• Title/Summary/Keyword: Pulse system

Search Result 3,044, Processing Time 0.029 seconds

Analysis of Linear Time-invariant System by Using a New Block Pulse Operational Matrices (새로운 일반형 블럭 펄스 적분 연산 행렬을 이용한 선형 시불변 시스템 해석)

  • Lee, Hae-Ki;Kim, Tai-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.175-182
    • /
    • 2004
  • This paper presents a new method for finding the Block Pulse series coefficients, deriving the Block Pulse integration operational matrices and generalizing the integration operational matrices which are necessary for the control fields using the Block Pulse functions. In order to apply the Block Pulse function technique to the problems of state estimation or parameter identification more efficiently, it is necessary to find the more exact value of the Block Pulse series coefficients and integral operational matrices. This paper presents the method for improving the accuracy of the Block Pulse series coefficients and derives generalized integration operational matrix and applied the matrix to the analysis of linear time-invariant system.

Mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

The Fundamental Study on Pulse Jet Cleaning of Rectangular Bag-Filter System (사각형 여과 집진기 충격기류 탈진시스템의 기초 연구)

  • Piao, Cheng Xu;Kim, Tae Hyeung;Yang, Jun Ho;Li, Xiao Yu;Ha, Hyun Chul;Jung, Jae Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.149-160
    • /
    • 2008
  • Bag-filter system has been widely used in industrial field to remove the particulate matters from the exhaust gas. The cylindrical type of bag-filter has been generally used. But it has many shortcomings. The reattachment of separated particles on the surface of bags could result in high pressure drop of bag-filter system and subsequent decrease of air flow rate since the cylindrical type bag-filter system should have the upward flow pattern. In addition, the supply of very high pressure pulse air jet to remove particulate matters on the surface of filter could result in a frequent rupture of bags. To overcome these shortcomings of the cylindrical type, the rectangular type was developed in the developed countries and imported to Korea. But, there was not many design data available to understand the mechanisms. Thus, the fundamental experiments were conducted in this study to get some ideas about the pulse jet cleaning of rectangular type bag filter system. The experimental factors are as follows; pulse distance, pulse duration, pulse interval, pulse pressure and pulse nozzle type. Experiments followed the factorial design method. With the shorter pulse distance, the distribution of pressure drops was relatively not uniform while the particulate removal efficiency was higher. With the longer duration of pulsing and the more number of pulse nozzle, the removal efficiency was higher and the pressure drop distribution was more uniform.

Study of the relationship between manual pulse diagnosis and machinery measurement on QiguㆍInyoung comparison pulse diagnosis (기구인영비교맥법에 대한 수지맥진과 기기측정치의 상관성 연구)

  • Jun Yong Seck;Chae Wo Seck;Cho Myung Rae;So Cheal Ho;Choi Chan Hun;Jang Kyeang Sean
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.1
    • /
    • pp.201-208
    • /
    • 2002
  • The measurement parameter of QiguㆍInyoung pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Qigu and Inyoung. We have estimated the relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis by means of quantifying pulse peak and Inyoung/Qigu index. The results can be summarized as follows : When standardizing manual pulse diagnosis measurement was standardized, Inyoung index of machinery measurement was more significantly correlative with the index of manual pulse diagnosis than Qigu index of machinery measurement. The ratio of Inyoung/Qigu magnitude with machinery measurement was doser to manual pulse diagnosis than that of Qigu and Inyoung pulse magnitude measured separately. A linear proportion relationship was found between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis. It was necessary to adjust the output signal of pulse in order to estimate the exact relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis.

A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method (Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성)

  • Joung, Jong-Han;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

Pulse Diagnosis Algorithm and Digital Filter Design for Development of Digital Biomedical System (전자 맥진기 시스템 개발을 위한 맥파분석 알고리즘과 디지털 필터 설계)

  • Kim, Sang-Ho;Lim, Duk-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4473-4482
    • /
    • 2010
  • The examination of pulse, which is a typical palpation technique in the oriental medicine, has been used conventional analog system for discrimination of 28 pulses. However, the clipping phenomenon in the pulses, which used same feature extraction technique with ECG signals, has been occurred in analog system due to feature extraction method and over amplification from the input signals. It caused inaccurate to analyze the pulse signals. In this paper, we propose a digital filter design technique based on Prony's method for signal modeling and C-spline interpolation for feature extraction from pulse signal to compensate analog pulse detection system. In addition, we suggest a compensated electronic pulse detection system comprising new pulse analyzing algorithm and shape analysis technique for pulses, which were difficult to use in analog system. The feasibility for new proposed system has been confirmed comparing output signals between electronic pulse detection system having proposed filter design techniques with pulse analyzing algorithm and conventional analog system.

