • Kim, Hyun-Ae;Han, Jong-Man
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.41-55
    • /
    • 2007
  • Purpose: This study aimed to compare the effect on nerve regeneration of ultrasound irradiation in rats with peripheral nerve injury. Methods: To investigate alterations of the NCAM immunoreactivity in non-crushed part and crushed part of the spinal cord, the unilateral sciatic nerve of the rats were crushed. The expression of NCAM was used as the marked of peripheral nerve regeneration, and also plays an important role in developing nerve system. Experimental animals were sacrificed by perfusion fixation at post-injury 1, 3, 7, 14 days after ultrasound irradiation. The pulsed US was applied at a frequency of 1MHz and a spatial average-temporal average Intensity of 0.5W/of (20% pulse ratio) for 1 mins. The Luxol fast blue-cresyl violet stain were also done to observe the morphological changes. Results: Alteration of NCAM immunoreactivity in the crushed part and the non-crushed part of lower lumbar spinal cord were observed. NCAM-immunoreactivity cells were some increased in the dorsal horn lamina I, III and cell ventral horn at 1 day after unilateral sciatic nerve injury. However, there was not significant difference in the relationship between crushed part and non-crushed part. NCAM-inmmunoreactivity was remarkably increased at 3 days after unilateral sciatic nerve injuryin the gray matter and white matter. NCAM-immunoreactivity was increased in the ventral horn and post horn of experimental crushed part. Also, NCAM-immunoreactivity in large motor neurons in ventral horns lamina VIII, IX were increased at 7 days after unilateral sciatic nerve injury. At 14 days after sciatic nerve crushed injury, there was no significant difference. All group were decreased for 14 days. In the time course of NCAM expression, all groups showed a significant difference at 3day groups(p<0.05). Whereas, CC group was noted a significant difference between 3day and 7 day group respectively. In NCAM expression, there were significantly increased in all group. In the relationship between CNC group and ENC group, significant difference was detected among 3, 7, 14 day group(p<0.05). The difference between CC group and ENC group were noted in all groups(p<0.05). Conclusion: It is consequently suggested that the effects of the ultrasound irradiation may increase the NCAM immunoreactive neurons and glial cell in the spinal cord after unilateral sciatic nerve crushed injury. Therefore, the increased NCAM immunoreactivity in the spinal cord may reflect the neuronal damage and healing process induced by a ultrasound irradiation after peripheral nerve injury in rat.

  • PDF

Development of Unfolding Radial Velocity Algorithm for Dual PRF Mode of Yong-In Testbed(YIT) Radar (용인테스트베드레이다를 이용한 Dual PRF 모드의 시선속도 접힘 풀기 알고리즘 개발)

  • Kim, Hye-Ri;Suk, Mi-Kyung;Nam, Kyung-Yeub;Ko, Jeong-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.521-530
    • /
    • 2016
  • Weather radar is observation equipment that transmits electromagnetic waves and receives backscattered signals from the targets. The weather radar systems of the Korea Meteorological Administration have a doppler mode that can extract the target's radial velocity. However, the radial velocity over the maximum unambiguous velocity(${\nu}_m$) for which is in a trade-off relationship with the maximum unambiguous range is folded. Therefore, a dual PRF mode of which transmits and receives signals using two different PRFs(high and low) must be used to extend the vm while maintaining the maximum unambiguous range. Using a dual PRF mode, vm can be extended to the amount of lowest common denominator of two observed vm from high and low PRF. For this extension, we have developed a velocity unfolding algorithm of which uses several criteria for classification considering observed velocity differences between high and low PRF and their error boundary. Then, correction factors are calculated for each class and are applied to unfold radial velocity. The developed algorithm was applied to the Yong-In Testbed(YIT) radar and the generated better performance of radial velocity extraction than those of the previous system.

