• Title/Summary/Keyword: Pulse studies

Search Result 474, Processing Time 0.041 seconds

A Cyclic CMOS Time-to-Digital Converter

  • Choi, Jin-Ho;Kim, Ji-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.112-115
    • /
    • 2007
  • A CMOS TDC(time-to-digital converter) is proposed which has a simple cyclic structure. The proposed TDC consists of pulse-shrinking elements, D latches and D flip-flops. The operation is based on pulse-shrinking of the input pulse. The resolution of digital output can be easily improved by increasing the number of the pulse-shrinking elements, D latches and D flip flops. The TDC performance is improved in viewpoints of power consumption and chip area. Simulation results are shown to illustrate the performance of the proposed TDC circuit.

The Effects of Sa-am Acupuncture on Radial Pulse in Healthy Human Subjects: A Comparative Study of Liver Tonifying and Sedating (간정격 및 간승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구)

  • Yuk, Dong Il;Jeon, Ju Hyun;Kim, Young Il;Kim, Jung Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.169-185
    • /
    • 2015
  • Objectives : The purpose of this study is to find the effects of Sa-am liver tonifying and sedating acupuncture on radial pulse. Methods : Sixty healthy people were divided into a liver tonifying acupuncture(LTA) group, liver sedating acupuncture(LSA) group, and control group. The LTA group and LSA group received acupuncture for 20 minutes with a supine position. The Control group took a rest without receiving acupuncture. Radial pulse was measured by three dimensional pulse imaging system(DMP-3000) at four different time points (before, right after, 30 minutes after, and 60 minutes after acupuncture). We compared the three groups and figure out determined the parameters which significantly changed after acupuncture treatment. Results : 1. Pulse period, T1/T, T4/T, (T-T4)/T, T4/(T-T4), T5/T significantly changed after acupuncture. 2. H4, pulse area, systolic pulse area, diastolic pulse area, radial augmentation index(RAI), and pulse power volume / min significantly changed after acupuncture. 3. Frequency of Fourier components, ratio of frequencies of Fourier components, magnitude of Fourier components, and ratio of magnitudes of Fourier components significantly changed after acupuncture. Conclusions : LTA and LSA have an effect on the radial pulse parameters. Further studies on radial pulse change using Sa-Am acupuncture are needed.

Hybrid Fuzzy PI-Control Scheme for Quasi Multi-Pulse Interline Power Flow Controllers Including the P-Q Decoupling Feature

  • Vural, Ahmet Mete;Bayindir, Kamil Cagatay
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.787-799
    • /
    • 2012
  • Real and reactive power flows on a transmission line interact inherently. This situation degrades power flow controller performance when independent real and reactive power flow regulation is required. In this study, a quasi multi-pulse interline power flow controller (IPFC), consisting of eight six-pulse voltage source converters (VSC) switched at the fundamental frequency is proposed to control real and reactive power flows dynamically on a transmission line in response to a sequence of set-point changes formed by unit-step reference values. It is shown that the proposed hybrid fuzzy-PI commanded IPFC shows better decoupling performance than the parameter optimized PI controllers with analytically calculated feed-forward gains for decoupling. Comparative simulation studies are carried out on a 4-machine 4-bus test power system through a number of case studies. While only the fuzzy inference of the proposed control scheme has been modeled in MATLAB, the power system, converter power circuit, control and calculation blocks have been simulated in PSCAD/EMTDC by interfacing these two packages on-line.