Development of multi-repetitive Pulse Compression System for excimer laser excitation (엑사이머 레이저 여기용 고반복 펄스압축 시스템 개발에 관한 연구)

  • 전상영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.36-38
    • /
    • 1989
  • We have developed Magnetic Pulse Compression System to realize repetitive excimer laser excitation. The principle of this system is to use the large change in permiability owing to the nolinear characteristics of ferro-magnetic material (Metglas2605s-2 metal ribon). Prior to the laser operation, the MPC system was tested with a dummy load (5$\Omega$) and laser head. Laser head has a discharge volume of 1.0 (w) x 2.0 (h) x 20.0(1) cm. This MPC system compressed a 6.2us (FWHM), 80 A pulse into a 0.4us(FWHM), 1.3kA pulse.

  • PDF

Remote Monitoring of Patients and Emergency Notification System for U-Healthcare

  • Lee, Jun;Jang, Hyun-Se;Yang, Tae-Kyu;Seo, Yong-Ho
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • This study proposes a remote monitoring of patients and emergency notification system with a camera and pulse wave sensor for U-Healthcare. The proposed system is a server client model based U-Healthcare system which consists of wireless clients that have micro-controller, embedded-board for patient status monitoring and a remote management server. The remote management server observes the change of pulse wave data individually in real-time sent from the clients that is to be remote-monitored based on the pulse wave data stored by users and divides them into caution section and emergency section. When the pulse wave data of a user enters an emergency situation, the administrator can make a decision based on the real-time image information and pulse rate variability. When the status of the monitored patient enters the emergency section, the proposed U-healthcare system notifies the administrator and relevant institutions. An experiment was conducted to demonstrate the pulse wave recognition of the proposed system.

Active Vibration Control of Smart Structure Using Pulse Width Modulation (펄스폭변조를 이용한 지능구조물의 능동진동제어)

  • Kwak, Moon K.;Kim, Ki-Young;Bang, Se-Yoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.1 s.94
    • /
    • pp.105-111
    • /
    • 2005
  • This paper is concerned with the active vibration control of smart structure using actuator signal made of pulse width modulation. The pulse width modulation has been used in motor control, where the amount of energy fed into the motor is controlled by the pulse width instead of applied voltage. The advantage of using the pulse width modulation is that analog signal can be replaced by the digital signal so that we can reduce system costs and power consumption. The effect of pulse width modulation on the vibration response was investigated in this study and the valid transformation rule was found. Then, the pulse width modulation was realized using a microprocessor and electronic circuit. The active vibration suppression was carried out by combining the positive position feedback controller and the pulse width modulation. The experimental result shows that we can replace an expensive amplifier with a pulse width modulation system thus reducing the system cost. The result also shows that the active vibration control can be achieved by the pulse width modulation technique.

A Study on the Great Principle of Pulse Diagnosis in the 『Nanjing』 (『난경(難經)』의 진맥(診脈) 대법(大法)에 관한 고찰)

  • Jang, Woochang;Kim, Yuna
    • Journal of Korean Medical classics
    • /
    • v.33 no.4
    • /
    • pp.83-105
    • /
    • 2020
  • Objectives : This paper aims to examine the system, principle, and fundamentals of the great principle of pulse diagnosis in the 『Nanjing』. Methods : The system, principle, and fundamentals of pulse diagnosis in the 『Nanjing』 were examined within the book's description framework and logical structure in light of its relationship to the 『Huangdineijing』. Previous studies that follow pulse diagnosis of 『Nanjing』 and 『Wangshuhe Maijue』 were referenced. Results & Conclusions : The structure of pulse diagnosis in the 『Nanjing』 is systematically organized under the principle of the three positions and nine indicators as the great principle to which the yinyang and five viscera pulse theories are included. The great principle of the three positions and nine indicators is consisted of a system that allows for a multiple and comprehensive interpretation wherein the theories of yinyang and five elements are interweaved within the pulse diagnosis system, which is comprised of a great principle and particular principles. The theory follows that of the three yin three yang theory of the five circuits and six qi, its principles manifesting as the three positions and nine indicators and integration of pulse and symptoms.