Design for Dispersion Map in Submarine Optical Network (장거리 해저 광전송망 분산보상 설계 및 구현)

  • Yoo, Jae-Duck;Park, Hong-Tae;Shin, Hyun-Sik;Kim, Chun-Suk;Shin, Yun-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • Currently, Most of the Backhual and Submarine's networks are being installed using DWDM and EDFA to deal with dramatically increasing internet traffic. In a conventional type optical system, the so-called 3R repeater, fiber non- linearity was not significant factor but it is one of the most important consideration when designing new DWDM network based on the EDFAs. To minimize the signal pulse distortion in long-haul optical network, Zero-dispersion fiber is indispensable but causes the fiber non-linearity. Therefore this conflicting problems should be managed to transmit a high-speed capacity traffic. In this paper, key technologies in DWDM submarine optic network were found out for a high capacity traffic and introduced the dispersion management way for solving the conflicting problems between Zero-dispersion and non-linearity. Lastly designed a dispersion map in section between Korea and Hong-kong.

  • PDF

Combined MRI and Relaxogram: A New Method of Fat Study (MRI와 Relaxogram을 이용한 지질 연구의 새로운 기법에 관한 연구)

  • Yongmin Chang;Yoo, Done-Sik;Kim, Tae-Hun;Kim, Yong-Joo;Kang, Duk-Sik;Robert B. Clarkson
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.23-32
    • /
    • 1999
  • Combined MRI and Relaxogram approach was introduced as a very useful tool for fat study. The phantoms simulating homogeneous mixture of fat and non-fat environments were measured with spin echo pulse sequence on a 0.15 T whole body imager. From 45 scans, the Tl values were obtained by fitting the data to continuous distribution (CONTIN) of relaxation time. This relaxogram gives broad distributions of relaxation time, which are characterized by a number of peaks with characteristic T1 values. Two distinct peaks in relaxogram were observed and identified as signals from com oil and gelatin gel. This model system can be served as simulating the distribution of fat in muscle. Also the relative ratio of two components, which is proportional to the area under the peak, is estimated and compared to nominal values. Based on the good agreement between two predictions, the values from our proposed method agreed with nominal values within $\pm$7 % error. The effects of different concentration of contrast agent and different region of interest are presented. To optimize total scan times, the minimum required data points and so further reduction in total scan times are discussed.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm)difference of skin excessive expense $CO_2$ Laser (피부과용$CO_2$ 레이저의 공극(1.0mm및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성 연구)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Turbo FLASH NRI Using Optimized Flip Angle Pattern: Application to Inversion-Recovery T1-Weighted Imaging (최적화된 Flip Angle Pattern을 사용한 Turbo FLASH MRI: Inversion-Recovery T1-Weighted Imaging에의 응용)

  • Oh, C.H.;Choi, H.J.;Yang, Y.J.;Lee, D.R.;Ryu, Y.C.;Hyun, J.H.;Kim, S.R.;Yi, Y.;Jung, K.J.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.55-56
    • /
    • 1998
  • The 3-D Fast Gradient Echo (Turbo FLASH, Turbo Fast Low Angle Shot) sequence is optimized to achieve a good T1 contrast using variable excitation flip angles. In Turbo FLASH sequence, depending on the contrast preparation scheme, various types of image contrast can be established. While proton density contrast is obtained when using a short repetition time with a short echo time and small flip angles, T1 or T2 weighting can be obtained with proper contrast preparation sequences applied before the above proton density Turbo FLASH sequence. To maximize the contrast to noise ratio while retaining a sharp impulse response (smooth frequency domain response), the excitation flip-angle pattern is optimized through simulation and experiments. The TI (the delay after the preparation sequence which is a 180 degree inversion RF pulse in the IR T1 weighted imaging case), TD (the delay time between the Turbo FLASH sequence and the next preparation), and TR are also optimized fur the best image quality. The proposed 3-D Turbo FLASH provides $1mm\times1mm\times1.5mm$ high resolution images within a reasonable 5-8 minutes of imaging time. The proposed imaging sequence has been implemented in a Medison's Magnum 1.0T system and verified through simulations as well as human volunteer imaging. The experimental results show the utility of the proposed method.

  • PDF