Meta-Analysis of the Effectiveness on Foot-Reflexo-Massage for Cancer Patients (암환자에게 적용한 발반사 마사지 중재효과의 메타분석)

  • Kim, Min-Young;Oh, Pok-Ja
    • Asian Oncology Nursing
    • /
    • v.11 no.2
    • /
    • pp.127-135
    • /
    • 2011
  • Purpose: This study was performed to analyze the characteristics and effect sizes of intervention studies on foot-reflexo-massage applied to cancer patients. Methods: For meta-analysis, a total of 159 studies were retrieved from search engines such as RISS, nanet, KISS, richis and KoreaMed. 16 studies published from 1990 to 2010 were selected based on the inclusion criteria. The data were analyzed with the RevMan 5.0 program of Cochrane library. Results: 1) The mean score of 1 implement time on foot-reflexo-massage was 25.62 minutes, the average number of days was 4.12 days, and the total number of average intervention frequency was 4.25 times. 2) Intervention studies on foot-reflexo-massage included 9 studies on anxiety (56.3%), 7 for pain (43.8%), 5 for BP/pulse (31.3%), 5 for fatigue (31.3%), 3 for nausea/vomiting (18.8%), 3 for sleep satisfaction (18.8%), and 2 for depression (12.5%). 3) The effect sizes of the intervention studies that showed higher effect size were in order, anxiety (d=-1.76), fatigue (d=-1.43), depression (d=-1.03), nausea and vomiting (d=-0.83), pain (d=-0.77), pulse rate (d=-0.61), blood pressure (d=-0.55), and sleep satisfaction (d=0.43). Conclusion: This study suggests that foot-reflexo-massage can increase sleep satisfaction, whereas decreasing blood pressure, pulse rate, anxiety, fatigue, depression, nausea, vomiting and pain.

Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system (사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae Hyeung;Li, Xiao Yu;Ha, Hyun Chul;Jung, Jae Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

A Study on the Pulse Diagnosis of the Medical Charts of Youksimanpil (의안(醫案) 『역시만필(歷試漫筆)』의 맥진(脈診) 실행(實行)에 대한 연구)

  • Jeon, Jongwook
    • Journal of Korean Medical classics
    • /
    • v.30 no.2
    • /
    • pp.59-81
    • /
    • 2017
  • Objectives : This paper studies the pulse diagnosis as found in Youksimanpil, which is a series of medical charts containing 150 diagnosis records of Yi Suki, a doctor who was active in Joseon during the 17-18th centuries. Through this effort, the paper aims to shed light on how pulse was utilized in the Korean medicine, and in process tries to reveal the essence of Korean medicine's treatment method. Methods : 60 charts where pulse method was used are selected in Youksimanpil and a table is created with them. Figures are drawn to explain four steps of pulse-sensing from the simple method to highly advanced method. Charts are presented with the corresponding original texts and their translations. With these efforts, the paper attempts to reveal the broad understanding of the doctor of Joseon period who consistently kept to the most basic principle of pulse diagnosis. Results : The efficiency of pulse diagnosis depends on the unity and simplicity in diagnosis and prescription. There were continued efforts between the doctors in Joseon to collect and compare the experiences they gained from clinical practices in order to organize their findings and form a system. These are: (1) individual pulse, (2) patternized pulse, (3) balance between left and right pulses, (4) balance between pulse and body, and (5) the doctor's extemporaneous diagnosis. In that efforts, they protect the principle of holistic diagnosis, which is one of Korean medicine's core principles. Conclusions : Thanks to the existence of medical charts that presents in detail how the texts of Donguibogam were applied in real clinical practices, today we can see Korean medicine's highly advanced synergy between textual knowledge and clinical experiences as recorded in the form of charts.

Study on the Human Influence according to RF Pulse Intensity by use Dental Implant on BRAIN MRI: Using the XFDTD Program (Brain MRI 검사 시 치아 임플란트 시술유무와 RF Pulse 세기에 따른 인체 영향에 관한 연구: XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.361-370
    • /
    • 2017
  • In the Brain MRI, RF Pulse is irradiated on the human body in order to acquire an image. At this time, a considerable part of the irradiated RF Pulse energy is absorbed as it is in our body. This will raise the temperature of the human body, but depending on the extent of exposure, it will affect the human body. The change of the SAR and the temperature of the head according to the change of the magnetic field strength is examined. And to investigate the difference in results depending on the use of dental implant. In the human head model, 64 MHz RF Pulse frequency generated from 1.5 T, 128 MHz RF Pulse frequency generated from 3.0 T, and 298 MHz RF Pulse frequency generated from 7.0 T send a frequency and experiment was performed using dental implant using the XFDTD program, we measured the SAR and body temperature changes around the head. The SAR value showed up to about 5800 times the difference at the RF Pulse frequency of 256 MHz, when with dental implant than without dental implant and as the frequency increased, the use of the dental implant increased difference in the SAR value. The change of the temperature of the head showed a temperature rise nearly 2 to 4 times when with dental implant than without dental implant. As the RF Pulse frequency increase, the SAR value increase, but the change of the temperature of the head decrease. Because of as the frequency increase, wavelength is smaller and the more the amount absorbed by the surface of the human. Physiological and biochemical studies of the human body ar necessary through studies of the presence of dental implant and the cause of reaction caused by change in the RF Pulse frequency.

Counting Method and Application of Pulse-taking on both Carotid and Wrist Pulses in Suwen·LiuJieCangXiangLun (『소문(素問)·육절장상론(六節藏象論)』의 인영(人迎)·촌구(寸口) 맥진(脈診)의 셈법과 활용에 대한 연구)

  • Jo, Hak-jun
    • Journal of Korean Medical classics
    • /
    • v.30 no.3
    • /
    • pp.77-93
    • /
    • 2017
  • Objectives : Clear and detailed analysis on Pulse-taking on both Carotid and Wrist Pulses is an absolute prerequisite if it is to be applied in real practice or its practical value proven. Methods : The original notes found in Suwen and Lingshu, their translations, and conventional studies regarding Suwen LiuJieCangXiangLun's Pulse-taking are compared and analyzed to find cases within medical texts where this method was used and to get an idea of the direction taken by the conventional study. Results : The ilsung, esung, samsung, and sasung of Carotid (or wrist pulses) refers that the pulse is one-, two-, three-, four-fold in differences. Refrainment should be practiced while comparing carotid and wrist pulses. Rather, they need to be compared with their normal states. Used by Luo Tianyi in Ming Dunasty, this method of pulse-taking was used for (radial artery) when diagnosing and treating the degree of seriousness of food injury. The measurement of maximum blood flow velocity using TCD done recently proved the validity of this pulse-taking, and it's been used for alleviating hypertension or tinnitus through acupuncture, or abating intractable diseases (around carotid). Conclusions : The obscurity of the measuring method of this pulse-taking can be resolved, and the problem which occurs while comparing carotid and wrist pulses can be solved. Even though there are differences in opinion regarding the positions when comparing the two pulses, their practical values are acknowledged since their usages in diagnosis, treatments, experiments, and researches have yielded positive results to a degree. They may not be used that often, but they are nonetheless under utilization.

The Effects of Sa-Am Acupuncture on Radial Pulse in Healthy Subjects: A Comparative Study of Large Intestine Tonifying and Sedating (대장정격 및 승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구)

  • Cho, Eun;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.31 no.3
    • /
    • pp.7-18
    • /
    • 2014
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse in healthy subjects. Methods : Sixty healthy subjects participated in this study, divided into large intestine tonifying acupuncture group, large intestine sedating acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture at Cun, Guan, and Chi in the acupuncture group and in the control group at the same time points. Results : 1. Angle of main peak and magnitude of fourier component significantly changed by integrated analysis of Cun, Guan and Chi. 2. Amplitude of H1, Pulse Power volume / min, elasticity, AIx / HR, Frequency and magnitude of fourier component significantly changed by analysis of Cun, Guan, and Chi. Conclusions : The effect of Sa-Am acupuncture with large intestine tonifying and sedating in healthy human may be observed on time, amplitude, pulse area, augmentation index and fourier components parameters. The parameters analysed in this study may be used to differentiate the effects between Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph (말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구)

  • Jeong In-cheol;Shin Tae-min;Yoon Hyung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.